OM-1606 E V1.03
April 2, 2014
Page 16
TORINO II Freestanding 1606
INSTALLATION INSTRUCTIONS cont.
VENTING
Th
is appliance will not function without being connected to a proper venting system. Th
is unit can be used with
Selkirk (Direct-Temp), American Metal, Security Chimneys or Simpson Duravent 4” x 6-5/8” venting. Read
the manufacturer’s installation instructions before installing the venting system.
Typical Installation
- 24”(min) vertical vent pipe on top of the appliance,
- One 90° elbow, and up to 24” (max) horizontal run to the outside (with a 2’ vertical rise).
Other installations
• Up to 4 - 90° elbows, or equivalent, maximum.
• Minimum 2’ (610mm) straight length between bends.
• Th
e total vertical height up to 30’ (9.14 m) maximum.
• Use vent restrictor over 20’ vertical height .
• Th
e total horizontal run up to 16’ (4.88m) maximum.
• Note: 2’ (0.6m) minimum of vertical height required.
NOTE: Maximum vent lengths may be subject to local codes.
For best venting performance, here are some general venting rules:
1. Use only vent systems and components certifi ed for use with this appliance.
2. Maintain a minimum of 1” (26 mm) clearance to combustibles from the outside surfaces of vertical vents
and minimum of 1” (26 mm) sides and bottom, and 2” (51 mm) from top surfaces of horizontal vents.
Always use a wall thimble when passing through combustible construction.
3. Observe all local code restrictions, if any, regarding the installation of this type of gas appliance.
4. Observe the vent height and length restrictions given in this manual.
5. Never slope horizontal vents downwards.
6. Maintain at least an upward slope of 1/4” (7 mm) for every 1 ft (305 mm) of horizontal vent.
7. Terminate the vent with a termination certifi ed for use with this appliance.
8. Support horizontal vent every 3 ft (915 mm) to prevent it from sagging.
Содержание TORINO II 1606
Страница 7: ...OM 1606 E V1 03 April 2 2014 Page 7 TORINO II Freestanding 1606 APPLIANCE DIMENSIONS ...
Страница 26: ...OM 1606 E V1 03 April 2 2014 Page 26 TORINO II Freestanding 1606 LIGHTING INSTRUCTIONS ...
Страница 36: ...OM 1606 E V1 03 April 2 2014 Page 36 TORINO II Freestanding 1606 FUEL CONVERSION cont ...
Страница 44: ...OM 1606 E V1 03 April 2 2014 Page 44 TORINO II Freestanding 1606 REPLACEMENT PARTS cont ...
Страница 49: ...OM 1606 E V1 03 April 2 2014 Page 49 TORINO II Freestanding 1606 NOTES ...