background image

Extended Warranty Program 

STANDARD TERMS & CONDITIONS OF THE EXTENDED WARRANTY 

A.      THE EXTENDED WARRANTY AGREEMENT (EWA) 

If during the period following the expiration of the Blonder Tongue Manufacturers’ Standard Warranty ( Copy Included) the products which constitute the subject 

matter of the extended warranty, manifest any manufacturing or similar such defects then Blonder Tongue shall at its option repair or replace the product.  It is 

emphasized that the extended warranty is in effect an extension of the Blonder Tongue Warranty and covers the items stipulated in Paragraph B to the exclusion of 

the terms in Paragraph C of this agreement.  Eligibility to purchase EW is limited to 90 days following initial shipment on selected products of sufficient value. 

The product/products included in this extended warranty agreement are listed in the invoice that accompanies the EWA.  Term of the extension will be ______ 

year(s).  Purchase Order is required for extended warranty coverage. 

 B.     WHAT IS COVERED? 

1.

If a product has been determined to have failed, which falls within the Terms & Conditions of this EWA, Blonder Tongue Inc. may at its sole discretion

repair, modify or replace its component parts that are defective at 100% coverage for parts and labor.

2.

A loaner unit may be available on request; PO required.

3.

Product is manufactured by Blonder Tongue.

4.

Extended warranty period is up to and not to exceed 24 months and sold in increments of 12 months.  Order # 9981 for 1 year and #9982 for 2 year

extensions.

5.

Return of repair or replaced product shipping costs for ground shipments.

6.

Firmware upgrades at no charge with automatic notification.

C.      WHAT IS NOT COVERED? 

1.

The warranty does not cover any defects caused by foreign objects /connection errors .

2.

Use other than by the customer at the declared address appearing in this document.

3.

Failure by the end user to comply with the manufacturers’ instructions for installation, maintenance or use.

4.

The use of accessories which have not been approved by Blonder Tongue.

5.

The application and/or use of any incorrect or abnormal electrical supply to the product.

6.

Any defect in wiring or electrical connections which does not form part of the product at the time of the original purchase.

7.

Neglect, misuse, or willful abuse of the product.

8.

Any repairs or attempted repairs of the product by any person other than Blonder Tongue Service Department.

9.

Any modification of the product by any person other than Blonder Tongue Service Department.

10. Fire, flood, war, civil disturbance, industrial action, acts of God or any other causes beyond the reasonable control of Blonder Tongue.

11. Any defect caused by lightning strike or power surges.

12. Shipping costs to return products to Blonder Tongue for warranty service.

13. Blonder Tongue will not in any circumstances be liable for any consequential loss or damages suffered by the customer whether directly or indirectly 

related defect in the product to the extent permissible by law.

14. Repairs may not be effected without prior authorization from Blonder Tongue Laboratories.

D.      GENERAL 

1.

The customer shall notify Blonder Tongue Laboratories in writing within ten days of any change of his or her address.

2.

Customer must provide original 

purchase receipt

 and 

serial number

 to initiate extended warranty coverage.

3.

The fee paid for the warranty is not refundable under any circumstances unless cancelled within seven days of purchase.

4.

The customer shall take all reasonable precautions to maintain the product is maintained in good working order.

5.

The warranty contract ceases to exist if the product is replaced or a credit is given to the customer. Any monies paid for the warranty contract are forfeited

and not refundable. This is only applicable when the product is out of the manufacturer’s warranty.

6.

The extended warranty period as stated on the Extended Warranty Agreement shall be the governing period notwithstanding any additional supplier

warranty on specific components.

7.

The warranty shall in no way effect the terms and conditions of the sale agreement in terms of which the customer bought the product.

8.

The extended warranty is limited to the terms and conditions herein contained

9.

No agreement, varying, adding to, amended, deleting, or cancelling this warranty shall be effective unless given in writing (email is acceptable) and signed 

by or on behalf of both parties.

10. The cost of the extended warranty is 8% of the purchase price for a 1 or 2 year extension beyond the Blonder Tongue standard warranty.  e.g.  A product 

price of $1000 will be $80 for the 1

st

 year (12 mos) and additional $80 for 2 year (24 mos) extension for a total of $160.

11. Warranty product return postage paid to:

Blonder Tongue Laboratories, Inc.

