14
ORS Infrared Sensor
Installation
Sensor Wiring
The sensor connects to the coaxial cable using F-connectors. Route the coaxial cable over the ceiling from the IR sensor location
to the location of the ORB35 unit. Connect the cable with the sensorʼs pigtail connector. For distances longer than the included
coaxial cable, a user-supplied cable can be connected to the included coaxial cable using a double ended F-connector. A good
quality 75-ohm coaxial should be used for the extension cable. A maximum cable length of 100 feet (30 meters) is recommended.
Sensor Mounting
The IR sensor is typically installed on the ceiling of the room. The sensor includes quick mounting brackets for use on suspended
ceiling T-rails. Mounting holes for use with screws and wall anchors are also provided. Refer to the instructions supplied with the
sensor for specific mounting instructions.
Typically the IR sensor is mounted in the center of the area where the instructor is most likely to be while using the system. Odd
shaped rooms or rooms with elements that may obstruct the sensorʼs ability to “see” the OMX1, may need additional sensors for
optimal coverage. It is important to keep the sensor away from areas subject to bright illumination by sunlight. Either direct or reflected
bright sunlight can overwhelm the sensor and make it less sensitive to the IR signals coming from the OMX1.
ORS2
CEILING
BRACKET
RUBBER
WASHER
NYLON
SCREW
STEP 1
ORS2
BRACKET
T-BAR
ORS2
HEAD-ON VIEW
TILE
TILE
BRACKET
STEP 2
TWIST ORS2
ONTO T-BAR
ORS2
T-BAR
COAXIAL
CABLE
CONNECT
OPTION 1:
ATTACH TO CEILING TILE T-BAR RAIL
OPTION 2:
ATTACH TO HARD SURFACES
NOTE:
FOR MOST UP-TO-DATE SENSOR
INSTALLATION INSTRUCTIONS, REFER TO
THE MANUAL INCLUDED WITH SENSOR.