The zone fault occurs when the zone is triggered and recovers when the zone is normal. Zone
fault will occur when one of the following conditions is met:
–
For 24-hour zone, (internal) instant zone, if the forced arming option is set to allow, the
zone fault event will occur when the arming operation is executed while the zone is in
triggering status
–
When the zone is locked
–
For (internal) delay and (internal) follow zone, if they are still in triggering status at the
end of exit delay, zone fault event will occur
–
For 24-hour zone, if it is in triggering status when the bypass is cancelled, zone fault
event will occur
Fault recovery conditions:
–
Zone resumes to normal conditions
–
When the failed (internal) delay zone, (internal) instant zone and (internal) follow zone
are disarmed, the fault recovery event will occur even if the zone is still in triggering
status
Zone Bypass Report
After a manual zone bypass operation is executed, the zone is bypassed and a relevant zone
bypass report is sent. The zone bypass report will be sent at the end of exit delay time.
The zone bypass will be recovered when the system is disarmed and the zone bypass recovery
report will also be sent while disarming.
Zone Tamper Alarm
In case of zone tamper event, the tamper report will be sent. When zone tamper recovers, the
system status report will be sent.
Arming / Disarming Reporting (System)
The system disarming report is sent at the disarming command and the system arming report
is sent when the arming succeeds.
Duress Report
The duress report is sent at the disarming command. The duress report will not be sent in the
operation of arming, but sent with ordinary disarming report. The duress report has no
corresponding alarm recovery report.
Key Switch Arming
Sends system arming report when the transient key switch or locking key switch is used to
arm areas.
Quick Arming
Sends system arming report when the keypad is used for quick arming.
Telephone Arming
Sends system arming report when the telephone is used for arming of the panel.
Telephone arming is only available when there is Area 1 and 1 Area alternatively in the system.
RPC Arming
Sends system arming report when the remote PC is used to arm areas through network or
telephone connection.
Arming / Disarming Reporting (Perimeter)
The perimeter disarming report is sent at the disarming command and the perimeter arming
report is sent when the arming succeeds.
Quick Arming
Sends perimeter arming report when the keypad is used for quick arming.