fig. Nº8a
fig. Nº8b
Vertically Into Existing Masonry Fireplace
NOTE:
Follow L-Vent chimney manufacturer’s instructions.
•
Have the masonry chimney inspected by a qualified chimney sweep or installer to determine its structural condition.
•
You will need a pipe length equal to the chimney height from the hearth. If outside combustion air is to be used, you will need a pipe
length equal to the chimney height plus 18 inches.
•
Install a blanking plate and the chimney pipe, and if used the outside air pipe.
24" MIN
ATTIC
INSULATION
SHIELD
CEILING
SUPPORT/
FIRESTOP
SPACER
PIPE
ADAPTER
TEE WITH
CLEAN-OUT
ADAPTER
24" MIN
ATTIC
INSULATION
SHIELD
CEILING
SUPPORT/
FIRESTOP
SPACER
PIPE
ADAPTER
TEE WITH
CLEAN-OUT
ADAPTER
Attach the L-Vent adapter, a section of pipe and clean out tee, making sure the clean-out tee is centered in the chimney flue area. Use RTV,
metallic tape, and a minimum of three self-taping screws at all joint connections to ensure a tight seal.
Install and seal the top plate from step 3 with non-hardening mastic. Slip the storm collar over the pipe, and while holding
the pipe at the proper elevation, affix the collar with a minimum of three 1/4” stainless steel sheet metal screws. Seal all
joints and seams around the collar.
Connect the horizontal pipe by pushing it through the hole in the masonry and lining it up with the branch in the tee.
Push the pipe into the tee while twisting it to lock it into the tee.
If desired, once the horizontal pipe is in place, the space between the pipe and masonry may be filled with high-temperature
grout.
Install the trim collar. An adjustable pipe length and adapter may be needed to finish the connection to the stove.
OWNER´S MANUAL
-11-
(Refer to fig. Nº9)