background image

CAUTION: 

CHEMICAL BURN 
HAZARD

Deliming chemicals may be 

caustic.  Wear appropriate 

protective gloves and goggles 

during this procedure.

Never siphon deliming      

chemicals or solutions by 

mouth.

This operation should only be 

performed by qualified and    

experienced service personnel.

IMPORTANT: 

 DO NOT 

spill, splash or pour water or 

deliming solution into or over 

any internal component other 

than the inside of the water 

tank.

IMPORTANT: 

 DO NOT allow 

any internal components to 

come into contact with the     

deliming solution.  Take care to 

keep all internal components 

dry.

NOTE:

  Repeat steps 4 thru 5 

as required to remove all scale 

and lime build-up.

NOTE: 

 Normally, silicone 

hoses do not need to be  

delimed.  Should deliming 

hoses become necessary, 

Bloomfield recommends 

replacing the hoses.

PROCEDURE:  Delime the Water Tank 

PRECAUTIONS:    Disconnect brewer from electric power. 

 

Allow brewer to cool.

FREQUENCY:    As required (Brewer slow to heat)

TOOLS:   

Deliming Solution

 

Protective Gloves, Goggles & Apron

 

Mild Detergent, Clean Soft Cloth or Sponge

 

Bristle Brush, Bottle Brush

 

Large Sink (or other appropriate work area)

1.  Disconnect brewer from the electrical supply.  For automatic  

brewers, turn off the water shut-off valve and disconnect the 

water supply line from the brewer inlet fitting.

2.  Remove the tank lid assembly as described on page 13.
3.   Remove the water tank from the brewer body by lifting 

straight up.  Empty all water from the tank.  Set the tank back 

into the brewer.

4.  Mix 2 quarts of deliming solution according to the 

manufacturer’s directions.  Carefully pour the deliming 

solution into the water tank.  Lower the lid assembly back 

onto the tank.  Allow to sit for 30 minutes, or as directed by 

the manufacturer.

5.  At end of soaking period, remove lid assembly from tank.  

Thoroughly rinse internal components of lid assembly with 

clear water.  Using a stiff bristle brush, scrub the heating 

element (and faucet water coil on automatic brewers) to 

remove lime and calcium build-up.  Rinse with clean water.  

Store lid assembly in a safe location.

6.  Remove the tank from the brewer and empty.  Using a stiff 

bristle brush, scrub the interior of the water tank to remove 

lime and calcium build-up.  Rinse with clean water.  

7.  Set the tank back into the brewer.  Reassemble the tank lid 

to the water tank.  Make sure the gasket is properly in place, 

and then reinstall the hold-down strap.

8.  Reinstall wiring to heating element and thermostat.  Reinstall 

the hi-limit thermostat (if removed).  For automatic brewers, 

reassemble piping for the faucet.  Verify that all internal 

components are dry, and then reinstall the top panel.

9.   Reconnect brewer to electrical supply and, for automatic 

brewers, reconnect water supply.

10. Install the brew chamber without filter paper or grounds. 

Run at least three full brew cycles and discard all water     

generated.

11. Brewer is ready to use.

SERVICING INSTRUCTIONS (continued)

16

622 2M-75854 Owners Manual Gourmet 1000 

Airpot/Thermal

622 2M-75854 Owners Manual Gourmet 1000 

Airpot/Thermal

Содержание 8778

Страница 1: ...ellsbloomfield com BLOOMFIELD INDUSTRIES p n 2M 75854 Rev F M622 110501 622 OWNERS MANUAL for AIRPOT THERMAL SERVER COFFEE BREWERS MODELS 8778 8780 8782 8783 8785 8786 8788 Includes Installation Use C...

Страница 2: ...y decanters excluded THE FOREGOING OBLIGATION IS EXPRESSLY GIVEN IN LIEU OF ANY OTHER WARRANTIES EXPRESSED OR IMPLIED INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURP...

Страница 3: ...DIAGRAMS 22 SPECIFICATIONS 1 622 2M 75854 Owners Manual Gourmet 1000 Airpot Thermal MODEL STYLE VOLTS WATTS AMPS 1 POWER SUPPLY CORD 8778 THERMAL 120V 1800 15 NEMA 5 15P 8778CAk 120C 1500 12 5 NEMA 5...

Страница 4: ...1 Features Operating Controls 2 IL1705 NOT AVAILABLE ON MODELS 8782 or 8785 AIROT BREWING POSITION HOT WATER FAUCET BREW SWITCH POUR OVER COVER POUR OVER OPENING READY TO BREW LIGHT 622 2M 75854 Owner...

Страница 5: ...lishments where all operators are familiar with the appliance use limitations and associated hazards Operating instructions and warnings must be read and understood by all operators and users Except a...

Страница 6: ...your water pressure exceeds 90 PSI at anytime a pressure regulator must be installed in the water supply line to limit the pressure to not more than 90 PSI in order to avoid damage to lines and solen...

Страница 7: ...LLATION INSTRUCTIONS REFER TO ELECTRICAL SPECIFICATIONS Page 1 Check the nameplate to determine correct electrical service required for the Brewer to be installed IMPORTANT Before connecting to electr...

Страница 8: ...cover then pour warm tap water into the pour over opening until water flows from the brew head When water stops dripping from the brew head empty the container Once the tank is full of water connect...

Страница 9: ...water tank This forces an identical amount of hot water out of the tank and through the spray head into the brew chamber The solenoid uses a flow control device so that flow is consistent between 20...

Страница 10: ...ver identical to the one being used with tap water Lift the pour over cover and pour the entire contents of the container into the pour over opening which will fill the basin Water from the basin will...

Страница 11: ...d a mild detergent A bristle brush may be used to clean the inside Rinse with clean water and allow to air dry 8 Wipe the exterior of the brewer with a soft clean cloth or sponge moistened with clean...

Страница 12: ...w Brew chamber dispense hole plugged Thoroughly clean brew chamber Too much coffee or too fine a grind Adjust coffee amount and grind Sprays water from brew head Spray gasket improperly installed Chec...

Страница 13: ...wo screws at the bottom and a retaining lip at the top SOLENOID DOOR Remove solenoid door to access solenoid and plumbing connections Solenoid door is held by two screws and a retaining lip Fig 9 Acce...

Страница 14: ...and reinstall vent tube Fig 10 Checking and Adjusting Brew Temperature CAUTION SHOCK HAZARD These procedures involve exposed electrical circuits These procedures are to be performed by qualified tech...

Страница 15: ...n plug REMOVE TANK LID ASSEMBLY Unplug brewer or turn circuit breaker OFF Turn OFF water supply Remove top panel Pull vent tube and inlet elbow out of basin pan Pull water inlet tube out of basin pan...

Страница 16: ...se fitting b Pressure on the white ring toward the metal ferrule releases the clinch ring allowing the hose to be easily slid off of the solenoid bypass outlet c Install hose on new valve by pressing...

Страница 17: ...valve is turned OFF Remove tank lid assembly per above Remove two hex nuts hot water coil to cover Pull coil from mounting holes Reassemble in reverse order REPAIR HOT WATER FAUCET Remove top panel an...

Страница 18: ...body by lifting straight up Empty all water from the tank Set the tank back into the brewer 4 Mix 2 quarts of deliming solution according to the manufacturer s directions Carefully pour the deliming s...

Страница 19: ...63 2T 47499 THERMOSTAT HI LIMIT ALL exc 8786 8788 2T 70716 THERMOSTAT HI LIMIT RESET 8786 8788 66 2V 70144 WATER INLET TUBE ALL 66a 2C 70146 NUT HEX 4 40 SS ALL 66b 2C 70145 SCREW 4 40 x 1 PAN HEAD A...

Страница 20: ...FLAT 15 32 x 1 1 8 x 1 16 SS 8780 8782 8786 8788 29 WS 82556 FAUCET ASSEMBLY PRESSURE 8780 8782 8786 8788 33 2I 70139 GASKET SPRAY HEAD ALL 34 A6 82727 SPRAY DISK EMBOSSED ALL 34a A6 70163 RETAINER SP...

Страница 21: ...EU 230V UNITS 37 2K 70215 STRAIN RELIEF 8778 80 82 83 85 2K 70648 STRAIN RELIEF SMALL UK EU 230V UNITS 43 2E 70709 TERMINAL BLOCK 4P 8786 8788 45 2E 75753 SOLENOID W BYPASS 120V 50 GPM 8780 8782 8786...

Страница 22: ...EXPLODED VIEW PARTS LIST continued CABINET COMPONENTS 21 IL1711 622 2M 75854 Owners Manual Gourmet 1000 Airpot Thermal...

Страница 23: ...8782TFL 8785 AL 8785 ALP A6 74693 BODY WRAP 8786 1086 8786TF A6 74773 BODY WRAP 8788 8788AF 102 A6 72292 PANEL FRONT 8780TF 8786TF 8778 T A6 74811 8782AF 8785 A 8788AF DD 74900 8782AFL A6 74793 8782TF...

Страница 24: ...RING DIAGRAM BROWN 230V BLACK 14 GA WHITE 14 GA BLUE 230V 120VAC POUR OVER 1800 WATT MODELS 8778 8783 8785 1500 WATT Canadian MODELS 8778CA 8783CA 8785CA 120VAC AUTOMATIC 1800 WATT MODELS 8780 8782 87...

Страница 25: ...WIRING DIAGRAM continued 23 622 2M 75854 Owners Manual Gourmet 1000 Airpot Thermal...

Страница 26: ...622 2M 75854 Owners Manual Gourmet 1000 Airpot Thermal NOTES...

Страница 27: ...NOTES 622 2M 75854 Owners Manual Gourmet 1000 Airpot Thermal...

Страница 28: ...10 Sunnen Drive St Louis MO 63143 telephone 888 356 5362 fax 314 781 2714 www wellsbloomfield com...