XI. Warranty card

This  warranty  is  effective  for  24  months  from  the  date  of  purchase.  The  warranty  as 

described herein shall only apply in the territory of the Republic of Poland.

TERMS OF WARRANTY:

1. ZUT BORNIAK guarantees the user efficient operation of the appliance provided its proper 

installation, maintenance and operation, in accordance with the guidelines of this MANUAL.

2. ZUT  BORNIAK  takes  responsibility  for  manufacturer's  defects  (i.e.  in  material  or 

workmanship) of the appliance for 24 months from the date of its selling. 

3. The defects of products which shall arise during the warranty period will be removed in the 

time not longer than 30 days from the day of returning it to the manufacturer.

4. The warranty flows only to the Buyer, i.e. a natural person, who purchases a moveable item 

for a purpose different than conducting business activities or any professional activities. 

(Journal of Laws of 2002, No 141, item 1176). 

5. The  defective  appliance  must  be  returned  with  its  standard  accessories,  in  its  original 

packaging. 

6. When sending in your defective appliance for service, a valid Warranty Card, without any 

traces of changes or interference, must be included. 

7. Damage  resulting  from  events  such  as:  lightning  strike,  power  surge  in  power  lines, 

mechanical  impacts,  fires,  flooding  or  other  uncontrollable  events  beyond  the  Seller's 

control, are not covered by this warranty. 

8. The User shall deliver the defective product for service repair purposes at their own expense. 

After the repair, the appliance shall be returned to its owner at the Manufacturer's expense. 

9. It is recommended to contact the Manufacturer before sending in the defective appliance. 
10. While  sending  the  appliance  to  the  Manufacturer,  the  User  must  include  their  contact 

details, the return address, as well as a short description of the defect.

11. Liability of the Manufacturer is limited to the amount equal to the price of the defective 

product. 

12. Damages and missing goods in the case of orders delivered by Poczta Polska or courier 

companies  shall  be  dealt  with  only  based  on  the  report  drawn  up  by  the  courier  while 

delivering the parcel. 

Date of sale:

Proof of purchase No:

Seller’s signature:

Stamp:

Device serial number:

Notes:

Содержание BBD-150

Страница 1: ...g the device read the instructions MANUAL FOR SMOKERS BBD 70 BBD 150 BBDS 70 BBDS 150 UWD 70 UWD 150 UWDS 70 UWDS 150 SMOKE GENERATOR GD 01 GDS 01 I Safety requirements and precautions II Terms of use III Technical parameters IV Composition of the set V Construction and description of the operation VI Operation of the electronic control panel VII Assembly and installation VIII First start IX Maint...

Страница 2: ...Page 2 Dear user Thank you for choosing the Borniak device ...

Страница 3: ...should be labelled for outdoor use Power cords of the device should be arranged in such a way that they are not in contact with hot parts of the housing The smoker is intended for outdoor use but it must not be exposed to atmospheric precipitation and strong gusts of wind The optimal solution is to work in roofed sheltered and at the same time ventilated places Do not use the device in closed room...

Страница 4: ...urer may result in injury or damage to the device for which the manufacturer is not responsible Be careful with sharp edges when assembling and disassembling the device Do not use the device contrary to its intended use The device is intended for home use Do not leave the device switched on after finishing smoking The device should be inaccessible to animals Do not allow children to use the device...

Страница 5: ...dren or animals Do not touch hot components to avoid burns it is recommended to use gloves protecting against high temperature Do not use the packaging to cover the device It is mandatory to connect the device to a grounded electrical outlet an extension cord Protect against rain and water access After each use switch off the device from mains power supply if it is not used Thoroughly clean the sm...

Страница 6: ...apacity 70L 70L 150L 150L 2L Maximum temperature 120 C 150 C 120 C 150 C The Degree of the housing tightness IP20 TECHNICAL PARAMETERS OF THE SMOKER Width mm 440 540 625 530 630 715 355 Depth mm 350 400 475 520 180 Hheight mm 820 1040 991 1211 250 OVERALL DIMENSIONS EXTERNAL Width mm 400 490 Depth mm 300 420 Height mm 580 755 DIMENSIONS OF THE CHAMBER INTERNAL dimensions of a smoker assembled with...

