Page 12
Flex-Pro
9.0
Set FVS (Flow Verification System)
Used to monitor pump output. If pump does not dispense fluid when pump
head rotor is turning, pump will go into an alarm mode and stop pump. Blue-
White offers a flow verification sensor that can easily attach to fitting on pump.
Default settings:
000 (off)
Navigate to
Set FVS
menu by pressing
UP
and
DOWN
arrows at the same
time, then select Input Setup, then
Set FVS
.
Press UP or DOWN arrow to set the FVS delay time in seconds.
Press START to save changes and exit FVS screen.
Flow Verification System
(sensor sold separately)
Flex-Pro is equipped with a
Flow Verification System
which is designed to stop
pump and energize a 6 amp relay in event sensor does not detect chemical
during pump operation. This could indicate a clogged injection fitting, empty
chemical solution tank, worn pump tube, loose tubing connection, etc.
To allow pump to clear any gasses that may have accumulated during stopper
operation (such as with chlorine), an alarm delay time value from 1-255
seconds must be programmed (An alarm delay value of 000 seconds disables
FVS system).
If FVS alarm occurs, pump will stop, send an external signal (if setup), and
screen will flash FVS with an alarm icon.
To clear FVS alarm, you must press START button or re-cycle power (unplug
power to pump, then plug back in).
Install FVS Flow Sensor -
Flow Verification Sensor (FVS) should be installed
on the inlet (suction) side of the pump tube. Sensor includes a PVC tubing
insert, located inside sensors female thread connection, that is designed to
seal sensor onto pump tube inlet adapter. Thread sensor onto pump tube until
tubing insert is snug against pump tube inlet fitting - do not over-tighten.
- Set FVS
Input FVS Time Delay:
OFF = 000
Range = 001-255 seconds
00
0
Seconds
Manual Speed Adjust
OFF
Manual Speed Adjust
Press START to run
Confirm the FVS flow range -
Flow
Verification Sensor (FVS) will only function
within its operating range. See chart for
available ranges.
NOTE: For low viscosity (water-like) fluids
only. Consult the factory if attempting to
use with viscous fluids.
OPERATING
FLOW RANGE
(ml/min)
100-1000
FV-200-6V
200-2000
FV-300-6V
300-3000
FV-400-6V
500-5000
FV-500-6V
700-7000
FV-600-6V
SENSOR MODEL NUMBER
FVS
ALARM
When a FVS alarm occurs
STOP
30-300
FV-100-6V
FV-200-3V
FV-300-3V
FV-400-3V
FV-500-3V
FV-600-3V
FV-100-3V
3/8”OD tube
connections
1/2” F/NPT
connections