Call Back Setting
Option
Address
Default
Call back setting (0 = disabled, 1 = enabled)
0972
0
Call back telephone number (see How to program a
telephone number via address programming:, page 34)
0974 – 0989 15
Domestic Telephone Number
Option
Address
Default
Domestic telephone number 1
1496 – 1511 15
Domestic telephone number 2
1512 – 1527 15
Domestic telephone number 3
1528 – 1543 15
Domestic telephone number 4
1544 – 1559 15
See How to program a telephone number via address programming:, page 34
Ring Count
Option
Address
Default
Ring count (0 = The panel does not answer any incoming
calls.
1 – 13 = Number of rings until the control panel answers.
14 = The control panel is called, the phone is allowed to
ring only twice and hangs up. After 8 seconds the control
panel is called again and answers to the first ring.
15 = The control panel is called and the phone is allowed
to ring only four times.)
0973
14
116 en | Address Programming
AMAX panel
2015.05 | 06 | F.01U.309.277
Installation Manual
Bosch Sicherheitssysteme GmbH
Содержание AMAX 4000
Страница 1: ...AMAX panel AMAX panel 2100 AMAX panel 3000 AMAX panel 3000 BE AMAX panel 4000 en Installation Manual ...
Страница 2: ......
Страница 162: ......
Страница 163: ......