Page 6
4.0
Installation
4.1
Mounting Location
Choose an area located near chemical supply tank, chemical injection point, and electrical supply. Install pump
where it can be easily serviced.
!
316SS Mounting brackets are included. Mount pump to a secure surface using enclosed mounting hardware.
!
Mount pump close to injection point. Keep inlet (suction) and outlet (discharge) tubing as short as possible.
Longer discharge tubing increases back pressure at pump head.
!
A back flow prevention check valve is recommended at the discharge of the pump to prevent system fluid from
flowing back through the pump during tube replacement or if the tube should rupture.
!
A pressure relief valve is recommended at the discharge of the pump to prevent premature wear and damage to
the pump tube in the event the discharge line becomes blocked.
!
The Flex-Pro does not require back pressure. Pressure regulator valves are not required. Keep the discharge
pressure as low as possible to maximize tube life.
!
An anti-syphon valve is not required. Syphoning cannot occur.
4.2
Dimensions
All diagrams are strictly for guideline purposes only. Always consult an expert before
installing metering pump on specialized systems. Metering pump should be serviced by
qualified persons only.
n
Raise metering pump 4-1/2 inches (11.43 cm) off ground or a surface.
n
Made out of tough Stainless Steel.
n
Provides a stable mounting surface.
Stainless Steel extended brackets allow pump to be securely mounted to most any surface;
floor, shelf, or skid. Brackets lift pump up 4-1/2 inches (11.43 cm), for easy pump access in
hard to reach areas.
Model #
72000-380
Description
Extended Mounting Bracket, 1 Pair, SS, 4 SS Screws
OptionalExtended Brackets
Model Number 72000-380
!
Always wear protective clothing, face shield, safety glasses and gloves when working on
or near your metering pump. Additional precautions should be taken depending on
solution being pumped. Refer to MSDS precautions from your solution supplier.
Risk of chemical overdose. Be certain pump does not overdose chemical during
backwash and periods of no flow in circulation system.
CAUTION
!
CAUTION
!
CAUTION
A
B
C
D
E
10-3/4”
8-1/8”
15-1/4”
10”
12-1/4”
27.3
20.6
38.9
25.4
31.0
14-1/4”
12-1/8”
18-5/8”
11”
13-5/8”
36.1
30.8
47.3
27.9
34.6
F
4-1/4”
10.7
6”
15.2
14.2"
(36.1cm)
6.0"
(15.2cm)
12.13"
30.8cm)
Front View
11.0"
(27.9cm)
13.63”
(34.6cm)
18.63”
(47.3cm)
Right View
A
B
F
C
D
E
Mounting Hole Spacings
(for standard and extended type brackets)
A4 Series
11.50” (29.2 cm)
A3 Series
8.25” (20.9 cm)
2.5” (6.35 cm)
Flex-Pro
Maximum bolt hole size
0.200” diameter (4 places)