Installation
8
Plumbing Connections
WATER CONNECTION
NOTE: Hot water maximizes steam production
but is not required. Cold water may be
supplied to both inlets if hot water is not
available.
Connect cold water hose to the cold water (left) soĆ
lenoid and hot water to the hot water (right) soleĆ
noid. Use pressure hose with 3/4" (1.9 cm) fittings
and wall shut off valves for service.
NOTE: Hot water must not be applied to the cold
water inlet.
1/2" Appliance Hose
With 3/4" Hose Fittings
Figure 2
WARNING!!
The use of poor quality water will invaliĆ
date your warranty.
This product must be installed by a licensed
Plumber or Gas Fitter when installed within the
Commonwealth of Massachusetts.
DRAIN CONNECTION
A 2" (5 cm) copper pipe with standard drain pitch
must be run to an open drain or connected to a
standpipe equipped with a vent.
NOTE: The waste water can also be directed to a
nearby floor drain. Flexible hose which alĆ
lows trapped water to accumulate in
sagged runs must be avoided.
1. Find the drain connection on the lower rear of
the unit.
2. Loosen the coupling clamps. Attach a 2" (5
cm) copper drain pipe to the drain connection.
Retighten the coupling clamps.
NOTE: The open end of the drain should be inĆ
stalled facing the floor. Copper line, used
for installation to an open drain or floor
sink, must be supplied by the installer.
Use
of a trap inline will cause drain backup.
2" Drain
Customer
Supplied
To Drain
Oven
Drain
Figure 3