background image

 

 

V1.1 

SmartBus P900-TI6N USER MANUAL 

Contents 

1.0  INTRODUCTION .................................................................................................................................. 2

 

2.0  TESTING ................................................................................................................................................ 2

 

3.0  LIMITATIONS ...................................................................................................................................... 2

 

4.0  GLOSSARY ............................................................................................................................................ 2

 

5.0  SUMMARY OF OPERATION ............................................................................................................. 2

 

6.0  TELEPHONY CONTROL DIAGRAM ............................................................................................... 2

 

7.0  LED AND LCD KEYPAD MODEL ..................................................................................................... 2

 

8.0  LED KEYPAD ........................................................................................................................................ 2

 

8.1  UNDERSTAND YOUR KEYPAD INDICATORS .................................................................. 2

 

8.2  USER PROGRAMMING SUMMARY DIAGRAM ................................................................ 2

 

8.3  USER PROGRAMMING SUMMARY TABLE ....................................................................... 2

 

8.4  ARMING THE SYSTEM .......................................................................................................... 2

 

8.4.1  AWAY ARMING .................................................................................................................... 2

 

8.4.2  DAY ARMING....................................................................................................................... 2

 

8.4.3  NIGHT ARMING .................................................................................................................. 2

 

8.4.4  FORCE ARMING ................................................................................................................. 2

 

8.4.5  HOLIDAY ARMING ............................................................................................................. 2

 

8.4.6  AUTO TIMER ARMING ....................................................................................................... 2

 

8.4.7  TELEPHONE REMOTE ARMING ....................................................................................... 2

 

8.4.8  REMOTE CONTROL ARMING (OPTIONAL) ..................................................................... 2

 

8.5  DISARMING THE SYSTEM ................................................................................................... 2

 

8.5.1  KEYPAD DISARMING ......................................................................................................... 2

 

8.5.2  AUTO TIMER DISARMING ................................................................................................. 2

 

8.5.3  TELEPHONE REMOTE DISARMING ................................................................................. 2

 

8.5.4  REMOTE CONTROL DISARMING (OPTIONAL) ............................................................... 2

 

8.6  TURN ON/OFF HOME AUTOMATION POINT .................................................................... 2

 

8.7  BYPASS ZONE ......................................................................................................................... 2

 

8.8  UN-BYPASS ZONE .................................................................................................................. 2

 

8.9  VIEW SYSTEM TROUBLE ..................................................................................................... 2

 

8.10  VIEW ALARM MEMORY ..................................................................................................... 2

 

8.11  CHIME MODE ........................................................................................................................ 2

 

8.12  EMERGENCY SITUATION .................................................................................................. 2

 

8.13  PARTITIONING THE SYSTEM ............................................................................................ 2

 

8.14  ARMING A PARTITIONED SYSTEM ................................................................................. 2

 

8.14.1  AWAY ARMING 2 PARTITIONS SIMULTANEOUSLY ...................................................... 2

 

8.14.2  AWAY ARMING EITHER 1 PARTITION ........................................................................... 2

 

8.14.3  FASTKEY AWAY ARMING EITHER 1 PARTITION .......................................................... 2

 

8.14.4  PARTITION DAY ARMING ................................................................................................ 2

 

8.14.5  PARTITION NIGHT ARMING ........................................................................................... 2

 

8.14.6  PARTITION FORCE ARMING........................................................................................... 2

 

8.14.7  PARTITION HOLIDAY ARMING ....................................................................................... 2

 

Содержание SmartBus P900-TI6N

Страница 1: ...E ARMING 2 8 4 8 REMOTE CONTROL ARMING OPTIONAL 2 8 5 DISARMING THE SYSTEM 2 8 5 1 KEYPAD DISARMING 2 8 5 2 AUTO TIMER DISARMING 2 8 5 3 TELEPHONE REMOTE DISARMING 2 8 5 4 REMOTE CONTROL DISARMING OPTIONAL 2 8 6 TURN ON OFF HOME AUTOMATION POINT 2 8 7 BYPASS ZONE 2 8 8 UN BYPASS ZONE 2 8 9 VIEW SYSTEM TROUBLE 2 8 10 VIEW ALARM MEMORY 2 8 11 CHIME MODE 2 8 12 EMERGENCY SITUATION 2 8 13 PARTITIONING...

Страница 2: ... AUTOMATION 2 8 17 13 PROGRAM AUTO OFF TIMER 1 2 3 4 FOR HOME AUTOMATION 2 8 17 14 TO ERASE AUTO OFF TIMER 1 2 3 4 FOR HOME AUTOMATION 2 8 17 15 PROGRAM PERSONAL TELEPHONE NUMBER 1 2 3 4 2 8 17 16 TO ERASE PERSONAL TELEPHONE NUMBER 1 2 3 4 2 8 18 TESTING THE SYSTEM 2 8 18 1 WALK TEST 2 8 18 2 CMS TEST Manual Test 2 8 18 3 SIREN TEST 2 8 18 4 STROBE LIGHT TEST 2 8 18 5 BATTERY TEST 2 9 0 LCD KEYPAD...

