OM-1606 E V1.03
April 2, 2014
Page 6
TORINO II Freestanding 1606
GENERAL INFORMATION cont.
INSTALLATION CODES
Th
is appliance must be installed by a qualifi ed gas appliance installer. Th
is appliance is certifi ed for installation
in a bedroom or a bedsitting room. Th
is appliance is only for use with the type of gas indicated on the rating
plate and may be installed in an aft ermarket, permanently located, manufactured (mobile) home where not
prohibited by local codes. Th
is appliance is not convertible for use with other gases, unless a certifi ed kit is
used. Only for direct discharge without duct connection. Th
is appliance must be direct vented using listed and
approved Simpson Dura-Vent, Selkirk, Security or American Metal Products vent components.
SPECIFICATIONS
MODEL Torino II
Natural Gas (NG)
Propane (LPG)
Manifold Pressure
3.5 in. w.c. (0.87kPa)
11.0 in. w.c. (2.74 kPa)
Min. Supply Pressure for
Purpose of Input Adjustment
7 in. w.c. (1.74 kPa)
11.0 in. w.c. (2.74 kPa)
Orifi ce Size
DMS # 36
DMS # 52
Nominal Input Rating
30,500 BTU/hr
30,500 BTU/hr
Minimum Input Rating
20,600 BTU/hr
17,200 BTU/hr
Altitude
0 - 4,500 ft. (0 - 1372 m)
0 - 4,500 ft. (0 - 1372 m)
Primary Air Opening
50% (Minimum)
open
Electrical Rating
120 V.A.C. System
120 V.A.C. System
HIGH ALTITUDE INSTALLATION
When installing this appliance beyond 4500 ft . (1372 m) above sea level, the appliance must be properly de-rated
and installed according to local codes, in the absence of local codes, with the current National Fuel Gas Code,
ANSI Z223.1/ NFPA 54, in the US or Installation Code, CSA-B149.1, in Canada.
CAUTION
• Due to high temperatures, the appliance should be located out of traffi c and
away from furniture and draperies.
• Children and adults should be alerted to the hazards of high surface temperature
and stay away to avoid burns or clothing ignition.
• Young children should be carefully supervised when they are in the same room
as the appliance.
• Clothing or other fl ammable material should not be placed on or near the
appliance.
• Installation and repair should be done by a qualifi ed service person. The
Appliance should be inspected before use and at least annually by a
professional service person. More frequent cleaning may be required due to
excessive lint from carpeting, bedding material, etcetera. It is imperative that
control compartments, burners and circulating air passageways of the appliance
be kept clean.
Содержание TORINO II 1606
Страница 7: ...OM 1606 E V1 03 April 2 2014 Page 7 TORINO II Freestanding 1606 APPLIANCE DIMENSIONS ...
Страница 26: ...OM 1606 E V1 03 April 2 2014 Page 26 TORINO II Freestanding 1606 LIGHTING INSTRUCTIONS ...
Страница 36: ...OM 1606 E V1 03 April 2 2014 Page 36 TORINO II Freestanding 1606 FUEL CONVERSION cont ...
Страница 44: ...OM 1606 E V1 03 April 2 2014 Page 44 TORINO II Freestanding 1606 REPLACEMENT PARTS cont ...
Страница 49: ...OM 1606 E V1 03 April 2 2014 Page 49 TORINO II Freestanding 1606 NOTES ...