background image

 

OPERATING INSTRUCTIONS

1.  To test the back-up pump, unplug the main pump and 

     transformer and fill sump with water until the water lifts the 

     bottom float therefore activating the back-up pump. Repeat 

     this process two times to be sure pump is operating 

     normally.
2.  If pump operates normally, plug the transformer into wall 

     outlet and plug the main pump back in. Verify the main 

     pump is operational by repeating step 1 above.

FCC STATEMENT

This equipment complies with Part 68 of the FCC rules and 

the requirements adopted by the ACTA (American Council 

for Terminal Attachments). On the inside cover of your unit 

is a label that contains, among other information, the FCC 

registration number for this product. If requested, this number 

The advanced notification system produces auto-dialer alerts 

and can also notify your 3rd party home security system 

provider (if available).  A qualified home security technician is 

required when making connections between the two systems.  

An access port is available on the back of the lid in which 

the qualified technician can properly connect the advanced 

notification system to the security system. (See Figure 5) 

At this time, you may wish to change the system settings.  

Since both the auto-dialer and security system cannot access 

the phone line at the same time, you must choose which 

system the software accesses first.  If you wish the security 

system to have first priority, on the main menu, scroll to and 

select the "SECURITY SETUP" option, select "Security has 

Priority" and hit "Enter" to confirm.  The factory default setting 

is "Back-up has Priority".
If you choose, you can test the security notification by 

simulating any of the security notification alerts. (See Figure 6)

 

 

Replace the inner shield once all connections and tests have 

been validated.

Security System Installation and Setup

 

Electric shock hazard. Disconnect 

 

power before servicing. Apply a fixed 

lock or tag to prevent unexpected application of power.

Figure 5 - Security system setup 

 

DO NOT overtighten screw.

must be provided to the telephone company.

PLUG AND JACK USE

A plug and jack used to connect this equipment to the premises 

wiring and telephone network must comply with the applicable 

FCC Part 68 rules and requirements adopted by the ACTA. 

A compliant modular plug is provided with this product. It is 

designed to be connected to a compatible modular jack that is 

also compliant. See installation instructions for details.

RING EQUIVALENCE NUMBER (REN)

The REN is used to determine the number of devices that may be 

connected to a telephone line. Excessive REN’s on a telephone line 

may result in the devices not ringing in response to an incoming 

call. In most, but not all areas, the sum of RENs should not exceed 

five (5.0). To be certain of the number of devices that may be 

connected to a line, as determined by the total REN’s, contact your 

local telephone company.

 

The REN for this product is listed on the 

inside of the controller lid with the FCC identifier. 

TELEPHONE NETWORK INTERFERENCES

If this System causes harm to the telephone network, the 

telephone company will notify you in advance that temporary 

discontinuance of service may be required. But if advance notice 

isn’t practical, the telephone company will notify the customer 

as soon as possible. Also, you will be advised of your right to 

file a complaint with the FCC if you believe it is necessary. The 

telephone company may make changes in its facilities, equipment, 

operations or procedures that could affect the operation of the 

equipment. If this happens, the telephone company will provide 

advance notice in order for you to make necessary modifications 

to maintain uninterrupted service. If the equipment is causing harm 

to the telephone network, the telephone company may request 

that you disconnect the equipment until the problem is resolved. 

If your home has specially wired alarm equipment connected to 

the telephone line ensure the installation of your System does not 

disable your alarm equipment. If you have questions about what 

will disable alarm equipment, consult your telephone company or a 

qualified installer.

ADVANCED NOTIFICATION  

MESSAGE ON UNIT SCREEN

PRIMARY PUMP STATUS 

AC Power Interrupted 

Primary Pump Suspect 

BACK-UP DC PUMP STATUS 

DC Pump In Operation 

DC Pump Not Operable (Failed Test) 

Check Floats For Debris 

Capacity Overflow Possible

DC Impeller Locked 

BATTERY TRANSFORMER 

Transformer Bad 

Blown Controller Fuse 

MICROPROCESSOR CONTROLLER 

CONDITION 

12  V BATTERY STATUS  

DC Pump Under Test 

Battery Fully Charged 

Battery 80% Charged 

Battery 60% Charged  

Battery 40% Charged 

Battery 20% Charged 

Battery Dead 

Battery Condition Questionable 

CALL PHONE

AUDIBLE ALARM

SECURITY SYSTEM

Reverse Polarity 

Figure 6 -Notification alerts chart 

 

The inner shield will have to be removed during 

 

this step. Be sure not to damage any 

 

components on the control board. 

