13
BONMET motion GmbH/www.bonmet.com/www.bonmet.de
3.5
Communication Connector(CN3)
Serial-line terminal plug CN3
■
RS-232
Termina
l
number
Name
Function
Symbol
Description
3
Receive data
RXD
Receive data signal.
5
Transmit data
TXD
Transmit data signal.
1
GND
GND
Inhibit signal earth.
■
RS-485
Termina
l
number
Name
Function
Symbol
Description
7
Difference signal Data+
Data+
Data+ terminal
4
Difference signal Data-
Data-
Data- terminal
8
GND
GND
Inhibit signal earth.
Chapter 4 Operation
4.1
Operation steps
Item
Content
Reference
Installation
Please keep the motor shaft in a non-connection state, do not connect the motor
with mechanical system for servo action confirmation at first.
Chapter 2
↓
Wiring
Connect servo drive with power and peripheral device
Chapter 3
↓
Preparation before
operation
Please confirm all the necessary items before turn on the power. And check if
there is any alarm.
Chapter 4
↓
Action confirmation
Operate in speed mode to test the servo drive and servo motor without any load
on the shaft.
Chapter 4
↓
Parameters settings
Set parameters according to terms of use.
Chapter 5
↓
Trial operation
Connect motor with mechanical systems
,
turn on the power, and check whether
protective functions (such as emergency stop and stroke limit) are working.
Check operation at both low speed and high speed.
—
3
1
2
4
5
6
7
8
Содержание SDL10A
Страница 1: ...User Manual For SD Series Smart Accurate ...