ILLUMINATION CAUSES
Table 4-1 lists the 10 and 8 channel annun-
ciators and the individual system caution an-
nunciators, shows their color, and gives the
cause for their illumination. The 10 and 8
channel annunciator panel locations are shown
in the Annunciator Section.
Table 4-1. CAUTION ANNUNCIATORS
Indicated wing anti-ice system has failed.
The wing anti-ice sensor has failed.
Indicated cowl anti-ice system has failed.
Indicated windshield heat has failed.
The ADS heater has failed.
Indicated pitot heat has failed.
Indicated ice detector system has failed.
HTR
FAIL
DUCT
FAIL
SENSOR
FAIL
ANNUNCIATOR
ASSOCIATED
ANNUNCIATOR
CAUSE FOR ILLUMINATION
R FAIL
L FAIL
FAIL
FAIL
PITOT
HEAT
PITOT
HEAT
ON
FAIL
ON
FAIL
The APU fuel pump is inoperative.
The APU/APU generator adapter oil pressure is low.
The APU LCV has failed to close.
LO
PRESS
HI
TEMP
SOV
CLOSED
PUMP
INOP
OPEN
FAILED
TEST
NO HT
ANTI-ICE
APU
The APU/APU generator adapter oil temperature is excessive.