Output QAM Mode:
Allows the user to select the desired QAM modulation mode. Options are: 64B, 256B, 16A,
32A, 64A, 128A, and 256A. For most applications in the USA, the recommended QAM modulation mode is 256B.
Output QAM Data Rate:
Indicates the standard baud rate depending on the selected QAM mode, for example
5.360500 Mbaud for QAM 256B.
Output QAM Interleaver:
Indicates the interleaver value for the selected QAM mode.
Output QAM Alpha:
Indicates the Alpha value for the selected QAM mode.
QAM Lock State:
indicates whether Quad-QAM module is working properly (locked) or not.
NOTE:
The modules may take a few seconds to lock when QAM output parameters are changed.
5
6
6.8 "Main > EAS" Screen
The “Main > EAS” screen (Figure 6.8, next page) is an EAS feature enabling all input program streams to be replaced by the
input present on the ASI or IP input. This web page allows the user select between ASI and IP. For IP, the user also enters
the address, port and protocol. Commands are available for manual test of the EAS mode. This tab is only displayed when
the output mode (see Section 6.6) is active.
The TS requirements for the EAS input are as follows:
(1) The ASI input should be a single program input with (PMT[O]). If multiple programs are present in the EAS TS
input,then program #1 (PMT(O) or first PMT) will be selected for EAS override. The other programs will be ignored.
(2) If ASI input #1 thru #11 have multiple audios, then only the first Audio service is overridden with EAS Audio.
The front panel ASI Input LEDs will be flashing green when EAS is activated.
Upon removing the trigger mechanism the unit will return to its normal operation.
When EAS source = IP
Shows the IP information and software version of the unit.
EAS IP address:
user must enter EAS stream source IP address and port.
EAS IP protocol, options are
RTP and UDP.
EAS source selection is
IP or ASI .
For IP use RJ-45 connection on rear of unit.
For ASI use BNC connector on rear of
unit.
EAS Stream info:
Provides stream information for EAS.
EAS Override:
overrides the external EAS Trigger and releases the forced trigger for testing purposes.
Remember
to
click
on
the
SAVE
button
to
apply
the
new
values/configurations.