 It is recommended that a person at the call-to 

location confirms receiving the test phone call. Validate all calls 

before concluding that the system setup is finished.

ENTERING AND CHANGING PHONE NUMBERS

When programming phone numbers into the System, enter each 

phone number into the phone setup screens exactly as you 

would when making a personal phone call.  
Two phone number entry methods:
1.  As part of the Installation Setup procedure (follow the on 

     screen prompts) or,
2.  From the “Home Screen”, select “MENU”, enter the security 

     code (if prompted), then locate the “Phone Setup” option 

     and then press the button for “ENTER”.  
 

a. You can modify, delete, or verify within this selection.   

 

b. To delete any number, simply press “DEL” and it will  

      

    backspace as needed. 

 

c. To EDIT a number, re-enter the phone number and it 

 

    will overwrite the existing number.

PROPER PHONE NUMBER ENTRY

System can place local calls, long distance calls, and even 

international calls. The use of calling cards is not recommended 

for they are difficult to enter and can change without notice and 

result in a phone call never being made. 
Example:
 

*Local Number:  123-4567

 

*Long Distance:  1 (555) 123-4567

 

* International: Country code, followed by 1, then the 

 

phone number. For proper dialing instructions or 

 

further assistance, contact your service provider. 

 

Enter the phone number exactly as you would when    

 

dialing a call yourself.  If your local number requires the  

 

area code, enter as needed.

CREATING PAUSES WHEN ENTERING PHONE NUMBERS:

Some phone calls require accessing an outside telephone line 

from a digital system. Obtain the digit(s) necessary to access 

the outside line (dialing “9” to access an outside line is most 

common). A time delay may be required to let the system fully 

access the outside line and this is accomplished by entering 

two “stars” (**) after dialing the 9. 
The following examples use a “9” to access the outside phone 

line followed by a 2 second delay before the auto-dialer is 

initiated to place an automated phone call by the System:  

 

 

Local call:  9** then 123-4567

          

Long distance call:  9** then 1 (555) 123-4567

TIME DELAYS

  

 

** = 2 seconds, **** = 4 seconds, ****** = 6 seconds

All stars (*) must be entered in multiples of 2 or the system will 

not recognize them as actual time delays.

PHONE TEST

After entering all phone numbers, it is crucial that you test your 

System to verify that it can reach the call list phone numbers.

 

TESTING YOUR 12 VOLT ADVANCED NOTIFICATION SYSTEM 

PHONE NUMBERS

To test the System, do the following:
1.  Make sure the System is powered up, phone line is 

     connected, and the "Home Screen" has no error messages. 

     To make sure all timers and errors are cleared from the 

     system memory, press and hold the "RESET" button for 

     a minimum of 3-5 seconds. 
2.  Press the MENU button followed by the “Phone Setup” 

     option.  
3.  Scroll to the desired phone number, hit ENTER, then select 

     the TEST option.
The system will immediately dial the desired phone number. 

Upon answering, the unit will play the following message: “This 

is a test of the back-up system.” It will repeat this message for 

approximately “1” minute and then hang up. The display will 

prompt you asking if the test was successful, if Yes, it returns to 

the home screen. If “NO”, it will retest. 
4.  Repeat Steps 2 and 3 to test the remaining phone numbers.
The System does not provide any indication of call success; 

therefore, you must verify that the call was made successfully.

TESTING FOR A SPECIFIC ALARM CONDITION

To test for a specific alarm condition you will have to simulate 

that specific alarm condition and then verify if the alarm phone 

calls went through. In those scenarios, you must cancel the 

alarm call out sequence and correct the alarm condition by 

pressing and holding the RESET button for a minimum of 5 

seconds.

HOW THE SYSTEM WORKS WITH VOICE MAIL OR AN 

ANSWERING MACHINE

When it is necessary to connect an answering machine or voice 

mail device to the same phone line as the System, you can still 

use all the features of these devices, along with being able to 

check status and cancel an alarm call out of the System.

HOW THIS WORKS:

The System can answer incoming calls to check the system 

status. To do this, the ring count must be set to answer on 

either “5” or “10” rings (default setting is 10 rings, change this 

setting from the Main Menu>Set Ring Count).
Set your answering machine or voice mail to answer in fewer 

rings than the System. (For example, if the System is set to 

answer on 5 rings, set the answering machine/voice mail to 

answer in “4” or fewer rings.) Therefore, when a call comes into 

the location of the System, the answering machine/voice mail 

will respond first because it is set to answer in fewer rings than 

the System.