Страница 3: ...ER USER CODE 2 9 19 4 PROGRAM NEW AND CHANGING EXISTING DURESS CODE 2 9 19 5 ERASE USER or DURESS CODE 2 9 19 6 PROGRAM SYSTEM TIMER 2 9 19 7 PROGRAM PARTITION 1 OR PARTITION 2 AUTO ARM TIMER 2 9 19 8 TO ERASE PARTITION 1 OR PARTITION 2 AUTO ARM TIMER 2 9 19 9 PROGRAM PARTITION 1 OR PARTITION 2 AUTO DISARM TIMER 2 9 19 10 TO ERASE PARTITION 1 OR PARTITION 2 AUTO DISARM TIMER 2 9 19 11 PROGRAM AUTO...

Страница 4: ...4 V1 1 SmartBus P900 TI6N USER MANUAL 9 20 5 BATTERY TEST 2 9 21 SYSTEM INFORMATION 2 9 22 SYSTEM SETTING 2 ...

Страница 5: ...ces will not operate without power Devices powered by AC will not work if there is no AC power supply for any reason and the back up battery is missing dead or improperly installed Alarm warning devices such as sirens may not alert people or wake up sleepers if they are located on the other side of closed or partly closed doors Telephone line needed to transmit alarm events from the premise to a c...

Страница 6: ...OWER zone will behave as an instant zone if it is violated prior to the violation of an ENTRY EXIT zone Force Arm Arming with exit delay that allows for certain violated zones to be bypassed temporary When the violated zones resume these zones will be protected There is an ENTRY delay time in this arming mode Home Automation HA Optional system expander module that allows you to control different l...

Страница 7: ...onds View Alarm Memory Hold down 8 for 2 seconds Program Chime Zone Hold down 9 for 2 seconds zone numbers 1 to 16 Holiday Mode Arming Hold down 0 for 2 seconds Activate Fire Alarm Hold down F for 2 seconds Activate Panic Alarm LED Hold down P for 2 seconds LCD Press MODE 8 Activate Medical Alarm LED Hold down M for 2 seconds LCD Press MODE 9 Turn On Off Keypad Buzzer and Speaker MODE 6 Toggle Chi...

Страница 8: ...n 1 or Partition 2 Day Arm Hold down 2 for 2 seconds Partition 1 or Partition 2 Night Arm Hold down 3 for 2 seconds Partition 1 or Partition 2 Force Arm Hold down 4 for 2 seconds Partition 1 or Partition 2 Holiday Mode Arming Hold down 0 for 2 seconds Partition 1 or Partition 2 TESTING THE SYSTEM Sensor Walk Test MODE 1 CMS Reporting Test MODE 2 Siren Test MODE 3 Strobe Light Test MODE 4 Battery T...

Страница 9: ...phone Reporting Immediately 2 Force Arm Disarm system 1 System Voice Report on Alarm triggered zone System Arm Disarm Zone Open Alarm Bypassed Siren On Off Fail AC power status Home Automation On Off 4 ON OFF Home Automation Point 01 to 16 HA Point number 00 ON OFF All HA Points Dial Phone Number Wait for Answer System Call Out System welcome note and voice menu 3 ON OFF Siren 01 to 16 Zone number...

Страница 10: ...10 V1 1 SmartBus P900 TI6N USER MANUAL PAGE 11 PAGE 44 7 0 LED AND LCD KEYPAD MODEL ...

Страница 11: ...11 V1 1 SmartBus P900 TI6N USER MANUAL L E D LED KEYPAD 8 0 LED KEYPAD ...

Страница 12: ...he alarm is triggered 1 AWAY ARM This key will activate the AWAY ARM mode when hold down for 2 seconds 2 DAY ARM This key will activate the DAY ARM mode when hold down for 2 seconds 4 FORCE ARM This key will activate the FORCE ARM mode when hold down for 2 seconds 3 NIGHT ARM This key will activate the NIGHT ARM mode when hold down for 2 seconds FIRE ALARM This key will activate the FIRE ALARM whe...

Страница 13: ...16 New Code Re enter New Code SYSTEM TIME CLOCK Press 17 Timer in 24 hour format PROGRAM SYSTEM CLOCK SECURITY AUTO ARM DISARM TIMERS Press 18 21 Timer in 24 hour format PROGRAM SECURITY TIMERS HOME AUTOMATION ON OFF TIMERS Press 22 29 Timer in 24 hour format PROGRAM HOME AUTOMATION TIMERS REPORTING TELEPHONE NUMBER Press 30 37 Reporting telephone number PROGRAM REPORTING TELEPHONE NUMBER EXIT USE...

Страница 14: ...ser Code User Code 6 06 New User Code Re enter New User Code User Code 7 07 New User Code Re enter New User Code User Code 8 08 New User Code Re enter New User Code User Code 9 09 New User Code Re enter New User Code User Code 10 10 New User Code Re enter New User Code User Code 11 11 New User Code Re enter New User Code User Code 12 12 New User Code Re enter New User Code User Code 13 13 New User...

Страница 15: ...ome Automation Auto OFF Timer 3 27 Home Automation Auto OFF Timer 3 Home Automation Auto ON Timer 4 28 Home Automation Auto ON Timer 4 Home Automation Auto OFF Timer 4 29 Home Automation Auto OFF Timer 4 Remark All programmed timer must be in 24 hour format e g 7 am 07 00 8 pm 20 00 Program Reporting Telephone Number Program Fixed Line Personal Telephone Number 1 30 Fixed line Personal Telephone N...

Страница 16: ...M Personal Telephone Number 3 36 GSM Personal Telephone Number 3 Program GSM Personal Telephone Number 4 37 GSM Personal Telephone Number 4 Remark Button P on the keypad is representing a PAUSE key of 5 seconds duration Button M on the keypad is representing a key of telephone system Program System Date System Date 38 Date DDMMYY ...

Страница 17: ...ou enter any mistakes press key and re enter the code followed by key to confirm you command 4 P1 indicator will illuminate 5 The keypad audible indicator will sound on and off for the duration of the EXIT delay 6 Any bypassed zones will be shown by the flashing zone indicators 7 Leave the premises only via the EXIT ENTRY zone 8 During AWAY arming the telephone line will be supervised hourly If th...

Страница 18: ...y bypassed shown by flashing zone indicators 9 User will be given an ENTRY delay time to DISARM the system when enter the protected premises via ENTRY EXIT zone 3 Press and hold down for 2 seconds 1 This arming mode is ideal for NIGHT time arming with user still remains in the protected premises 2 In this mode the system will be armed instantly with certain preprogrammed NIGHT STAY zones bypassed ...

Страница 19: ... 0 Press and hold down for 2 seconds 1 This arming mode is ideal for long away occasion holiday 2 In this mode the system will be AWAY armed Home Automation points will be random ON OFF every hour to simulate occupancy from 7pm to 1am 3 Ensure that all zone indicators are distinguished if not check that all protected premises are closed 4 Press and hold down key 0 for 2 seconds 5 P1 indicator will...

Страница 20: ... 3 The system will be armed with EXIT delay time which allows certain violated zones to be bypassed temporary When the violated zones resume the zone will be protected again 4 Press the remote control button or twist and release the key switch 5 The system will be armed instantly Leave the premises via ENTRY EXIT zone 6 P1 indicator will illuminate 7 The keypad audible indicator will sound 2 beeps...

Страница 21: ...er the user code 6 Once the system is disarmed the P1 indicator will extinguish and the keypad audible indicator will stop 7 If the MEMORY indicator is flashing upon entry there has been an intrusion Call for assistance The intruder may still be inside 8 If no valid user code has been entered by the end of the ENTRY delay period an ALARM condition will be registered and stored into the system MEMO...

Страница 22: ...INT NUMBERS Press and hold down for 2 seconds 1 to 16 1 Press and hold down key 5 for 2 seconds 2 The POWER and P1 indicators will slow flash and keypad audible indicator will sound 2 beeps Zone 1 to 16 will turn ON if the respective HA points are ON Zone 1 to 16 will turn OFF if the respective HA points are OFF 3 Enter the HA point numbers followed by key Keypad audible indicator will sound 2 bee...

Страница 23: ... mode and keypad audible indicator will sound 2 beeps to confirm the command 7 To bypass all zones at once press key 0 followed by 8 Keypad audible indicator will sound 2 beeps to confirm the command and the system will be back to normal mode 9 The relevant ZONE indicator will slow flash to indicate that the zone is bypassed now 10 Zones cannot be bypassed once the system is armed 11 All bypassed ...

Страница 24: ...sound 2 beeps to confirm the command and the system will be back to normal mode 9 The relevant ZONE indicator will extinguish to indicate that the zone is now active 7 Press and hold down for 2 seconds 1 The system will monitor a number of possible trouble conditions If one of these conditions occurs the following events will occur 2 The SERVICE indicator turns ON The SERVICE indicator will illumi...

Страница 25: ...MEMORY indicator slow flash The MEMORY indicator will extinguish once the user enters VIEW ALARM MEMORY mode 3 Press and hold down key 8 for 2 seconds The MEMORY indicator will turn ON and keypad audible indicator will sound 2 beeps 4 One or more ZONE indicators will turn ON to indicate the zones that cause the most recent alarm 5 Press key to exit and keypad audible indicator will sound 2 beeps T...

Страница 26: ...l activate the FIRE ALARM condition when it is held down for 2 seconds 2 The FIRE ALARM condition can also be triggered by an installed smoke detector which is set as fire zone 3 The siren will sound and the FIRE REPORTING CODE will be transmitted to the central monitoring station 4 To silence the siren enter a 4 digit user code followed by key PANIC MODE P Press and hold down for 2 seconds 1 The ...

Страница 27: ... down for 2 seconds 1 The MEDICAL ALARM condition will be activated when 2 Press and hold down M key for 2 seconds 3 The keypad audible indicator will sound to indicate that a MEDICAL ALARM has been initiated 4 The siren will sound and the MEDICAL REPORTING CODE will be transmitted to the central monitoring station 5 To silence the siren enter a 4 digit user code followed by key DURESS CODE 1 This...

Страница 28: ...ion 2 are armed However this sharing zone will be disarmed if either Partition 1 or Partition 2 is disarmed The installer must program the required user code settings These settings determine which user codes can arm Partition 1 as well as which user codes can arm Partition 2 Codes can also be given access to both partitions If your user code has access to both partitions USER CODE 1 2 Leave via E...

Страница 29: ...key 1 for 2 seconds 1 1 or 2 Press and hold down for 2 seconds 13 Zone indicator 1 and 2 will flash 14 Press key 1 followed by key 2 to arm both partitions If your user code has access to 2 partitions and you would like to arm Partition 1 only USER CODE 1 Leave via ENTRY EXIT Zone If your user code has access to 2 partitions and you would like to arm Partition 2 only USER CODE 2 Leave via ENTRY EX...

Страница 30: ...ss to 1 partition only USER CODE Leave via ENTRY EXIT Zone 1 Ensure that all zone indicators are distinguished if not check that all protected premises are closed 2 Press the key to cancel any unintended entries 3 Enter a valid 4 digit USER CODE If you enter mistakes press key and re enter the code followed by key to confirm your command 4 The P1 indicator will illuminate if the entered user code ...

Страница 31: ...cator will sound on and off for the duration of the EXIT delay Any bypassed zones will be shown by the flashing zone indicators 8 Leave the premises only via the EXIT ENTRY zone 9 During AWAY arming the telephone line will be supervised hourly If the telephone line is disconnected a new trouble condition will be registered please refer to View System Trouble at page 24 10 User will be given an ENT...

Страница 32: ...er will be given an ENTRY delay time to disarm the system when enter the protected premises via ENTRY EXIT zone 3 1 or 2 Press and hold down for 2 seconds 1 This arming mode is ideal for NIGHT time arming with user still remains in the protected premises 2 In this mode system will be armed instantly with certain preprogrammed NIGHT STAY zones bypassed automatically 3 Ensure that all zone indicator...

Страница 33: ...ones resume the zone will be protected again 2 Press and hold down key 4 for 2 seconds 3 Zone indicator 1 and 2 will flash 4 Press key 1 to arm Partition 1 or press key 2 to arm Partition 2 followed by key 5 The P1 indicator will illuminate if Partition 1 is armed 6 The P2 indicator will illuminate if Partition 2 is armed 7 Keypad audible indicator will sound on and off for the duration of the EXI...

Страница 34: ...ration of the EXIT delay Any bypassed zones will be shown by the flashing zone indicators 10 Leave the premises only via the EXIT ENTRY zone 11 User will be given an ENTRY delay time to disarm the system when enter the protected premises via ENTRY EXIT zone 12 After disarming Home Automation random ON OFF function will be deactivated and the system will resume to normal Home Automation ON OFF time...

Страница 35: ...mber of incorrect user codes which are entered consecutively more than the keypad lock counter Please refer to Installer Programming Section Keypad Lock Counter 13 If the ENTRY delay is too short have your installer to change the ENTRY delay period 14 If the MEMORY indicator is flashing upon entry there has been an intrusion Call for assistance The intruder may still be inside Master code is a 4 d...

Страница 36: ... to the setting that you wish to change Please refer to User Programming Summary Table at page 14 15 8 To exit user programming mode press MODE followed by key 1 Press MODE followed by key to exit 2 POWER and SERVICE indicators will stop flashing The keypad will sound 2 beeps to confirm the exit command 1 Ensure that the system is in USER PROGRAMMING mode page 36 Section 8 17 1 2 Enter COMMAND ADD...

Страница 37: ... followed by key 5 If the duress code is not used please ensure the code is erased 1 Ensure that the system is in USER PROGRAMMING mode page 36 Section 8 17 1 2 Enter COMMAND ADDRESS that you wish to erase followed by key 3 Enter 4 digit 0000 and re enter the 4 digit 0000 followed by key 4 Repeat step 2 3 to erase other user codes 5 To exit user programming mode press MODE followed by key 6 If any...

Страница 38: ... 24 hour format e g 8 00pm is 20 00 4 Press key to confirm the time 5 To exit user programming mode press MODE followed by key Enter 18 for Partition 1 Auto Arm Timer Enter 20 for Partition 2 Auto Arm Timer 1 Ensure that the system is in USER PROGRAMMING mode page 36 Section 8 17 1 2 Enter 18 or 20 for auto arm timer setting 3 Press key to erase previous AUTO ARM TIMER setting 4 To exit user progr...

Страница 39: ...revious AUTO DISARM TIMER setting 4 To exit user programming mode press MODE followed by key Enter 19 for Partition 1 Auto Disarm Timer Enter 21 for Partition 2 Auto Disarm Timer 1 Ensure that the system is in USER PROGRAMMING mode page 36 Section 8 17 1 2 Enter 22 or 24 or 26 or 28 for auto on timer setting 3 Enter the AUTO ON TIMER in 24 hour format e g 8 00pm is 20 00 4 Press key to confirm the...

Страница 40: ...rmat e g 8 00pm is 20 00 4 Press key to confirm the time 5 To exit user programming mode press MODE followed by key Enter 23 for auto off timer 1 Enter 25 for auto off timer 2 Enter 27 for auto off timer 3 Enter 29 for auto off timer 4 1 Ensure that the system is in USER PROGRAMMING mode page 36 Section 8 17 1 2 Enter 23 or 25 or 27 or 29 for auto off timer setting 3 Press key to erase previous AU...

Страница 41: ...ber System will only call through USER TELEPHONE NUMBER 2 if it fails to report through USER TELEPHONE NUMBER 1 during intrusion If the system fails to report through both of the telephone numbers a new trouble condition will be registered please refer to View System Trouble at page 24 Enter 30 for personal telephone number 1 Enter 31 for personal telephone number 2 Enter 32 for personal telephone...

Страница 42: ...f CMS Reporting 2 Press MODE 2 3 A CMS testing code will be sent to the central monitoring station 4 Wait for 2 minutes if CMS reporting fails then a new trouble condition will be registered 5 Press and hold down key 7 for 2 seconds to view trouble condition and consult your system installer 6 Please refer to View System Trouble at page 24 Section 8 9 1 Siren Test allows on site testing of siren f...

Страница 43: ...site testing of battery functionality 2 Press MODE 5 3 Wait for 5 seconds if back up battery fails then a new trouble condition will be registered 4 Press and hold down key 7 for 2 seconds to view the trouble condition and consult your system installer 8 18 5 BATTERY TEST ...

Страница 44: ...44 V1 1 SmartBus P900 TI6N USER MANUAL L C D LCD KEYPAD 9 0 LCD KEYPAD ...

Страница 45: ...IME mode when hold down for 2 seconds HASH ENTER This key will confirm all commands entered to the system KEYLOCK INDICATOR The icon is displayed when the keypad is locked MEMORY INDICATOR The indicator will be blinking when the alarm is triggered 1 AWAY ARM This key will activate the AWAY ARM mode when hold down for 2 seconds 2 DAY ARM This key will activate the DAY ARM mode when hold down for 2 ...

Страница 46: ...er 1 OFF HA Timer 1 ON HA Timer 2 OFF HA Timer 2 ON HA Timer 3 OFF HA Timer 3 ON HA Timer 4 OFF HA Timer 4 EXIT User Tel No 1 User Tel No 2 User Tel No 3 User Tel No 4 EXIT Passwords Timers EXIT Enter Code User Mode Installer Mode Walk Test CMS Test Siren Test Strobe Test Battery Test EXIT EXIT Software Info PROGRAM SYSTEM DATE Date GSM Tel No 1 GSM Tel No 2 GSM Tel No 3 GSM Tel No 4 EXIT Date GSM...

Страница 47: ...ey in New User Code Re confirm New User Code User Code 09 Key in New User Code Re confirm New User Code User Code 10 Key in New User Code Re confirm New User Code User Code 11 Key in New User Code Re confirm New User Code User Code 12 Key in New User Code Re confirm New User Code User Code 13 Key in New User Code Re confirm New User Code User Code 14 Key in New User Code Re confirm New User Code U...

Страница 48: ... time 0000 to 2359 F to erase the previous setting OFF HA Timer 4 Key in time 0000 to 2359 F to erase the previous setting Remark All programmed timer must be in 24 hour format e g 7 am 07 00 8 pm 20 00 Program Reporting Telephone Numbers Tel No s User Tel No 1 Key in 16 digit Tel No F to erase the previous setting User Tel No 2 Key in 16 digit Tel No F to erase the previous setting User Tel No 3 ...

Страница 49: ...the code followed by key to confirm you command 4 will be displayed 5 An EXIT delay countdown timer will be shown at the top right temporarily replace the clock and the keypad audible indicator will sound on and off for the duration of the EXIT delay 6 Any bypassed zones will be shown by the flashing zone underline 7 Leave the premises only via the EXIT ENTRY zone 8 During AWAY arming the telephon...

Страница 50: ...8 Any DAY STAY zones will be automatically bypassed which shown by flashing zone underline 9 User will be given an ENTRY delay time to DISARM the system when enter the protected premises via ENTRY EXIT zone 3 Press and hold down for 2 seconds 1 This arming mode is ideal for NIGHT time arming with user still remains in the protected premises 2 In this mode the system will be armed instantly with ce...

Страница 51: ...ill be shown at the top right temporarily replace the clock and the keypad audible indicator will sound on and off for the duration of the EXIT delay 5 Any bypassed zones will be shown by the flashing zone underline 6 User will be given an ENTRY delay time to DISARM the system when enter the protected premises via ENTRY EXIT zone 0 Press and hold down for 2 seconds 1 This arming mode is ideal for ...

Страница 52: ...ssed temporary When the violated zones resume the zone will be protected again 4 Press the remote control button or twist and release the key switch 5 The system will be armed instantly Leave the premises via ENTRY EXIT zone 6 icon will be displayed 7 An EXIT delay countdown timer will be shown at the top right temporarily replace the clock and the keypad audible indicator will sound 2 beeps to co...

Страница 53: ... Section 9 17 USER CODE 1 To disarm the system enter a valid 4 digit USER CODE followed by key before expiry of the entry delay time 2 Enter the premises through a designated ENTRY EXIT zone entering via other zones will trigger an alarm instantly 3 The ENTRY delay begins once the ENTRY zone is violated 4 The keypad audible indicator will sound for the duration of the ENTRY delay to indicate that ...

Страница 54: ...control button or twist and release the key switch 2 The icon will extinguish and the keypad audible indicator will sound 2 beeps to confirm the disarming 3 If programmed to do so the siren will sound briefly for this remote control disarming Please refer to Installer Programming Section System Option Setting 1 Your system can be programmed to automatically DISARM itself according to a programmed ...

Страница 55: ...ress key 0 followed by 5 Keypad audible indicator will sound 2 beeps to confirm the command and the system will be back to normal mode 6 ZONE NUMBERS Press and hold down for 2 seconds 1 to 16 1 Hold down key 6 for 2 seconds 2 The screen will show Bypass Info and keypad audible indicator will sound 2 beeps 3 Press the zone number that needs to be bypassed e g press 2 if you wish to bypass zone 2 4 ...

Страница 56: ...key 6 for 2 seconds 2 The screen will show the Bypass Zones and keypad audible indicator will sound 2 beeps 3 Press the zone number corresponding to the current bypassed zone e g press 2 if you wish to un bypass zone 2 4 To enter zone number more than 9 press button F to represent the ten s digit E g To enter zone number 12 press F 2 zone number 16 press F 6 5 Repeat step 3 or 4 to un bypass other...

Страница 57: ... and keypad audible indicator will sound 2 beeps 6 Possible trouble conditions AC Loss Real Time Clock Loss Program System Timer refer to page 74 Section 9 19 7 Siren Fail Battery Low Voltage Telephone Line GSM CMS Reporting Fail Telephone Line GSM Personal Reporting Fail Telephone Line Connection Fail Remark Telephone Line GSM CMS Reporting Fail Telephone Line GSM Personal Reporting Fail and Tele...

Страница 58: ... is someone enters or exits the front door the keypad will beep once when the door is opened provided the zone is a chime zone 9 ZONE NUMBERS Press and hold down for 2 seconds 1 to 16 1 Hold down key 9 for 2 seconds 2 The screen will show Chime Info and keypad audible indicator will sound 2 beeps 3 Press the key corresponding to the zone that you wish to be the chime zone 4 To enter zone number mo...

Страница 59: ...you wish to change the vocabulary setting 5 Press to exit 1 Press key to the HA Point Info menu when system in normal mode 2 Press to access into zone info setting Vocabulary settings are shown in the LCD 3 Continue press or to scroll up down for other zone vocabulary 4 Consult your system installer if you wish to change the vocabulary setting 5 Press to exit MODE MODE 1 The system will store up t...

Страница 60: ...ter a 4 digit user code followed by key PANIC MODE MODE 8 1 The PANIC ALARM condition will be activated when press MODE 8 2 The PANIC ALARM condition can also be activated by any FIXED or REMOTE PANIC button that has been installed 3 If the panic button is set as silent zone then the PANIC REPORTING CODE will be transmitted to the central monitoring station without the siren sounding Ensure that y...

Страница 61: ...lence the siren enter a 4 digit user code followed by key DURESS CODE 1 This is a special 4 digit user code that is only used in the unique situation where an intruder forces one to disarm the system under duress 2 When the duress code is entered the control panel will be disarmed However a DURESS REPORTING CODE is transmitted to the central monitoring station to inform them that you have been for...

Страница 62: ...ition 2 are armed However this sharing zone will be disarmed if either Partition 1 or Partition 2 is disarmed The installer must program the required user code settings These settings determine which user codes can arm Partition 1 as well as which user codes can arm Partition 2 Codes can also be given access to both partitions If your user code has access to both partitions USER CODE 1 2 Leave via...

Страница 63: ...sible to AWAY arm by simply press and hold down key 1 for 2 seconds 1 1 2 Press and hold down for 2 seconds 12 P1 and P2 options will be displayed 13 Press key 1 followed by key 2 to arm both partitions If your user code has access to 2 partitions and you would like to arm Partition 1 only USER CODE 1 Leave via ENTRY EXIT Zone If your user code has access to 2 partitions and you would like to arm ...

Страница 64: ...nected a new trouble condition will be registered please refer to View System Trouble at page 57 12 User will be given an ENTRY delay time to disarm the system when enter the protected premises via ENTRY EXIT zone If your user code has access to 1 partition only 1 Ensure that all zone indicators are distinguished if not check that all protected premises are closed 2 Press key to cancel any uninten...

Страница 65: ...ew trouble condition will be registered please refer to View System Trouble at page 57 12 User will be given an ENTRY delay time to disarm the system when enter the protected premises via ENTRY EXIT zone 1 1 or 2 Press and hold down for 2 seconds 1 Ensure that all zone indicators are distinguished if not check that all protected premises are closed 2 Hold down key 1 for 2 seconds 3 P1 and P2 optio...

Страница 66: ...the protected premises via ENTRY EXIT zone 2 1 or 2 Press and hold down for 2 seconds 1 This arming mode is ideal for DAY time arming with user still remains in the protected premises 2 In this mode system will be armed instantly with certain preprogrammed DAY STAY zones bypassed automatically 3 Ensure that all zone indicators are distinguished if not check that all protected premises are closed 4...

Страница 67: ... Press and hold down key 3 for 2 seconds 6 P1 and P2 options will be displayed 7 Press key 1 to arm Partition 1 or press key 2 to arm Partition 2 followed by key 8 The icon will be displayed if Partition 1 is armed 9 The icon will be displayed if Partition 2 is armed 10 Any NIGHT STAY zones will be automatically bypassed shown by flashing zone underline 11 There is no ENTRY delay in this arming mo...

Страница 68: ...n by the flashing zone underline 9 User will be given an ENTRY delay time to disarm the system when enter the protected premises via ENTRY EXIT zone 0 1 or 2 Press and hold down for 2 seconds 1 This arming mode is ideal for long away occasion holiday 2 In this mode the system will be AWAY armed Home Automation points will be random ON OFF every hour to simulate occupancy from 7pm to 1am 3 Ensure t...

Страница 69: ...ed and the system will resume to normal Home Automation ON OFF timers setting USER CODE 1 Enter the premises through a designated ENTRY EXIT zone entering via other zones will trigger an alarm instantly 2 The ENTRY delay begins once the ENTRY zone is violated 3 The keypad audible indicator will sound for the duration of the ENTRY delay to indicate that a valid user code is required 4 An ENTRY dela...

Страница 70: ...ease refer to Installer Programming Section Keypad Lock Counter 14 If the ENTRY delay is too short have your installer to change the ENTRY delay period 15 If the MEMORY indicator is flashing upon entry there has been an intrusion Call for assistance The intruder may still be inside Master code is a 4 digit personal identification number that allows you to enter certain programming mode arm or disa...

Страница 71: ...red Below the User Mode the Passwords command is ready to be entered 7 Use the key and key to scroll up and down Enter the command that you wish to change Please refer to User Programming Summary Table at page 47 48 8 To exit user programming mode press or exit from MENU 1 Press 2 Screen will show Menu at the bottom exactly like before entering the user programming mode and keypad will sound 2 bee...

Страница 72: ...exit user programming mode 8 If any of the user codes are not used please ensure that they are all erased 1 Ensure that the system is in USER PROGRAMMING mode page 71 Section 9 19 1 2 Press to access Passwords menu 3 Press to scroll down to Duress Code 4 Press to select Duress Code 5 Enter the new 4 digit DURESS CODE followed by key Example 1313 and press 6 Re enter the new 4 digit DURESS CODE fol...

Страница 73: ...words menu 3 Press to scroll down to select which user code that you wish to erase Example User Code 02 4 Press to select User Code 02 5 Enter 4 digit 0000 followed by key 6 Re enter the 4 digit 0000 followed by key 7 Repeat step 3 to 6 to erase other user codes 8 Press to exit user programming mode 9 If any of the user duress codes are not used please ensure that they are all erased Master code c...

Страница 74: ... 8 00pm is 20 00 5 Press key to confirm the time 6 Press to exit user programming mode 1 Ensure that the system is in USER PROGRAMMING mode page 71 Section 9 19 1 2 Press to scroll down to Timers 3 Press to access Timers menu 4 Press to access Arm P1 Timer for partition 1 auto arm timer or Press to scroll down to Arm P2 Timer and press for partition 2 auto arm timer 9 19 6 PROGRAM SYSTEM TIMER 9 1...

Страница 75: ...tion 9 19 1 2 Press to scroll down to Timers 3 Press to access Timers menu 4 Press to access Arm P1 Timer for partition 1 auto arm timer or Press to scroll down to Arm P2 Timer and press for partition 2 auto arm timer OR 5 Press the F key to disable auto disarm timer The setting will be set to 99 99 OR 6 Press key to erase previous AUTO DISARM TIMER setting 7 Press to exit user programming mode 9 ...

