TROUBLESHOOTING SUGGESTIONS
10
SYMPTOM
POSSIBLE CAUSE
SUGGESTED REMEDY
Water won’t heat
Brewer unplugged or circuit breaker
tripped
Check power supply cord
Check / reset circuit breaker
Thermostat set too low
Set for desired temperature
Hi-Limit thermostat tripped
Allow to cool, Reset hi-limit (8786,
8788)
Damaged internal component or
wiring
Examine wiring & connectors,
thermostat and heating element,
Repair/replace as needed
Pourover - no water or too little water
added at startup
Be sure to add sufficient water
Coffee level low (pour-over)
Not enough water poured in
Increase water amount
Too much coffee grounds
Adjust amount of grounds
Coffee level too high or low
(automatic)
Timer out of adjustment
Adjust timer
Brew chamber overflows
Too many filter papers or wrong filter
paper
Use one (1) genuine Bloomfield
filter per brew
Brew chamber dispense hole plugged Thoroughly clean brew chamber
Too much coffee or too fine a grind
Adjust coffee amount and grind
Sprays water from brew head
Spray gasket improperly installed
Check/reinstall gasket on INSIDE
of brew head
Spray disk plugged
Clean spray disk
No brew (automatic)
Water supply OFF
Turn water supply ON
Solenoid strainer plugged
Clean strainer
Water filter (if used) plugged
Replace filter element
Bad BREW switch
Replace switch
Damaged internal component or
wiring
Examine wiring & connectors,
brew switch and solenoid, Repair/
replace as needed
No flow from hot water faucet
Faucet valve turned OFF
Turn faucet valve ON
Faucet plugged
Disassemble faucet, clean
Poor coffee quality
Water not hot enough
Adjust water temp 195-205ºF
Keep brewer, airpots and servers clean. Install a taste and odor filter in
water supply, and replace cartridges regularly. Use a quality coffee with a
consistent roast. Use proper grind and amount of coffee per brew.
622 2M-75854 Owners Manual Gourmet 1000
Airpot/Thermal
622 2M-75854 Owners Manual Gourmet 1000
Airpot/Thermal
Содержание 8778
Страница 25: ...WIRING DIAGRAM continued 23 622 2M 75854 Owners Manual Gourmet 1000 Airpot Thermal...
Страница 26: ...622 2M 75854 Owners Manual Gourmet 1000 Airpot Thermal NOTES...
Страница 27: ...NOTES 622 2M 75854 Owners Manual Gourmet 1000 Airpot Thermal...
Страница 28: ...10 Sunnen Drive St Louis MO 63143 telephone 888 356 5362 fax 314 781 2714 www wellsbloomfield com...