46
Manually adding serial control cameras
On the controller, press the Setup button to go into
menu:
1.
Go to CAMERA SETTING
2.
With the cursor on the Camera Selection,
use the Zoom Speed dial to select which
camera slot to assign a camera.
3.
If the camera has Visca address set to 0 or
1, set the CAM ID to 001.
4.
Set the camera Title if desired.
5.
Set Protocol:
a.
Each camera can be configured to be controlled using any of the following protocols:
•
VISCA
•
PELCO-D
•
PELCO-P
•
ONVIF
•
VISCAIP (VISCA over IP)
•
CGI*
Select VISCA, the Baud Rate Setting screen
will appear. Use the Zoom Speed dial to set
the baud rate.
6.
Click the Zoom Speed dial to save, and
then exit this menu.
Control the Camera via Serial RS422
Once the controller and cameras are set for serial control, on the controller side:
•
Press the camera ID then press the CAM button, the camera config info will be shown on the LED display with
OK, indicating successful connection. The camera is ready to be controlled.
•
Use Joystick to control the camera
>CAMERA SETTING
KEYBOARD SETTING
EXIT
Main Setup Menu
>CAM001
Title: -
Protocol: VISCA
Exit
Camera Setting Menu
CAM001
Title: -
>Protocol: VISCA
Exit
Camera Setting Menu
>Baud Rate: 9600
Exit
Baud Rate Setting