I. Safety requirements and precautions

•  Device should be powered from the mains with an alternating current of 220 - 240V.
•  Internal installation must have a 16A fuse.
•  Device must be unconditionally connected to the socket outlet with earthing contact.
•  If  the  power  cord  or  plug  is  damaged,  to  avoid  danger,  it  should  be  replaced  at  the 

manufacturer, or by a specialised repair shop, or by a qualified electrician.

•  Before starting cleaning the device, disconnect the power supply.
•  Smoke generator can only be connected to the power supply after it has been installed in 

the device adapted to its assembly.

•  If you use an electric extension cord, its current load should be at least as much as the rated 

load of the device.

•  If you use an electric extension cord, make sure it has an efficient earthing contact (ground).
•  Lay the power cords in such a way that they are not crushed, prevent it against pulling or 

stumbling over by children.

•  If you use electric extension cords, they must be adapted for outdoor use and should be 

labelled "for outdoor use".

•  Power cords of the device should be arranged in such a way that they are not in contact with 

hot parts of the housing.

•  The  smoker  is  intended  for  outdoor  use  but  it  must  not  be  exposed  to  atmospheric 

precipitation and strong gusts of wind. The optimal solution is to work in roofed, sheltered 

and, at the same time, ventilated places.

•  Do  not  use  the  device  in  closed  rooms,  in  case  of  use  under  a  roof  ensure  sufficient 

ventilation.

•  Do  not  use  the  device  near  gasoline  or  other  flammable  liquids,  gases  or  places  where 

flammable vapours may be present.

•  Do not use the device near flammable objects.
•  Do not use the device when it comes in contact with parts, objects made of materials not 

resistant to high temperature.

•  It is recommended to put an extinguisher near the device. Information on the proper size 

and type of the extinguisher can be obtained from the local authorities.

•  Do not connect the device until it has been fully assembled.
•  Do  not  move  the  device  before  removing  all  moving  objects  inside  the  smoker  and  the 

smoke generator.

•  Do not connect the device to the chimney, ventilation grille or other wires that may cause 

forced air draft.

 NOTE - LOCATION

 NOTE - ELECTRICITY

Содержание BBD-150

Страница 1: ...g the device read the instructions MANUAL FOR SMOKERS BBD 70 BBD 150 BBDS 70 BBDS 150 UWD 70 UWD 150 UWDS 70 UWDS 150 SMOKE GENERATOR GD 01 GDS 01 I Safety requirements and precautions II Terms of use III Technical parameters IV Composition of the set V Construction and description of the operation VI Operation of the electronic control panel VII Assembly and installation VIII First start IX Maint...

Страница 2: ...Page 2 Dear user Thank you for choosing the Borniak device ...

Страница 3: ...should be labelled for outdoor use Power cords of the device should be arranged in such a way that they are not in contact with hot parts of the housing The smoker is intended for outdoor use but it must not be exposed to atmospheric precipitation and strong gusts of wind The optimal solution is to work in roofed sheltered and at the same time ventilated places Do not use the device in closed room...

Страница 4: ...urer may result in injury or damage to the device for which the manufacturer is not responsible Be careful with sharp edges when assembling and disassembling the device Do not use the device contrary to its intended use The device is intended for home use Do not leave the device switched on after finishing smoking The device should be inaccessible to animals Do not allow children to use the device...

Страница 5: ...dren or animals Do not touch hot components to avoid burns it is recommended to use gloves protecting against high temperature Do not use the packaging to cover the device It is mandatory to connect the device to a grounded electrical outlet an extension cord Protect against rain and water access After each use switch off the device from mains power supply if it is not used Thoroughly clean the sm...

Страница 6: ...apacity 70L 70L 150L 150L 2L Maximum temperature 120 C 150 C 120 C 150 C The Degree of the housing tightness IP20 TECHNICAL PARAMETERS OF THE SMOKER Width mm 440 540 625 530 630 715 355 Depth mm 350 400 475 520 180 Hheight mm 820 1040 991 1211 250 OVERALL DIMENSIONS EXTERNAL Width mm 400 490 Depth mm 300 420 Height mm 580 755 DIMENSIONS OF THE CHAMBER INTERNAL dimensions of a smoker assembled with...

