![Blaze King TORINO II 1606 Скачать руководство пользователя страница 38](http://html.mh-extra.com/html/blaze-king/torino-ii-1606/torino-ii-1606_operation-and-installation-manual_2772333038.webp)
OM-1606 E V1.03
April 2, 2014
Page 38
TORINO II Freestanding 1606
TO BE DONE BY QUALIFIED PERSONNEL ONLY
1. Disconnect the gas and electricity to the appliance.
2. Remove pedestal front cover and rear cover (4 screws) including fan (fi g. 20c).
3. Undo the gas lines (one in, two out and pilot).
4. Disconnect all electrical connections to valve including ground wire
5. Valve is attached to valve bracket with 4 screws, 2 at the back (see fi g. 20d) and two at the side, loosen all
of them.
6. Installation is the reverse order of the previous steps.
NOTE: WHEN INSTALLING NEW VALVE, CHECK IF ANY UNUSED PORTS ARE PLUGGED.
CHECK OUTLET PRESSURE (3.5” W.C.) AND CHECK FOR LEAKS
See “INTERMITTENT PILOT & VALVE” on page 23 for detailed gas valve image.