RING COUNT TIMER

The ring count timer works in the following way: when the first 

call comes in during an alarm event, the internal system timer 

starts counting down for “3” continuous minutes. If the System 

receives enough rings to answer (within “3” minutes), it will 

respond, and the ring counter will reset to “0” regardless if the 

three minutes have elapsed or not. Also, the timer will reset 

to “0” if no additional calls are received during a three minute 

period (multiple calls to the System within “3”minutes will not 

reset the ring timer).

CALLING THE 12 VOLT ADVANCED NOTIFICATION SYSTEM 

DURING AN ALARM EVENT

Example: 
1) The back-up system is set to answer in 5 rings (ring count 

setting).  
2) The answering machine/voice mail is set to answer in "4" 

rings or fewer.
To get the System to respond given the above example criteria, 

do the following:
1.  Call the phone number of the location where the 

     System is located, and let the phone ring “3” times 

     and then hang up. The internal 3-minute timer starts and 

     the System tallies and remembers the number of rings.

 

The CANCEL key does not function when the 

 

System is in "test mode".

7

DF12VSM

www.blueangelpumps.com

Содержание DF12VSM

Страница 1: ...es not include 12 Volt DC deep cycle battery phone jack phone line pipe and necessary fittings Float Switch Security DC Pump Requires active telephone land line service STEP 2 DISCONNECT POWER If the...

Страница 2: ...Notes 2 Operating Instructions and Parts Manual www blueangelpumps com...

Страница 3: ...lure to follow these instructions WILL result in bodily injury or death Electric shock hazard Disconnect power before servicing Apply a fixed lock or tag to prevent unexpected application of power Ele...

Страница 4: ...low the pump or check valve to be removed easily for servicing 8 Check valve is recommended for effective operation of system The remainder of the discharge pipe installation will vary depending on in...

Страница 5: ...etal pipe is required for permanent installation 9 Glue a 45 elbow to the short pipe on the Back Up DC Pump Glue a Y adapter to the short pipe on the existing pump as shown in illustration for Method...

Страница 6: ...negative terminal of the battery The display should be lit up at this time If connected improperly an alarm will sound until corrected 4 Plug the pump and float switch connectors into the 12 Volt Adva...

Страница 7: ...umber hit ENTER then select the TEST option The system will immediately dial the desired phone number Upon answering the unit will play the following message This is a test of the back up system It wi...

Страница 8: ...cond time within three minutes The System keeps track of all the rings from the previous calls accumulates them until the total ring count matches its ring count number 5 or 10 and then it will answer...

Страница 9: ...determine the number of devices that may be connected to a telephone line Excessive REN s on a telephone line may result in the devices not ringing in response to an incoming call In most but not all...

Страница 10: ...ber at alarm location let ring three 3 times hang up 2 Make a second call to the System within 3 minutes the System will answer on the second ring 3 rings 2 rings System answers on fifth 5th ring 3 Li...

Страница 11: ...place if low or defective 5 Check to make sure the back up pump is not air locked Locate the vent hole inspect and clear the hole using a pipe cleaner Pump Cycles Too Frequently 1 Check valve problem...

Страница 12: ...allow limitations on how long an implied warranty lasts or do not allow the exclusions or limitations of incidental or consequential damages so the above lim i ta tions might not apply to you This li...

Страница 13: ...Interrupteur flotteur S curit Pompe c c Requiert un service de ligne terrestre t l phonique actif TAPE 2 METTRE HORS TENSION Si la source de courant n est pas visible verrouiller en position ouverte a...

Страница 14: ...Remarques 14 Fr Instructions d Utilisation et Manuel de Pi ces www blueangelpumps com...

Страница 15: ...que NE PAS marcher sur un sol mouill avant que le courant ne soit coup Faire appel un lectricien agr pour effectuer l entretien conform ment au Code national de l lectricit et aux codes locaux PROPOSI...

Страница 16: ...ser des pratiques de plomberie s res pour acheminer le tuyau de d charge vers un mur ext rieur par le chemin le plus court R duire le nombre de coudes au maximum dans la mesure o qu ils r duisent le d...

Страница 17: ...er un coude de 45 au tuyau court de la pompe de secours c c Coller un adaptateur en Y au tuyau court de la pompe existante comme indiqu sur l illustration de la m thode 2 10 Coller une section courte...

Страница 18: ...de la batterie puis connecter le fil noir sur la borne n gative de la batterie L affichage devrait alors s allumer En cas de branchement incorrect une alarme se d clenche jusqu ce que le probl me soit...

Страница 19: ...minuteries et toutes les erreurs sont effac es de la m moire du syst me maintenir le bouton RESET r initialisation enfonc pendant au moins 3 5 secondes 2 Appuyer sur le bouton MENU suivi de l option...

