6.11 "Admin" Screen (continued)
11
Using the “Static until DHCP” setting when the
DASHBOARD is not being used
may cause communications problems
should a DHCP server ever be present on the IP control network.
In case the unit picks up a DHCP address and can no longer be communicated with because of an unknown IP address
assigned, do the following:
1. Disconnect the unit from the IP network.
2.
Reset the IP via the front panel button
3. Access unit via default IP address (172.16.70.1).
4.
Go to Admin page and change Control Port DHCP to “Static”.
5. Enter in a Control Port IP address based on network requirements.
Control Port IP Address:
is the static IP address that is assigned to the unit. It allows the user to access the unit via
the web interface. (Factory Default: 172.16.70.1 )
Control Port Subnet Mask:
is the Subnet Mask address of the unit. It allows the user to access the unit from
another network via the web interface. (Factory Default: 255.255.255.0 )
Control Port Default Gateway:
is the gateway address of unit. It allows the user to access the unit from another
network via the web interface. (Factory Default: 172.16.70.254 )
EAS Port IP Address:
Is the static IP address assigned to the IP EAS Port. (Factory Default: 192.168.252.2 )
EAS Port Subnet Mask:
is the subnet mask address of the IP EAS port. (Factory Default: 255.255.255.0 )
EAS Port Default Gateway:
Is the gateway address of the IP EAS Port. (Factory Default: 192.168.252.254 )
GigE Port IP Address:
is the static IP address assigned to the Gigabit Ethernet (GigE) port. (Factory Default: 192.168.253.1 )
GigE Port Subnet Mask:
is the subnet mask address of the GigE port. (Factory Default: 255.255.255.0 )
GigE Port Default Gateway:
Is the gateway address of the GigE Port. (Factory Default: 192.168.253.254 )
Event Log Destination:
is the IP address of the remote server, to which Syslog sends the activities recorded by the
unit for monitoring and troubleshooting purposes. (Factory Default: 172.16.70.2 )
Log Destination Port #:
is the Error Log Destination port to which a duplicate of the error messages created by the
unit can be forwarded for monitoring and troubleshooting purposes.
(Factory Default: 514 - unmodifiable)
Time Server IP:
is the IP address for the Time Server from where the unit can obtain its clock reference. See Section
6.1.2 for details. (Factory Default: 172.16.70.2 )
Syslog Errors:
is to enable/disable forwarding error messages (in red font) to a Syslog.
(Factory Default: Disabled)
Syslog Informational:
is to enable/disable the unit to forward information messages (in blue font) to a Syslog.
(Factory
Default: Disabled)
Syslog Feedback:
is to enable/disable the unit to forward feedback or confirmation messages (in green font) to a
Syslog. (Factory Default: Disabled)
Average Bit Rate:
The factory default for this option is "Disabled". The
“Enabled” setting should only be used when
incorrect bitrate information is specified in the video header as received from the broadcaster. Incorrect declared
bitrates from the broadcaster may cause overload/ buffer issues affecting the output TS. The “Enabled” setting allows
the unit to assign an alternate bitrate instead of what’s declared in the input TS.
Once Average Bit Rate is set to "Enabled", go to in section 6.3 (p.22) , and follow the instructions in order to
complete enabling of this feature.