SERVICING INSTRUCTIONS
ACCESS PANELS
TOP PANEL:
Remove top panel to access hot water tank, thermostat, heating
elements, brew circuit tubing, faucet valve and piping.
Top panel is held by two screws at the rear and a retaining lip at
the front.
FRONT PANEL:
Remove front panel to access timer, terminal block and solenoid.
Front panel is held by two screws at the bottom and a retaining
lip at the top.
SOLENOID DOOR:
Remove solenoid door to access solenoid and plumbing
connections.
Solenoid door is held by two screws and a retaining lip.
Fig. 9 Access Panels
CAUTION:
SHOCK HAZARD
Opening access panels or
removing warmer plates on this
brew may expose uninsulated
electrical components.
Disconnect brewer from
electrical power before
removing any panel or warmer
plate.
11
TOP
PANEL
FRONT
PANEL
BUTTON
PLUG
SOLENOID
DOOR
TIMER
IL1707