Attn:  Warranty Service Dept. 

1 Jake Brown Road 

Old Bridge, NJ  08857

Contact Blonder Tongue at 800-523-6049 

ext. 

555 to order extended warranty service.

Содержание Clearview 4:2

Страница 1: ...All Rights Reserved Specifications subject to change without notice All trademarks are property of their respective owners H 264 to MPEG 2 HD Transcoder for up to 24xSPTS Channels Blonder Tongue Labs Inc ISO 9001 2015 Certified P N 651245300A Rev 112119 Clearview 4 2 User Manual ...

Страница 2: ...e or Stock Number in the search field Upon reaching the product page the User Manual download link will be located beneath the product image Firmware Updates are available under Tech Support in the Resources section of the website General instructions for the FTP site as well as updating your firmware are provided on this page We recommend that you write the following information in the spaces pro...

Страница 3: ...ALLATION AND POWER UP 8 SECTION 4 CONNECTING TO A PC LAPTOP 8 4 1 ETHERNET ACCESS 8 4 2 ACCESSING THE USER INTERFACE VIA THE WEB BROWSER 9 SECTION 5 BASIC CONFIGURATION 10 5 1 STATUS SCREEN 10 5 2 SYSTEM SCREEN 11 5 3 TIME SCREEN 13 5 4 ADMIN SCREEN 14 SECTION 6 TRANSCODERS 15 6 1 TRANSCODERS STATUS SCREEN 15 6 2 TRANSCODERS SETTINGS SCREEN 15 SECTION 7 FIRMWARE UPDATES AND TROUBLESHOOTING 18 7 1 ...

Страница 4: ... This reminder is provided to call the CATV System Installer s attention to Article 820 40 of the NEC that provides guidelines for proper grounding and in particular specifies that the cable ground shall be connected to the grounding system of the building as close to the point of cable entry as practical TO REDUCE THE RISK OF ELECTRICAL SHOCK DO NOT REMOVE COVER FROM THIS UNIT NO USER SERVICEABLE...

Страница 5: ...rview 4 2 provides an easy to use interface and the ability to download and upload a configuration file for multi unit deployments TheClearview4 2canalsobeconfiguredtoreceiveuptotwenty four 24 H 264AES 128encryptedIPchannelsfromTechnicolor COM3000 2000 devices The Clearview 4 2 decrypts the AES 128 content Transcodes the decrypted H 264 content into MPEG 2 while preserving the forensic watermarkin...

Страница 6: ... temporarily resets the IP address Usernames and Passwords to Factory Default Activation is indicated by the Power LED blinking twice Default values are as follows IP address 172 16 70 1 Username Admin case sensitive Password pass case sensitive NOTE Resetting power will revert IP and login credentials back to what has been configured by the user The effects of activating the IP Reset feature are ...

Страница 7: ...th Sync Byte Bit Rate TS Supported CODEC Resolution Audio Routing Protocol ISO IEC 13818 1 Watermarking 188 bytes 0x47 Constant 24 SPTS MPEG 2 480i 30 fps 480p 30 60 fps 720p 30 60 fps 1080i 30 fps Pass through Unicast Output Alarms Monitoring Control Local Monitoring Local Control 1x Power LED 1x Temperature LED 24x Status LEDs 1x IP Reset button Remote Monitoring Control 1x RJ45 1000Base T GbE G...

Страница 8: ...me or Firefox browser Before you can communicate with the unit you must configure your computer s IP address to be in the same subnet as the units default IP address To do so follow these steps Connect one end of the Ethernet cable to the Control port on the unit front panel interface Connect the other end of the Ethernet cable to your computer The factory default IP address of the Control port is...

Страница 9: ... Section 4 1 before proceeding as follows Figure 4 2a Login Screen As shown in Figure 4 2b under the Page Header the following Navigation tabs and links will appear Navigation bar left side Status System Time Transcoders Status and Transcoders Settings Navigation bar right side Log and Firmware Update In addition in the upper right corner above the navigation the user can access the Admin screen t...

Страница 10: ...ach system component The data is detailed as follows Device Indicates the following system components Host is the Clearview 4 2 system XC1 XC12 display information for each transcode pair These will populate other data as the pairs are set up and enabled When a numbered transcode pair is not available the row will display as empty Fans displays data for each of the four system fans on the chassis ...