            

      FOR SIGNAL 

USAGE ONLY. NC/NO Output: 

12 Volt DC, 2 amp max. 

2.  The extension cord must have a ground wire and plug pin 

     and be connected to a properly functioning GFCI 

     receptacle.
3.  Make sure the connection between the transformer and 

     extension cord are elevated off the floor.

DF12VSM

9

www.blueangelpumps.com

Содержание DF12VSM

Страница 1: ...es not include 12 Volt DC deep cycle battery phone jack phone line pipe and necessary fittings Float Switch Security DC Pump Requires active telephone land line service STEP 2 DISCONNECT POWER If the...

Страница 2: ...Notes 2 Operating Instructions and Parts Manual www blueangelpumps com...

Страница 3: ...lure to follow these instructions WILL result in bodily injury or death Electric shock hazard Disconnect power before servicing Apply a fixed lock or tag to prevent unexpected application of power Ele...

Страница 4: ...low the pump or check valve to be removed easily for servicing 8 Check valve is recommended for effective operation of system The remainder of the discharge pipe installation will vary depending on in...

Страница 5: ...etal pipe is required for permanent installation 9 Glue a 45 elbow to the short pipe on the Back Up DC Pump Glue a Y adapter to the short pipe on the existing pump as shown in illustration for Method...

Страница 6: ...negative terminal of the battery The display should be lit up at this time If connected improperly an alarm will sound until corrected 4 Plug the pump and float switch connectors into the 12 Volt Adva...

Страница 7: ...umber hit ENTER then select the TEST option The system will immediately dial the desired phone number Upon answering the unit will play the following message This is a test of the back up system It wi...

Страница 8: ...cond time within three minutes The System keeps track of all the rings from the previous calls accumulates them until the total ring count matches its ring count number 5 or 10 and then it will answer...

Страница 9: ...determine the number of devices that may be connected to a telephone line Excessive REN s on a telephone line may result in the devices not ringing in response to an incoming call In most but not all...

Страница 10: ...ber at alarm location let ring three 3 times hang up 2 Make a second call to the System within 3 minutes the System will answer on the second ring 3 rings 2 rings System answers on fifth 5th ring 3 Li...

Страница 11: ...place if low or defective 5 Check to make sure the back up pump is not air locked Locate the vent hole inspect and clear the hole using a pipe cleaner Pump Cycles Too Frequently 1 Check valve problem...

Страница 12: ...allow limitations on how long an implied warranty lasts or do not allow the exclusions or limitations of incidental or consequential damages so the above lim i ta tions might not apply to you This li...

Страница 13: ...Interrupteur flotteur S curit Pompe c c Requiert un service de ligne terrestre t l phonique actif TAPE 2 METTRE HORS TENSION Si la source de courant n est pas visible verrouiller en position ouverte a...

Страница 14: ...Remarques 14 Fr Instructions d Utilisation et Manuel de Pi ces www blueangelpumps com...

Страница 15: ...que NE PAS marcher sur un sol mouill avant que le courant ne soit coup Faire appel un lectricien agr pour effectuer l entretien conform ment au Code national de l lectricit et aux codes locaux PROPOSI...

Страница 16: ...ser des pratiques de plomberie s res pour acheminer le tuyau de d charge vers un mur ext rieur par le chemin le plus court R duire le nombre de coudes au maximum dans la mesure o qu ils r duisent le d...

Страница 17: ...er un coude de 45 au tuyau court de la pompe de secours c c Coller un adaptateur en Y au tuyau court de la pompe existante comme indiqu sur l illustration de la m thode 2 10 Coller une section courte...

Страница 18: ...de la batterie puis connecter le fil noir sur la borne n gative de la batterie L affichage devrait alors s allumer En cas de branchement incorrect une alarme se d clenche jusqu ce que le probl me soit...

Страница 19: ...minuteries et toutes les erreurs sont effac es de la m moire du syst me maintenir le bouton RESET r initialisation enfonc pendant au moins 3 5 secondes 2 Appuyer sur le bouton MENU suivi de l option...

Страница 20: ...RIE VOCALE EST INSTALL SUR LA M ME LIGNE T L PHONIQUE Pour annuler la s quence d appel d alarme sortant suivre les tapes suivantes TAPES SUIVRE 1 Appeler le syst me le num ro de t l phone du site de l...

