3.0
Features
Enclosure Rating:
NEMA 4X:
Constructed for either indoor or outdoor use to provide a degree of protection to personnel against
incidental contact with enclosed equipment; to provide a degree of protection against falling dirt, rain, sleet, snow,
windblown dust, splashing water, and hose-directed water; and that will be undamaged by external formation of ice
on enclosure.
IP66:
No ingress of dust; complete protection against contact. Water projected in powerful jets against enclosure from
any direction shall have no harmful effects.
Page 5
!
Peristaltic pump design does not have valves that can clog requiring maintenance.
!
Self priming - even against maximum line pressure. By-pass valves are not required. Cannot vapor lock or
lose prime. Syphoning cannot occur.
!
Output rates to: 158.5 GPH (600 LPH) and pressures to 125 PSI (8.6 Bar).
!
No maintenance brushless variable speed motor.
!
Specially engineered tubing for long life at high pressures.
!
Patented Tube Failure Detection (TFD) system. Senses tube failure by detecting chemical in the pump head.
No false triggering.
!
2500:1 turndown ratio.
!
Remote start/stop.
!
Operator friendly digital touch pad.
!
VGA Graphic multi-color backlit LCD displays remote/local control status, motor speed, output rate, service
and alarm status.
!
Outputs include one 250V/6A Form C no/nc relay assigned to monitor both the TFD, FVS systems.
!
Two molded squeeze and alignment rollers for optimum squeeze, unparalleled accuracy, and tube life.
!
Heavy duty rotor - single piece plastic rotor means no flexing and increased accuracy (no metal springs or
hinges to corrode).
!
Inject at maximum PSI in either direction (clockwise and counter clockwise).
!
Compatible with Blue-White’s output Flow Verification Sensor (FVS) system.
3.1
Agency Listings
Symbol
Explanation
!
WARNING, risk of electric shock
CAUTION, refer to users’ guide
GROUND, PROTECTIVE CONDUCTOR TERMINAL
Flex-Pro
This pump is ETL listed to conforms to the following:
UL Standard 778 as a motor operated water pump
CSA Standard C22.2 as process control equipment
This pump complies to the Machinery Directive 98/37/EC, BS EN 60204-1, Low Voltage Directive
73/23/EC BS EN 61010-1, EMC Directive 89/336/EC, BS EN 50081-1/BS EN 50082-1.