(76 mm.)
3 in.
3 in.
3 in.
(76 mm.)
Back wall
Side wall
fig. Nº4
fig. Nº5
SELECT A LOCATION BETWEEN
FRAMING MEMBRES FOR THE
OUTSIDE AIR HOLE
WALL
COVER
PLATE
SEAL THE AREA AROUND
THE TUBE TO PREVENT AIR
FROM ENTERING THE WALL
SEAL THE
VENT WITH
SILICONE
2" FLEX DUCT
NON COMBUSTIBLE
CUT A MINIMUN 2"
DIAMETER HOLE IN
THE WALL
RAIN
HOOD WITH
RODENT
SCREEN
COMBUSTION AIR SUPPLY
DO NOT USE MAKESHIFT MATERIALS OR COMPROMISES IN THE
INSTALLATION OF THIS UNIT.
For a mobile home installation the stove must be
connected. To an outside source of combustion air. A
2” inside diameter metallic pipe, either flexible or rigid,
may be attached to the inlet at the stove’srear (refer to
fig. Nº5). A rodent guard (minimum 1/4” wire mesh)
/wind hood must be used at the terminus. All
connections must be secured and airtight by either using
the appropriately sized hose clamp and/or UL-181-AP
foil tape.
INSTALL VENT WITH CLEARANCES SPECIFIED BY
THE VENT MANUFACTURER.
OWNER´S MANUAL
-7-
(76 mm.)