Page 17
Flex-Pro
Re-attach
Pump Head Cover
using the four
Thumb Screws
.
Pump will detect
Pump Head Cover
is installed and begin to exit MAINTENANCE
MODE.
Pump will ask you if Tube was replaced. Yes / No
If Yes is selected, pump ask you to reset Tube Timer. Yes / No
If Yes is selected, pump will display Current Tube Timer briefly (5 seconds) before
resetting to zero.
The pump can now begin normal operation.
MAINTENANCE MODE
Pump Cover Detected!
Press ENTER to set
Was Tube Replaced?
MAINTENANCE MODE
Up/Down to select
YES
NO
Insert suction fitting into pump head. Remove your fingers from
pump head. Start pump by pressing START button. Grab hold of
Tube Installation Tool and use it to leverage tubing into pump head.
Introduce tubing into pump head while the rotor is rotating. Avoid
using fingers to guide the tubing. Stop pump at anytime by
pressing STOP button. Start pump by pressing START button.
Continue to follow rotation of rotor while directing tube into pump
head. At this point, you may need to pull Tube Installation Tool to
stretch tubing into position. Let rotor spin a few rotations while
pulling Installation tool so fitting can be properly installed.
Continue to pull Tube Installation Tool to allow enough room to
slide discharge fitting into pump head tongue and groove. Once
discharge fitting is secured in pump head, stop pump by pressing
STOP button. Replace pump head cover. Pump will ask you if
you’d like to reset tube timer. If you choose yes, current tube time
will display for 5 seconds before resetting to zero. Make note of
your displayed tube life. Select Yes again to reset tube life timer.
1
2
3
PULL
4