SERVICING INSTRUCTIONS (continued)
13
IMPORTANT:
Water pressure
must be between 20 p.s.i and
90 p.s.i. flowing pressure.
If water pressure exceeds this
value, or if water pressure
varies greatly, a pressure
regulator must be installed in
the water supply line.
IMPORTANT:
Before setting
assembly into tank, make sure
tank lid gasket is properly
seated on flange of lid.
DO NOT OVER-TIGhTEN
.
IMPORTANT:
If mounting thermostat
p/n WS-8512-51, be sure to
place a new seal washer below
the fitting on the capillary line.
If replacing gray-bodied thermo
with p/n WS-8512-51, be sure to
remove tube from thermowell.
TIMER ADJUSTMENT
The amount of water dispensed automatically during a brew cycle
is controlled by the timer.
Place empty decanter under brew chamber. Press BREW
button. Brewer should dispense one decanter of water. To
adjust amount:
Remove brew chamber and button plug. Adjust knob on timer;
clockwise increases time. Run several cycles to check amount
of water delivered. Replace button plug.
REMOVE TANK LID ASSEMBLY
Unplug brewer or turn circuit breaker
OFF
. Turn
OFF
water
supply. Remove top panel. Pull vent tube and inlet elbow out of
basin pan.
Pull water inlet tube out of basin pan. Remove basin pan.
On models with faucet, disconnect inlet pipe at faucet shut-off
valve and outlet pipe at faucet.
Disconnect all wiring from thermostat, hi-limit, and heating
element.
Loosen center screw on tank hold-down bracket. Remove
hold-down bracket by sliding short slotted end off of locking stud
and lifting it off. Remove cover assembly by lifting it straight up.
Reassemble in reverse order.
REPLACE THERMOSTAT
Unplug brewer or turn circuit breaker
OFF
. Turn
OFF
water
supply. Remove top panel.
Disconnect all wiring from thermostat only. Loosen and free
jam nut from pass-thru fitting securing temperature sensing bulb.
Remove two screws holding thermostat to bracket.
Lift out thermostat, sensing bulb and thermostat gasket.
Push sensing bulb into tank lid thermowell until fitting seats.
Tighten capillary lock nut only enough to ensure no water
leakage. Excessive tightening is not necessary.
Reassemble in reverse order.
622 2M-75854 Owners Manual Gourmet 1000
Airpot/Thermal
622 2M-75854 Owners Manual Gourmet 1000
Airpot/Thermal
Содержание 8778
Страница 25: ...WIRING DIAGRAM continued 23 622 2M 75854 Owners Manual Gourmet 1000 Airpot Thermal...
Страница 26: ...622 2M 75854 Owners Manual Gourmet 1000 Airpot Thermal NOTES...
Страница 27: ...NOTES 622 2M 75854 Owners Manual Gourmet 1000 Airpot Thermal...
Страница 28: ...10 Sunnen Drive St Louis MO 63143 telephone 888 356 5362 fax 314 781 2714 www wellsbloomfield com...