18
BONMET motion GmbH/www.bonmet.com/www.bonmet.de
2.
Running curve monitoring function
―Random Capture‖ menu is for the running curve monitoring function, customers can check the current loop
curve, speed loop curve and position loop curve.
4.2.5
Config function
There are two items ―Motor Config…‖ and ―Logic I/O Config…‖ under the ―Config‖ menu.
The “Aux Encoder
Config…” item DOES NOT open to customers.
1.
Motor parameters adaptive function
⑴
Click ―Basic Information…‖ and the following dialog will appear:
⑵
Fill in the basic data (please don‘t fill in other parameters)
Item
Function
Rated Current(A)
Motor nominal current
Rs
(
ohm
)
Phase resistance
Ls
(
mH
)
Phase inductance
Ke
(
V/Krpm
)
Back EMF
Note
:
This operation must be carried out by electrical engineer and the above parameters must be effective,
otherwise it would cause mistake or damage.
⑶
Adaption
Click ―Auto Match‖ to start the adaption operation, as the following dialog appears, select the right direction(face
the motor shaft, ―CCW direction‖ indicates counterclockwise direction and ―CW direction‖ indicates clockwise0
direction), and then click ―OK‖.
Содержание SDL10A