Страница 7: ...ter bowl 2 pcs A chimney with an air damper Illustrative drawings do not reflect the actual dimensions of the parts the plug type depends on the distribution country type of product and quantity dependent on the set Power cord EU C13 GN tray only BBQ version Crossbars for hanging 3 pcs A 10 1 A A cover for the generator Power cord C13 C14 Wood chips A chimney with an air damper Smoker rack Smoker ...

Страница 8: ...eeder 7 starts to rotate at the same time the burner 6 begins to heat The feeder uniformly transports chips from the storage tank 2 to the burner where they start to smoulder Smouldering chips are pushed through the entire length of the burner 6 where at the end they fall into a container filled with water 8 9 7 6 4 1 5 3 LEFT RIGHT 2 10 Using a smoker does not require any special skills and the p...

Страница 9: ...one is placed under the generator burner the other under the drip tray opening 4 The first bowl is used to extinguish the falling chips the second one is used to collect the juices from smoked meats The ambient temperature and wind have a large impact on the operating conditions of the device In unfavourable atmospheric conditions the chamber heating time may increase It is advisable to use an ind...

Страница 10: ...locking plates DIGITAL CONTROL PANEL The panel is used to control the temperature in the chamber We start the smoker with the switch 2 On the controller 1 see p 11 set the desired temperature With the connector 7 the controller controls the burner in the smoker With the switch 3 we activate the smoke generator connected to the outlet 6 4 FRONT BACK LEFT RIGHT 5 6 7 1 2 3 8 ...

Страница 11: ...e display 6 from the set temperature to the burner activation frequency in percent e g value 50 means that the burner is on for the same time as it is off FRONT 1 2 3 4 1 SET confirmation button 2 AT setting auto tuning 3 value increase change button 4 value reduction change button 5 PV current temperature in the chamber 6 SV set temperature frequency of the burner activation CONTROLLER DISPLAY 6 ...

Страница 12: ...tallation 1 After taking out of the carton remove unnecessary packaging and elements protecting the product and read the instructions 2 Screw two handles to carry the device 3 Screw the handle to open the door Wsunąć sunąć Wsunąć ...

Страница 13: ...moker Tilt the generator slightly to put it on the latches 6 Insert the chimney into the hole at the top of the smoker Pay attention to the correct position of the throttle valve 7 Insert the condenser under the chimney 8 Insert the drip tray onto the bottom rack 9 Mount the electronic control panel see the description p 14 Wsunąć Wkręci N a ło ż y ć i z a c z e p ić Wsunąć Wkręcić Wsunąć i dokręc...

Страница 14: ...ry 2 4 hours Connect the generator and the smoker to 230V mains with protective grounding Switch to start the smoke generator and the smoking unit on the electronic panel set the temperature to approx 80 C see Operation of the electronic control panel Heat the smoker for about 2 hours This will reduce technological odours and ensure initial flavouring of the device After heating you can start the ...

Страница 15: ...wipe them gently with a damp cloth The shutter and the bowl in which fat and ash are collected must be kept clean because excess fat may ignite NOTE When smoking excess fat falling very fat products control on the shutter it must be removed unconditionally NOTE During the operation of the device carbon deposit forms on the part of the sawdust feeder It should be removed after 8 hours of the genera...

Страница 16: ...the smoke generator burner Do not connect the smoker chimney outlet to chimneys ventilation shafts or other extensions of the smoke outlet due to the possibility of producing draft in the smoker which can cause wood chips to ignite The only way that is acceptable for extending the smoke outlet is to apply a hood over the smoker so that smoke can be extracted from the smoker at its own speed Igniti...

Страница 17: ...ies in its original packaging 6 When sending in your defective appliance for service a valid Warranty Card without any traces of changes or interference must be included 7 Damage resulting from events such as lightning strike power surge in power lines mechanical impacts fires flooding or other uncontrollable events beyond the Seller s control are not covered by this warranty 8 The User shall deli...

Отзывы: