23
V1.1
SmartBus P900-TI6N USER MANUAL
L
E
D
[6]
+ [ZONE NUMBERS] + [#]
(Press and hold down for 2 seconds) (1 to 16)
1. Press and hold down key
[6]
for 2 seconds.
2. The
P1
and
KEYLOCK
indicators will slow flash and keypad audible indicator will sound
2 beeps.
3. Press the zone number that needs to be bypassed, e.g. press
[2]
if you wish to bypass
zone 2.
4. To enter zone number more than 9, press button [F] to
represent the ten’s digit.
E.g. To enter zone number 12, press [F] + [2], zone number 16 press [F] + [6].
5. Repeat step 3 or 4 to bypass other zones.
6. Press
[#]
key to exit the bypass mode and keypad audible indicator will sound 2 beeps to
confirm the command.
7. To bypass all zones at once, press key
[0]
followed by
[#].
8. Keypad audible indicator will sound 2 beeps to confirm the command and the system will
be back to normal mode.
9. The relevant
ZONE
indicator will slow flash to indicate that the zone is bypassed now.
10. Zones cannot be bypassed once the system is armed.
11. All bypassed zones will be automatically un-bypassed each time the system is disarmed
and must be reapplied before the next arming.
[6]
+ [ZONE NUMBERS] + [#]
(Press and hold down for 2 seconds) (1 to 16)
1. Press and hold down key
[6]
for 2 seconds.
2. The
P1
and
KEYLOCK
indicators will slow flash and keypad audible indicator will sound
2 beeps.
8.7 BYPASS ZONE
8.8 UN-BYPASS ZONE