Страница 11: ...s The Log Messages sections will show the 10 most recent entries to the system log For a full view of all messages please see the Log tab The user can click on the Auto Refresh checkbox to enable that function See Section 7 2 for more information on types of messages Reference The reference link under this section points to the Blonder Tongue website 7 8 5 2 System Screen System Figure 5 2 next pa...

Страница 12: ...e identifier assigned to the network IP Address the static IP address that is assigned to the unit allowing the user to access it via the web interface Pressing the IP reset button temporarily returns unit to factory default of 172 16 70 1 Subnet Mask the subnet mask allows the user to access the unit from another network via the web interface Factory Default is 255 255 255 0 for local subnet Defa...

Страница 13: ...change ie Eastern Standard Time and Eastern Daylight Time 1 2 Figure 5 3a Current Time at Page Load 1 2 Figure 5 3b Time Settings 3 4 Time Settings Time Zone user is able set the time zone shown in UTC format Time Clicking the button will synchronize the Clearview time to Client time This requires that the selected time zone and client system time are correct After synchronization the Clearview ti...

Страница 14: ...only used when changing the current Administrator s password 16 characters maximum The password will not be displayed Factory Default pass Verify Password is required when changing the current Administrator s password It MUST match the Password field and will not be displayed Click the button to apply changes to the User Configuration 1 2 3 4 Figure 5 4 User Configuration 1 2 3 4 Custom NTP Server...

Страница 15: ...ual status of the pipeline is also shown on the left side When hovering over a Transcode block the corresponding status table to the right highlights 6 2 Transcoders Settings Screen Transcoders Settings Figure 6 2a is a read only screen which displays information about the input and output streams Figure 6 1 Transcoders Status Screen Figure 6 2a Transcoders Settings Screen Full View ...

Страница 16: ...ame Output Stream URI The user can configure the URI Output stream settings Protocol IP and Port The IP can be found on the QAM page of the COM s user interface The Port number is derived from the Port formula on the COM s QAM page Channel IP and Port The Overview page lists the output IP and Port for each channel EdgeQAM Modulator The IP address of the COM unit s QAM modulator The Clearview 4 2 t...

Страница 17: ...17 Clearview 4 2 User Manual 6 2 Transcoders Settings Screen continued Figure 6 2c COM2000 Overview Page 10 Figure 6 2d COM2000 QAM Page 11 12 ...

Страница 18: ...irmware updates are complete the user can remove the loaded file by clicking the button shown on Figure 7 1b next to the Upload File button under Firmware Update Files Check Firmware Version to ensure you have the latest firmware To determine if a new firmware update has been released please go to our website at www blondertongue com page resources tech support firmware updates Click the Download ...

Страница 19: ...appear in green text and indicates an event was logged where an operation was successful Warning messages appear in dark orange text and indicates an event was logged pertaining to an issue that did not cause a loss of service Error messages appear in bold red text and indicates an event was logged that caused or may cause loss of service Alarm messages appear as bold white text on a red backgroun...

Страница 20: ...20 Clearview 4 2 User Manual 7 3 Technical Support For additional technical support please contact us at 1 800 523 6049 between the hours of 8am and 5pm EST ...

Страница 21: ...21 Clearview 4 2 User Manual ...

Страница 22: ...22 Clearview 4 2 User Manual NOTES ...

Страница 23: ...y any person other than Blonder Tongue Service Department 9 Any modification of the product by any person other than Blonder Tongue Service Department 10 Fire flood war civil disturbance industrial action acts of God or any other causes beyond the reasonable control of Blonder Tongue 11 Any defect caused by lightning strike or power surges 12 Shipping costs to return products to Blonder Tongue for...

Страница 24: ...TIVE DIRECT OR SPECIAL DAMAGES BASED UPON BREACH OF WARRANTY BREACH OF CONTRACT NEGLIGENCE STRICT TORT LIABILITY OR OTHERWISE OR ANY OTHER LEGAL THEORY ARISING DIRECTLY OR INDIRECTLY FROM THE SALE USE INSTALLATION OR FAILURE OF ANY PRODUCT ACQUIRED BY BUYER FROM BT All claims for shortages defects and non conforming goods must be made by the customer in writing within five 5 days of receipt of mer...

Отзывы: