2.  On your second call within “3” minutes, let the phone ring 

     until the System answers. The System will answer 

     first because it remembered the first “3” rings, and then 

     answers with an audible system status.  If done properly, the 

     answering machine/voice mail will not answer.  

HOW TO CANCEL ALARM PHONE CALLS FROM YOUR 

SYSTEM

To cancel the alarm phone call from one of the numbers in the 

phone call list:
To cancel a call out sequence from the System while listening to 

an alarm message, do the following:
1.  Answer the phone call.
2.  Listen to the alarm message.
3.  When told, press the number “1” key followed by the 

     pound (#) key within “1” minute to cancel the alarm call 

     out. You can cancel the call at anytime during the 

     message.  
4.  You can listen until you hear the System say goodbye 

     or just hang up the phone.
5.  If you do not cancel the call, the system will call the next 

     number in your phone number list. The first cancel will 

     stop all calls for all numbers. This sequence will repeat 

     every 15 minutes until a call is cancelled.  
To cancel the alarm phone call using the System display:
Press and hold the RESET button once to cancel the call (phone 

icon is present) and the RESET up to 5 seconds if multiple 

errors/alarms are present on the display to stop receiving phone 

calls. You will then be required to also clear/reset the message(s) 

on the display.  
 

 

PLACE A PHONE CALL TO YOUR SYSTEM TO CANCEL AN 

ALARM

To cancel a call out sequence during an active alarm condition, 

do the following:
1.  Make the call to the System (phone number at alarm 

     location)
2.  Wait for the System to answer (5 or 10 rings Menu option 

     selectable)
3.  Listen to the alarm message.
4.  Press the number “1” key followed by the pound (#) key 

     anytime during the message to cancel the alarm call out 

     and then hang up the phone.

REMOTE STATUS CHECK 

The System will answer incoming calls if a warning condition 

exists on the display. When no alarm issue exists, you will get 

a general status update.  If the call out sequence has been 

cancelled for an alarm by pressing "1" then "#" on the phone, 

but the alarm condition still exists on the display, the System will 

answer and describe the alarm condition.

CANCELING AN ALARM CALL OUT SEQUENCE WITH AN 

ANSWERING MACHINE/VOICE MAIL DEVICE ON THE SAME 

PHONE LINE

To cancel the alarm call out-sequence, do the following:

STEP ACTION

1.  Make the call to the System (phone number at alarm 

     location).
2.  Let the phone ring the desired number of times (before the 

     other in-line answering machine/voice mail can answer), Hang 

     the phone up.
3.  Call the number a second time within three minutes (The 

     System keeps track of all the rings from the previous 

     calls, accumulates them until the total ring count matches its 

     ring count number, 5 or 10, and then it will answer). Listen to 

     the alarm message.
4.  Press the number “1” key followed by the pound (#) key 

     anytime during the message to cancel the alarm call out. Hang 

     up the phone.

Operation

1.  After installation, the back-up pump will start once the water 

     level raises the bottom float.  

2.  The System has a charging circuitry designed to optimize the 

     recharging time of your battery and to prevent overcharging. 

     In addition, the control box has a time delay which keeps the 

     pump from repeated, short cycles when it shuts off. This 

     time delay feature will allow the pump to run 15 seconds 

     after the switch reaches the off position.

3.  MUTE FUNCTION: Press the mute button once to silence the 

     alarm for 12, 24, or 48 hours (menu selectable). To turn off the 

     mute timer, press and hold the RESET button down for 5  

     seconds.

1.  Unplug the transformer.

2.  For batteries with top caps that can be removed, the 

     electrolyte level should be checked and filled to 

     manufacturer’s specifications. The charge for each cell 

     should be checked with a hydrometer. A specific gravity of 

     1.265 indicates the battery is at full charge. If the specific 

     gravity of any of the cells varies more than .050, the battery 

     should be replaced.
3.  If the battery fluid levels are low or battery plates are exposed, 

     refer to the manufacturer's recommendations on how to 

     replenish properly.
4.  Inspect the terminals and clamps for corrosion and 

     tightness. Clean and tighten as required.

EXTENSION CORDS

We DO NOT recommend using extension cords, but if you find it 

absolutely necessary then:
1.  Use at least a 16 gauge cord that does not exceed 50 feet 

     in length.

 

Explosion hazard. Smoking  

 

 

 

and open flames prohibited. 

Battery recharging and connections MUST be performed 

in a well ventilated area. Before servicing the batteries, 

blow away the gases by waving a piece of cardboard near 

the batteries. 

Battery Care and Maintenance

 

If the System is set to answer in 10 rings (one of 

 

the Menu selectable options), you will need to 

place more calls within "3" minutes to get the System to eventually answer.

 

Canceling the call out sequence does not 

 

cancel an active alarm. System will continue 

to beep and the alarm message will be displayed on the digital display 

until you hit reset for each message/condition. If you do not hit reset, each 

alarm message on the display system will recall the phone number(s) in 

the last 72 hours as a reminder for the uncleared alarm conditions. 

 

An inexpensive hydrometer can be purchased at 

 

an automotive parts dealer.

8

Operating Instructions and Parts Manual

 

www.blueangelpumps.com

Содержание DF12VSM

Страница 1: ...es not include 12 Volt DC deep cycle battery phone jack phone line pipe and necessary fittings Float Switch Security DC Pump Requires active telephone land line service STEP 2 DISCONNECT POWER If the...

Страница 2: ...Notes 2 Operating Instructions and Parts Manual www blueangelpumps com...

Страница 3: ...lure to follow these instructions WILL result in bodily injury or death Electric shock hazard Disconnect power before servicing Apply a fixed lock or tag to prevent unexpected application of power Ele...

Страница 4: ...low the pump or check valve to be removed easily for servicing 8 Check valve is recommended for effective operation of system The remainder of the discharge pipe installation will vary depending on in...

Страница 5: ...etal pipe is required for permanent installation 9 Glue a 45 elbow to the short pipe on the Back Up DC Pump Glue a Y adapter to the short pipe on the existing pump as shown in illustration for Method...

Страница 6: ...negative terminal of the battery The display should be lit up at this time If connected improperly an alarm will sound until corrected 4 Plug the pump and float switch connectors into the 12 Volt Adva...

Страница 7: ...umber hit ENTER then select the TEST option The system will immediately dial the desired phone number Upon answering the unit will play the following message This is a test of the back up system It wi...

Страница 8: ...cond time within three minutes The System keeps track of all the rings from the previous calls accumulates them until the total ring count matches its ring count number 5 or 10 and then it will answer...

Страница 9: ...determine the number of devices that may be connected to a telephone line Excessive REN s on a telephone line may result in the devices not ringing in response to an incoming call In most but not all...

Страница 10: ...ber at alarm location let ring three 3 times hang up 2 Make a second call to the System within 3 minutes the System will answer on the second ring 3 rings 2 rings System answers on fifth 5th ring 3 Li...

Страница 11: ...place if low or defective 5 Check to make sure the back up pump is not air locked Locate the vent hole inspect and clear the hole using a pipe cleaner Pump Cycles Too Frequently 1 Check valve problem...

Страница 12: ...allow limitations on how long an implied warranty lasts or do not allow the exclusions or limitations of incidental or consequential damages so the above lim i ta tions might not apply to you This li...

Страница 13: ...Interrupteur flotteur S curit Pompe c c Requiert un service de ligne terrestre t l phonique actif TAPE 2 METTRE HORS TENSION Si la source de courant n est pas visible verrouiller en position ouverte a...

Страница 14: ...Remarques 14 Fr Instructions d Utilisation et Manuel de Pi ces www blueangelpumps com...

Страница 15: ...que NE PAS marcher sur un sol mouill avant que le courant ne soit coup Faire appel un lectricien agr pour effectuer l entretien conform ment au Code national de l lectricit et aux codes locaux PROPOSI...

Страница 16: ...ser des pratiques de plomberie s res pour acheminer le tuyau de d charge vers un mur ext rieur par le chemin le plus court R duire le nombre de coudes au maximum dans la mesure o qu ils r duisent le d...

Страница 17: ...er un coude de 45 au tuyau court de la pompe de secours c c Coller un adaptateur en Y au tuyau court de la pompe existante comme indiqu sur l illustration de la m thode 2 10 Coller une section courte...

Страница 18: ...de la batterie puis connecter le fil noir sur la borne n gative de la batterie L affichage devrait alors s allumer En cas de branchement incorrect une alarme se d clenche jusqu ce que le probl me soit...

Страница 19: ...minuteries et toutes les erreurs sont effac es de la m moire du syst me maintenir le bouton RESET r initialisation enfonc pendant au moins 3 5 secondes 2 Appuyer sur le bouton MENU suivi de l option...

Страница 20: ...RIE VOCALE EST INSTALL SUR LA M ME LIGNE T L PHONIQUE Pour annuler la s quence d appel d alarme sortant suivre les tapes suivantes TAPES SUIVRE 1 Appeler le syst me le num ro de t l phone du site de l...

