74
BONMET motion GmbH/www.bonmet.com/www.bonmet.de
R-21
Parameter
The current speed value
Modbus address
0x1C70
Unit
2
−2
Rpm
Range
-
Default
-
CANbus object
-
Attrib
RO
Control mode
:
All
Details
:
The corresponding physical quantity of data is the current actual speed, the unit is
2
−2
Rpm. Data format is _IQ2.
R-22
Parameter
The current high bit position value
Modbus address
0x1C71
Unit
Pulse
Range
-
Default
-
CANbus object
-
Attrib
RO
R-23
Parameter
The current low bit position value
Modbus address
0x1C72
Unit
Pulse
Range
-
Default
-
CANbus object
-
Attrib
RO
Control mode
:
All
Details
:
The corresponding physical quantity of data is the motor position, the unit is pulse. Data format is _IQ0, directly spliced by
(H, L) to form a 32-bit position command
R-24
Parameter
Torque error value
Modbus address
0x1C73
Unit
A
Range
-
Default
-
CANbus object
-
Attrib
RO
Control mode
:
All
Details
:
The corresponding physical quantities of data is the difference between torque command and actual torque (Q-axis current),
the units is Amps. Data format is _IQ7
R-25
Parameter
Speed error value
Modbus address
0x1C74
Unit
2
−2
Rpm
Range
-
Default
-
CANbus object
-
Attrib
RO
Control mode
:
All
Details
:
The corresponding physical quantities of data is the difference between speed command and actual speed, the units is
2
−2
Rpm. Data format is _IQ2.
R-26
Parameter
High bit position error value
Modbus address
0x1C75
Unit
Pulse
Range
-
Default
-
CANbus object
-
Attrib
RO
R-27
Parameter
Low bit position error value
Modbus address
0x1C76
Unit
Pulse
Range
-
Default
-
CANbus object
-
Attrib
RO
Control mode
:
All
Details
:
The corresponding physical quantities of data is the difference between position command and actual position, the units is
pulse. Data format is _IQ0, directly spliced by (H, L) to form a 32-bit position command.
R-28
Parameter
Torque command
Modbus address
0x1C77
Unit
A
Range
-
Default
-
CANbus object
-
Attrib
RO
Control mode
:
All
Details
:
The corresponding physical quantities of data is the Q-axis current command, the units is Amps
。
Data format is _IQ7.
Example
:
Please refer to R-4.