Страница 7: ...ter bowl 2 pcs A chimney with an air damper Illustrative drawings do not reflect the actual dimensions of the parts the plug type depends on the distribution country type of product and quantity dependent on the set Power cord EU C13 GN tray only BBQ version Crossbars for hanging 3 pcs A 10 1 A A cover for the generator Power cord C13 C14 Wood chips A chimney with an air damper Smoker rack Smoker ...

Страница 8: ...eeder 7 starts to rotate at the same time the burner 6 begins to heat The feeder uniformly transports chips from the storage tank 2 to the burner where they start to smoulder Smouldering chips are pushed through the entire length of the burner 6 where at the end they fall into a container filled with water 8 9 7 6 4 1 5 3 LEFT RIGHT 2 10 Using a smoker does not require any special skills and the p...

Страница 9: ...one is placed under the generator burner the other under the drip tray opening 4 The first bowl is used to extinguish the falling chips the second one is used to collect the juices from smoked meats The ambient temperature and wind have a large impact on the operating conditions of the device In unfavourable atmospheric conditions the chamber heating time may increase It is advisable to use an ind...

Страница 10: ...locking plates DIGITAL CONTROL PANEL The panel is used to control the temperature in the chamber We start the smoker with the switch 2 On the controller 1 see p 11 set the desired temperature With the connector 7 the controller controls the burner in the smoker With the switch 3 we activate the smoke generator connected to the outlet 6 4 FRONT BACK LEFT RIGHT 5 6 7 1 2 3 8 ...

Страница 11: ...e display 6 from the set temperature to the burner activation frequency in percent e g value 50 means that the burner is on for the same time as it is off FRONT 1 2 3 4 1 SET confirmation button 2 AT setting auto tuning 3 value increase change button 4 value reduction change button 5 PV current temperature in the chamber 6 SV set temperature frequency of the burner activation CONTROLLER DISPLAY 6 ...

Страница 12: ...tallation 1 After taking out of the carton remove unnecessary packaging and elements protecting the product and read the instructions 2 Screw two handles to carry the device 3 Screw the handle to open the door Wsunąć sunąć Wsunąć ...

Страница 13: ...moker Tilt the generator slightly to put it on the latches 6 Insert the chimney into the hole at the top of the smoker Pay attention to the correct position of the throttle valve 7 Insert the condenser under the chimney 8 Insert the drip tray onto the bottom rack 9 Mount the electronic control panel see the description p 14 Wsunąć Wkręci N a ło ż y ć i z a c z e p ić Wsunąć Wkręcić Wsunąć i dokręc...

Страница 14: ...ry 2 4 hours Connect the generator and the smoker to 230V mains with protective grounding Switch to start the smoke generator and the smoking unit on the electronic panel set the temperature to approx 80 C see Operation of the electronic control panel Heat the smoker for about 2 hours This will reduce technological odours and ensure initial flavouring of the device After heating you can start the ...

Страница 15: ...wipe them gently with a damp cloth The shutter and the bowl in which fat and ash are collected must be kept clean because excess fat may ignite NOTE When smoking excess fat falling very fat products control on the shutter it must be removed unconditionally NOTE During the operation of the device carbon deposit forms on the part of the sawdust feeder It should be removed after 8 hours of the genera...

Страница 16: ...the smoke generator burner Do not connect the smoker chimney outlet to chimneys ventilation shafts or other extensions of the smoke outlet due to the possibility of producing draft in the smoker which can cause wood chips to ignite The only way that is acceptable for extending the smoke outlet is to apply a hood over the smoker so that smoke can be extracted from the smoker at its own speed Igniti...

Страница 17: ...ies in its original packaging 6 When sending in your defective appliance for service a valid Warranty Card without any traces of changes or interference must be included 7 Damage resulting from events such as lightning strike power surge in power lines mechanical impacts fires flooding or other uncontrollable events beyond the Seller s control are not covered by this warranty 8 The User shall deli...

Отзывы: