Exit delay
The programming range is 0 - 255 seconds. In the mode of system arming, the keypad will
beep during exit and will make continuous long beep sound in the last 10 seconds to notify
the exit time is coming to an end.
Entry delay 1
The programming range is 0 - 255 seconds. Entry delay time starts when a delay zone 1 (zone
type 03, 04, 05, 06) is triggered in armed state.
Entry delay 2
The programming range is 0 - 255 seconds. Entry delay time starts when a delay zone 2 (zone
type 07, 08, 09, 10) is triggered in armed state.
Common Area
Area 1 can be used as a common area or an independent area. Common area ancillary acts are
as follows:
–
Only all belonged independent areas are armed, the common area can be armed
–
When a relevant ancillary area is perimeter arming, the common area will be perimeter
arming too
–
When a relevant ancillary area is disarmed, the common area will be armed
–
If any zones under common zones are in triggered or tamper status and the forced arming
is disabled, the common area cannot be armed
Keypad Indication
Keypad Alarm Tone
This option enables/disables the keypad alarm tone.
Audible Entry Enable
This option enables/disables a keypad warning tone during entry time when the system is in
STAY arm mode. If this option is enabled, a keypad warning tone occurs when the system is in
STAY arm mode and the entry time starts.
STAY Zone Alarm Indication
This option enables/disables the keypad alarm indication. If this option is enabled, information
is displayed on the keypad, when the system is in STAY arm mode.
Entry Delay Backlight on
This option enables/disables the keypad backlight during entry time. If this option is enabled,
the keypad backlight turns on when the system is in STAY arm mode and the entry time starts
and turns off when the entry time ends and no other button is pressed.
Keypad Lockout
Keypad Lock Count
The number of attempts to enter a wrong user code can be set from 1 to 15 in order to
supervise valid user access. The keypad will be locked for 3 minutes, when the number of
attempts reaches the declared value.
6.4.3
6.4.4
6.4.5
70
en | Settings
AMAX panel
2015.05 | 06 | F.01U.309.277
Installation Manual
Bosch Sicherheitssysteme GmbH