Страница 21: ...dant lorsqu un avis pr alable n est pas possible la compagnie de t l phone avisera le client d s que possible En outre vous serez inform de votre droit d poser une plainte aupr s de la FCC si vous le...

Страница 22: ...g e 60 Batterie charg e 40 Batterie charg e 20 Batterie d charg e tat de la batterie sujet caution APPELT L PHONIQUE ALARME SONORE SIGNALDU SYST ME DE S CURIT Inverser la polarit Figure 6 Tableau des...

Страница 23: ...terie faible ou d fectueuse 3 Interrupteur flotteur coinc 4 Fusible d fectueux ou grill 1 V rifier toutes les connexions 2 V rifier la batterie et la remplacer si elle est faible ou d fectueuse 3 S as...

Страница 24: ...site de l alarme laisser sonner trois 3 sonneries puis raccrocher 2 Appeler le syst me une seconde fois dans les 3 minutes qui suivent le syst me r pondra au bout e deux sonneries 3 2 sonneries le sys...

Страница 25: ...clusion ou la limitation des dommages accessoires ou indirects en cons quence les limitations pr c dentes peuvent ne pas s appliquer tous les cas Cette garantie limit e vous conf re des droits juridiq...

Страница 26: ...dor Seguridad Bomba CC Requiere un servicio de tel fono de l nea activado PASO 2 DESCONECTE LA ENERG A Si la protecci n de desconexi n no est a la vista tr nquela en la posici n abierta y etiqu tela p...

Страница 27: ...Notas 27 Sp DF12VSM www blueangelpumps com...

Страница 28: ...u cable de corriente PUEDEN contener qu micos incluido plomo que son conocidos por el Estado de California como causantes de c ncer y defectos de nacimiento u otros da os reproductivos L vese las mano...

Страница 29: ...n para un funcionamiento eficaz del sistema El resto de la instalaci n de la tuber a de descarga variar dependiendo de las circunstancias individuales Dirija la tuber a de descarga hacia una pared ex...

Страница 30: ...segunda bomba 9 Pegue un codo de 45 al tubo corto en la bomba de respaldo de CC Pegue un adaptador en Y al tubo corto en la bomba existente como se muestra en la ilustraci n del M todo 2 10 Pegue una...

Страница 31: ...tiva de la bater a La pantalla debe iluminarse en este momento Si se conecta de forma incorrecta sonar una alarma hasta que se corrija 4 Enchufe la bomba y los conectores del interruptor de flotador e...

Страница 32: ...l nea telef nica est conectada y que la Home Screen pantalla de inicio no tenga mensajes de error 2 Presione el bot n MENU men seguido de la opci n Phone Setup configuraci n del tel fono 3 Despl cese...

Страница 33: ...NTESTADORA AUTOM TICA CORREO DE VOZ EN LA MISMA L NEA TELEF NICA Para cancelar la secuencia de llamadas de alarma haga lo siguiente PASOS QUE DEBE REALIZAR 1 Realice la llamada al Sistema n mero de te...

Страница 34: ...E LA RED TELEF NICA Si este Sistema causa da o a la red telef nica la compa a telef nica le notificar con anticipaci n que puede ser necesaria la suspensi n temporal del servicio Pero si el aviso con...

Страница 35: ...lente El motor zumba pero la bomba no funciona 1 Bater a defectuosa 2 El impulsor est bloqueado 1 Verifique la bater a y reempl cela si el flujo es bajo o defectuoso 2 Desconecte la bomba retire la re...

Страница 36: ...cionamiento de menos de 1 hora 1 Corte de energ a 2 Corte de energ a extendido 1 Notifique a la compa a de servicios p blicos 2 Prepare una bater a de repuesto Cambie la bater a 1 La bater a tiene poc...

Страница 37: ...est configurado a 5 repiques 1 Haga una llamada al Sistema n mero de tel fono de la ubicaci n de la alarma deje sonar 3 tres veces cuelgue 2 Realice una segunda llamada al Sistema en 3 minutos el Sist...

Страница 38: ...as garant as impl citas o no permiten las exclusiones o limitaciones de da os incidentales o consecuentes de manera que las limitaciones mencionadas anteriormente pueden no aplicarse en su caso Esta g...

Страница 39: ...Notes Remarques Notas 39 Sp DF12VSM www blueangelpumps com...

Страница 40: ...Notes Remarques Notas 40 Sp Manuel de Instrucciones y Lista de Piezas www blueangelpumps com...

Отзывы: