Parameter
Number
Description
Default
Value
Range
1
Enables tank sensor 1.
1
0 – 1
2
Enables tank sensor 2.
1
0 – 1
3
Enables tank sensor 3
0
0 – 1
4
Enables waste water sensor 4
0
0 – 1
5
Temperature units select, °C or °F
(initially °C)
0
0 – 1
6
Rated Capacity – The actual rated
capacity of the battery in Ah
100
7 – 999
7
Low voltage alarm threshold, V
11
10.5 – 12.5
8
Battery operating temperature – Initially
°C
25°C
77°F
-20 – 50°C
-4 – 122°F
9
Total Cycles – An estimate of the total
number of charge discharge cycles
(Read Only)
0
0 – 999
Table 1: Setup Parameters
Tank Sensors
If a tank sensor is enabled but no tank sensor is connected, the tank level will be
shown as either full or empty, depending on whether the pump switch is on or off.
By disabling the sensor the tank level is always shown empty.
Temperature Units Select
This parameter sets the temperature units to either °C or °F. Setting it to a 1 will
convert the temperature to °F. Default units is °C.
Rated Capacity
This is the actual capacity of the battery in Amp-hours.
When a new battery is fitted, set this to the nominal battery capacity (as marked
on the battery); doing this will assist the software in determining the actual
capacity.
Low Voltage Alarm Threshold
This threshold sets the voltage at which the low voltage indicator starts blinking.
This is user settable and is used to indicate the desired low voltage.
Battery Operating Temperature
This is the typical operating temperature of the battery. This helps improve the
12
10
Table 1: Setup Parameters
Tank Sensors
If a tank sensor is enabled but no tank sensor is connected, the tank level will be shown as
either full or empty, depending on whether the pump switch is on or off. By disabling the
sensor the tank level is always shown empty.
Temperature Units Select
This parameter sets the temperature units to either °C or °F. Setting it to a 1 will convert the
temperature to °F. Default units is °C.
Rated Capacity
This is the actual capacity of the battery in Amp-hours. When a new battery is fitted, set this
to the nominal battery capacity (as marked on the battery); doing this will assist the software in
determining the actual capacity.
Low Voltage Alarm Threshold
This threshold sets the voltage at which the low voltage indicator starts blinking.
This is user settable and is used to indicate the desired low voltage.
Battery Operating Threshold
This is the typical operating temperature of the battery. This helps improve the accuracy of the
predicted time remaining readout . This can either be in °C or °F depending on parameter 5.