Страница 76: ...ress to select Disarm P1 Tmr Disarm P2 Tmr for auto disarm timer OR 6 Enter the AUTO DISARM TIMER in 24 hour format Example 8 00pm is 20 00 OR 7 Press key to confirm the time 8 Press to exit user programming mode 1 Ensure that the system is in USER PROGRAMMING mode page 71 Section 9 19 1 2 Press to scroll down to Timers 9 19 9 PROGRAM PARTITION 1 OR PARTITION 2 AUTO DISARM TIMER 9 19 10 TO ERASE P...

Страница 77: ... setting will be set to 99 99 OR 7 Press key to erase previous AUTO DISARM TIMER setting 8 Press to exit user programming mode 1 Ensure that the system is in USER PROGRAMMING mode page 71 Section 9 19 1 2 Press to scroll down to Timers 3 Press to access Timers menu 4 Press to scroll down to ON HA Tmr 1 and press for auto on timer 1 5 Enter the AUTO ON TIMER in 24 hour format Example 8 00pm is 20 0...

Страница 78: ... 71 Section 9 19 1 2 Press to scroll down to Timers 3 Press to access Timers menu 4 Press to scroll down to ON HA Tmr 1 and press for auto on timer 1 5 Press the F key to disable AUTO ON TIMER The setting will be set to 99 99 6 Press key to erase previous AUTO ON TIMER setting 7 Press to exit user programming mode Press to scroll down to ON HA Tmr 2 and press for auto on timer 2 Press to scroll do...

Страница 79: ...ress key to confirm the time 7 Press to exit user programming mode Press to scroll down to OFF HA Tmr 2 and press for auto off timer 2 Press to scroll down to OFF HA Tmr 3 and press for auto off timer 3 Press to scroll down to OFF HA Tmr 4 and press for auto off timer 4 1 Ensure that the system is in USER PROGRAMMING mode page 71 Section 9 19 1 2 Press to scroll down to Timers 3 Press to access Ti...

Страница 80: ...ess for auto off timer 2 Press to scroll down to OFF HA Tmr 3 and press for auto off timer 3 Press to scroll down to OFF HA Tmr 4 and press for auto off timer 4 1 Ensure that the system is in USER PROGRAMMING mode page 71 Section 9 19 1 2 Press to scroll down to Tel Nos 3 Press to access Tel No menu 4 Press to select User Tel No1 5 Enter the PERSONAL TELEPHONE NUMBER The maximum telephone number l...

Страница 81: ...e preprogrammed personal telephone number 1 system will contact PERSONAL TELEPHONE NUMBER 2 as a back up Press to scroll down to User Tel No2 and press Press to scroll down to User Tel No3 and press Press to scroll down to User Tel No4 and press 1 Ensure that the system is in USER PROGRAMMING mode page 71 Section 9 19 1 2 Press to scroll down to Tel Nos 3 Press to access Tel No menu 4 Press to sel...

Страница 82: ...lephone number length is 14 digits The entered number will be displayed on the screen 6 Press the F key to temporary erase setting or wrong keyed in numbers 7 Button on the keypad is representing a PAUSE key of 3 seconds duration 8 Button on the keypad is representing a key 9 Press key to confirm the setting 10 Press to exit user programming mode 11 If programmed so system will call out to user te...

Страница 83: ...Tel No menu 4 Press to select GSM Tel No 1 5 Press the F key to erase and the setting will be emptied 6 Press key to erase previous GSM telephone number setting 7 Press to exit user programming mode Press to scroll down to GSM Tel No2 and press Press to scroll down to GSM Tel No3 and press Press to scroll down to GSM Tel No4 and press 9 19 18 TO ERASE GSM TELEPHONE NUMBER 1 2 3 4 ...

Страница 84: ... must be tested at least once every 3 months If the system is not functioning accordingly please contact your system installer for technical assistance 1 Walk Test allows on site testing of each zone of the system 2 Press MODE 1 or from MENU i e Menu System Test WalkTest 3 Siren will trigger for 2 seconds and keypad buzzer will sound briefly if any zone is violated during walk test mode 4 If siren...

Страница 85: ...Menu System Test Siren Test 3 Siren will sound for 3 seconds 4 If siren does not sound consult your system installer 1 Strobe Light Test allows on site testing of strobe light functionality 2 Press MODE 4 or from MENU i e Menu System Test Strobe Test 3 Strobe light will flash for 15 seconds 4 If strobe light does not flash consult your system installer 1 Battery Test allows on site testing of batt...

Страница 86: ...6 7 8 9 10 11 12 13 14 15 16 CMS Central Monitoring Station Number _____________________ Central Monitoring Station Account Number _____________________ Servicing Installer company _____________________________ Contact person _____________________________ Contact number _____________________________ Installation Date ______ ______ ______ 9 21 SYSTEM INFORMATION ...

Страница 87: ...____ Telephone Number 4 _____________________________ Dialing Attempt _____________________________ times OPTIONAL GSM Telephone Reporting GSM Telephone Number 1 _____________________________ GSM Telephone Number 2 _____________________________ GSM Telephone Number 3 _____________________________ GSM Telephone Number 4 _____________________________ Home Automation Home Automation 1 Turn On Time __...

Отзывы: