OM-1606 E V1.03
April 2, 2014
Page 35
TORINO II Freestanding 1606
FUEL CONVERSION
WARNING:
This conversion kit shall be installed by a qualifi ed service agency in accordance with the manufacturer’s
instructions and all applicable codes and requirements of the authority having jurisdiction. If the information
in these instructions is not followed exactly, a fi re, explosion or production of carbon monoxide may result
causing property damage, personal injury or loss of life. The qualifi ed service agency is responsible for the
proper installation of this kit. The installation is not proper and complete until the operation of the converted
appliance is checked as specifi ed in the manufacturer’s instructions supplied with the kit.
CONVERSION KIT CONTENTS
Th
is conversion kit contains the following parts:
1. Z0712 (LPG)> # 53 and LPG Stepper motor kit.
2. Z0714 (NG)> # 38 and NG Stepper motor kit.
3. Conversion Kit labels.
To convert from NG to LPG or reverse, follow the next steps:
1. Replace
orifi ces, see “BURNER TRAY REMOVAL AND INSTALLATION” on page 37 for Burner tray
removal & installation.
2. Replace stepper motor (see next page).
3. Convert pilot fuel (see instructions below).
How to convert Pilot fuel:
1. Use a 7/16” wrench to loosen the pilot hood.
2. Push the little tab in and the little tab with hole should pop out. Th
e hole stamp tab (LP) out is used for
Propane. Th
e stamped tab (NA) out is for Natural Gas.
3. Re-tighten the pilot hood.
Fill out the fuel conversion label on the appliance (inside side doors)
See “ASSEMBLY INSTRUCTIONS cont.” on page 10 for proper pilot and burner fl ame pictorials.
All valves have been pre-set and certifi ed for installation at elevations from 0 – 4500 feet (1 – 1372m) above sea
level.
HIGH ELEVATIONS
When installing this unit at higher elevations, it is necessary to decrease the input rating by replacing the existing
burner orifi ce with a smaller size for installations over 4500 feet (1370 m). Th
e appliances input should be
reduced 4% for each additional 1000 feet (305 m) above sea level. For the USA, de-rate the unit from sea level
according to the gas installation code.
Altitude
NG
LPG
0 – 4,500 ft (0 – 1372 m)
36
52
4,500 – 6,500 ft (1372 – 1981 m)
38
53
Содержание TORINO II 1606
Страница 7: ...OM 1606 E V1 03 April 2 2014 Page 7 TORINO II Freestanding 1606 APPLIANCE DIMENSIONS ...
Страница 26: ...OM 1606 E V1 03 April 2 2014 Page 26 TORINO II Freestanding 1606 LIGHTING INSTRUCTIONS ...
Страница 36: ...OM 1606 E V1 03 April 2 2014 Page 36 TORINO II Freestanding 1606 FUEL CONVERSION cont ...
Страница 44: ...OM 1606 E V1 03 April 2 2014 Page 44 TORINO II Freestanding 1606 REPLACEMENT PARTS cont ...
Страница 49: ...OM 1606 E V1 03 April 2 2014 Page 49 TORINO II Freestanding 1606 NOTES ...