Страница 20: ...RIE VOCALE EST INSTALL SUR LA M ME LIGNE T L PHONIQUE Pour annuler la s quence d appel d alarme sortant suivre les tapes suivantes TAPES SUIVRE 1 Appeler le syst me le num ro de t l phone du site de l...

Страница 21: ...dant lorsqu un avis pr alable n est pas possible la compagnie de t l phone avisera le client d s que possible En outre vous serez inform de votre droit d poser une plainte aupr s de la FCC si vous le...

Страница 22: ...g e 60 Batterie charg e 40 Batterie charg e 20 Batterie d charg e tat de la batterie sujet caution APPELT L PHONIQUE ALARME SONORE SIGNALDU SYST ME DE S CURIT Inverser la polarit Figure 6 Tableau des...

Страница 23: ...terie faible ou d fectueuse 3 Interrupteur flotteur coinc 4 Fusible d fectueux ou grill 1 V rifier toutes les connexions 2 V rifier la batterie et la remplacer si elle est faible ou d fectueuse 3 S as...

Страница 24: ...site de l alarme laisser sonner trois 3 sonneries puis raccrocher 2 Appeler le syst me une seconde fois dans les 3 minutes qui suivent le syst me r pondra au bout e deux sonneries 3 2 sonneries le sys...

Страница 25: ...clusion ou la limitation des dommages accessoires ou indirects en cons quence les limitations pr c dentes peuvent ne pas s appliquer tous les cas Cette garantie limit e vous conf re des droits juridiq...

Страница 26: ...dor Seguridad Bomba CC Requiere un servicio de tel fono de l nea activado PASO 2 DESCONECTE LA ENERG A Si la protecci n de desconexi n no est a la vista tr nquela en la posici n abierta y etiqu tela p...

Страница 27: ...Notas 27 Sp DF12VSM www blueangelpumps com...

Страница 28: ...u cable de corriente PUEDEN contener qu micos incluido plomo que son conocidos por el Estado de California como causantes de c ncer y defectos de nacimiento u otros da os reproductivos L vese las mano...

Страница 29: ...n para un funcionamiento eficaz del sistema El resto de la instalaci n de la tuber a de descarga variar dependiendo de las circunstancias individuales Dirija la tuber a de descarga hacia una pared ex...

Страница 30: ...segunda bomba 9 Pegue un codo de 45 al tubo corto en la bomba de respaldo de CC Pegue un adaptador en Y al tubo corto en la bomba existente como se muestra en la ilustraci n del M todo 2 10 Pegue una...

Страница 31: ...tiva de la bater a La pantalla debe iluminarse en este momento Si se conecta de forma incorrecta sonar una alarma hasta que se corrija 4 Enchufe la bomba y los conectores del interruptor de flotador e...

Страница 32: ...l nea telef nica est conectada y que la Home Screen pantalla de inicio no tenga mensajes de error 2 Presione el bot n MENU men seguido de la opci n Phone Setup configuraci n del tel fono 3 Despl cese...

Страница 33: ...NTESTADORA AUTOM TICA CORREO DE VOZ EN LA MISMA L NEA TELEF NICA Para cancelar la secuencia de llamadas de alarma haga lo siguiente PASOS QUE DEBE REALIZAR 1 Realice la llamada al Sistema n mero de te...

Страница 34: ...E LA RED TELEF NICA Si este Sistema causa da o a la red telef nica la compa a telef nica le notificar con anticipaci n que puede ser necesaria la suspensi n temporal del servicio Pero si el aviso con...

Страница 35: ...lente El motor zumba pero la bomba no funciona 1 Bater a defectuosa 2 El impulsor est bloqueado 1 Verifique la bater a y reempl cela si el flujo es bajo o defectuoso 2 Desconecte la bomba retire la re...

Страница 36: ...cionamiento de menos de 1 hora 1 Corte de energ a 2 Corte de energ a extendido 1 Notifique a la compa a de servicios p blicos 2 Prepare una bater a de repuesto Cambie la bater a 1 La bater a tiene poc...

Страница 37: ...est configurado a 5 repiques 1 Haga una llamada al Sistema n mero de tel fono de la ubicaci n de la alarma deje sonar 3 tres veces cuelgue 2 Realice una segunda llamada al Sistema en 3 minutos el Sist...

Страница 38: ...as garant as impl citas o no permiten las exclusiones o limitaciones de da os incidentales o consecuentes de manera que las limitaciones mencionadas anteriormente pueden no aplicarse en su caso Esta g...

Страница 39: ...Notes Remarques Notas 39 Sp DF12VSM www blueangelpumps com...

Страница 40: ...Notes Remarques Notas 40 Sp Manuel de Instrucciones y Lista de Piezas www blueangelpumps com...

Отзывы: