Pilot will not
light using a
match
OR
Main burner
will not light
after pilot is lit
No gas flow
Check if gas cylinder is empty. If yes, replace.
Regulator is not fully connected
to the tank
Check LP tank connection.
Gas flow is obstructed
Check hose for bends or kinks
Spider webs or insect nest in the
venturi (end of burner tube) or
pilot housing
Clean the venturi or pilot housing
Burner ports are clogged
Insert an opened paperclip into each of the
burner ports to clean them. Ensure the
appliance is off and all parts are cooled before
attempting to clean the burner ports
Appliance emits
a lot of black
smoke when lit
Flame is obstructed at burner
ports
Make sure all the gas burner ports are free of
any lava rocks or debris to allow the gas to
flow freely.
Regulator hose is pinched
Check the regulator hose for bends or kinks
Sudden drop
in gas flow
No gas flow
Check if gas cylinder is empty. If yes, replace.
Excess flow safety valve has
been activated
Turn the control knob to "OFF", close the LP tank
valve and disconnect the regulator from the tank.
Turn the control knob to "HIGH". Wait 1 minute.
Turn the control knob to "OFF". Reconnect reg-
ulator to LP tank. Open tank valve slowly. Light
appliance as indicated in the "To Light" section.
Flame blow out
High or gusting winds
Increase flame to "High"
No gas flow
Check if gas cylinder is empty. If yes, replace.
Excess flow safety valve has
been activated
See "Sudden drop in gas flow" above
Irregular flame
pattern or flame
does not come
out of the entire
length of the
burner
Burner ports are clogged
See "Burner will not light using a match"
above.