[MBA_NKBD_EN] Rev.: 10/2015
17
No liability accepted for translation or printing errors. Subject to changes in dimensions, weights and other technical data.
All rights reserved. Modifications, reprints and photomechanical reproduction, even in extract from, require the express permission of BOGA GmbH, Werkstraße 16, D-59494 Soest.
BOGA GmbH
• Werkstraße 16 • D-59494 Soest • Fon: +49 2921 96943-0 • Fax: +49 2921 96943-29 • [email protected] • www.airwin.net
10.2 Establishing and detaching connections with connectors
The connectors provide durable, safe and watertight connections between tube and connecting ele-
ment. The tube is simply inserted by hand. The retaining element holds the tube safely without
pressing it or decreasing the flow.
Establishing the connection
Cut tube squarely and free of burrs.
Make sure that the tube has no sharp edges,
longitudinal grooves or other damage.
fig. 13 - Establishing the connection
Connection is stable prior to sealing
Insert the tube up to the stop.
The supporting element holds the tube in the
connector. With the help of the O-ring,
a tight connection is established.
fig. 14 - Insert tube
Check the connection by pulling towards the
opposite side
By pulling towards the opposite side check
whether the tube was safely inserted.
fig. 15 - Check connection
Detaching the connection
The tube can be detached by pushing back the
supporting element.
fig. 16 - Detaching the connection
remove
tube
press back
support element
press back
support element
support element
stainless steel teeth