Страница 21: ...dant lorsqu un avis pr alable n est pas possible la compagnie de t l phone avisera le client d s que possible En outre vous serez inform de votre droit d poser une plainte aupr s de la FCC si vous le...

Страница 22: ...g e 60 Batterie charg e 40 Batterie charg e 20 Batterie d charg e tat de la batterie sujet caution APPELT L PHONIQUE ALARME SONORE SIGNALDU SYST ME DE S CURIT Inverser la polarit Figure 6 Tableau des...

Страница 23: ...terie faible ou d fectueuse 3 Interrupteur flotteur coinc 4 Fusible d fectueux ou grill 1 V rifier toutes les connexions 2 V rifier la batterie et la remplacer si elle est faible ou d fectueuse 3 S as...

Страница 24: ...site de l alarme laisser sonner trois 3 sonneries puis raccrocher 2 Appeler le syst me une seconde fois dans les 3 minutes qui suivent le syst me r pondra au bout e deux sonneries 3 2 sonneries le sys...

Страница 25: ...clusion ou la limitation des dommages accessoires ou indirects en cons quence les limitations pr c dentes peuvent ne pas s appliquer tous les cas Cette garantie limit e vous conf re des droits juridiq...

Страница 26: ...dor Seguridad Bomba CC Requiere un servicio de tel fono de l nea activado PASO 2 DESCONECTE LA ENERG A Si la protecci n de desconexi n no est a la vista tr nquela en la posici n abierta y etiqu tela p...

Страница 27: ...Notas 27 Sp DF12VSM www blueangelpumps com...

Страница 28: ...u cable de corriente PUEDEN contener qu micos incluido plomo que son conocidos por el Estado de California como causantes de c ncer y defectos de nacimiento u otros da os reproductivos L vese las mano...

Страница 29: ...n para un funcionamiento eficaz del sistema El resto de la instalaci n de la tuber a de descarga variar dependiendo de las circunstancias individuales Dirija la tuber a de descarga hacia una pared ex...

Страница 30: ...segunda bomba 9 Pegue un codo de 45 al tubo corto en la bomba de respaldo de CC Pegue un adaptador en Y al tubo corto en la bomba existente como se muestra en la ilustraci n del M todo 2 10 Pegue una...

Страница 31: ...tiva de la bater a La pantalla debe iluminarse en este momento Si se conecta de forma incorrecta sonar una alarma hasta que se corrija 4 Enchufe la bomba y los conectores del interruptor de flotador e...

Страница 32: ...l nea telef nica est conectada y que la Home Screen pantalla de inicio no tenga mensajes de error 2 Presione el bot n MENU men seguido de la opci n Phone Setup configuraci n del tel fono 3 Despl cese...

Страница 33: ...NTESTADORA AUTOM TICA CORREO DE VOZ EN LA MISMA L NEA TELEF NICA Para cancelar la secuencia de llamadas de alarma haga lo siguiente PASOS QUE DEBE REALIZAR 1 Realice la llamada al Sistema n mero de te...

Страница 34: ...E LA RED TELEF NICA Si este Sistema causa da o a la red telef nica la compa a telef nica le notificar con anticipaci n que puede ser necesaria la suspensi n temporal del servicio Pero si el aviso con...

Страница 35: ...lente El motor zumba pero la bomba no funciona 1 Bater a defectuosa 2 El impulsor est bloqueado 1 Verifique la bater a y reempl cela si el flujo es bajo o defectuoso 2 Desconecte la bomba retire la re...

Страница 36: ...cionamiento de menos de 1 hora 1 Corte de energ a 2 Corte de energ a extendido 1 Notifique a la compa a de servicios p blicos 2 Prepare una bater a de repuesto Cambie la bater a 1 La bater a tiene poc...

Страница 37: ...est configurado a 5 repiques 1 Haga una llamada al Sistema n mero de tel fono de la ubicaci n de la alarma deje sonar 3 tres veces cuelgue 2 Realice una segunda llamada al Sistema en 3 minutos el Sist...

Страница 38: ...as garant as impl citas o no permiten las exclusiones o limitaciones de da os incidentales o consecuentes de manera que las limitaciones mencionadas anteriormente pueden no aplicarse en su caso Esta g...

Страница 39: ...Notes Remarques Notas 39 Sp DF12VSM www blueangelpumps com...

Страница 40: ...Notes Remarques Notas 40 Sp Manuel de Instrucciones y Lista de Piezas www blueangelpumps com...

Отзывы: