Fornacher Strasse 12
Tel43 (720) 010 188
A-4870 Vöcklamarkt
Email:
Austria
www.bluesky-energy.eu
January 10, 2020/greenrock-heimspeicher_installations- & inbetriebnahmehandbuch_v02_en
9
WARNING
The GREENROCK energy storage can release traces of gases during operation:
H2, O2, CO2, CO. To stop these gases collecting, appropriate measures are required.
Measures
A natural ventilation of 0.5 m
3
/h per installed kWh is recommended.
If the natural ventilation of the installation site is not sufficient, appropriate technical ventilation must be
provided.
2.3
Thermal hazards
WARNING
Risk of injury due to hot Combiner Board! The Combiner Board inside the energy storage could become very hot, so
appropriate measures are necessary.
Measures
Do not touch Combiner Board.
WARNING
Fire hazard through covered openings and gaps! The GREENROCK energy storage can become very hot during
operation. The openings and gaps of the energy storage are deliberately designed!
Measures
The energy storage must not be used as a shelf!
The openings and gaps of the energy storage must not be covered!
2.4
Physical hazards
WARNING
Risk of injury and/or material damage due to heavy battery stacks. The battery stacks of the GREENROCK energy
storage weigh 140 kg. Appropriate measures are necessary to avoid injuries.
Measures
When transporting and setting up the energy storage, appropriate aids must be used to ensure safe working
(safety shoes/gloves/hand pallet truck/sack truck/crane).
WARNING
Risk of injury or death and/or damage to property due to overturning of the energy storage. The GREENROCK
energy storage is high and heavy. Appropriate measures are necessary to prevent the energy storage from tipping
over or falling over.
Measures
The energy storage must be fixed to a wall with material suitable for the masonry.