background image

180-CL29-SP v1.00

March 12, 2019

Page 16

Clarity CL29 SP

 MAINTENANCE and SERVICE

GLASS DOOR REMOVAL

For installation, cleaning, and burner removal the 
glass door must be removed.

1.  Turn off  the appliance and allow it to cool 

down completely.

2.  There are tabs on the safety screen trim 

that fi t into slots on the appliance.  Lift the 
safety screen trim up and out, away from 
the appliance, and set it aside.   (

Fig.3

)

3.  There are two door latch mechanisms on 

top of the glass door.(

Fig.4

)  Pull the tabs 

forward and up off  the door tabs.

4.  Carefully slide the door glass assembly up 

and out of the unit and set it aside.(

Fig.5

)

Fig.3

Fig.4

Fig.5

Содержание Clarity CL29.IPI

Страница 1: ...erious injury death or property damage Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Leave the premises Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructi...

Страница 2: ...____________________ 13 OPERATING INSTRUCTIONS ____________________________________________________________ 14 PILOT LIGHT 14 LIGHTING THE BURNER 14 OPTIONAL BLOWER 14 MAINTENANCE and SERVICE____________________________________________________________ 15 ROUTINE MAINTENANCE 15 CLEANING SURFACES 15 CLEANING THE GLASS 15 GLASS DOOR REMOVAL 16 GLASS DOOR REPLACEMENT 17 BURNER REMOVAL 17 SAFETY SCREEN...

Страница 3: ..._____________________________________________________________________ 39 NOTES ___________________________________________________________________________________ 44 REQUIRED KIT choose one S Z4918 SHROUD CL29 26 5 x 38 S Z4924 SHROUD CL29 32 x 44 TRIMMABLE S Z4932 SHROUD CL29 29 x 40 S Z4933 SHROUD CL29 32 x 44 S Z4973 SHROUD CL29 23 x 37 OPTIONAL KITS S 0402 FIREBOX GLASS KIT 3PC CL29 S 0602 FIR...

Страница 4: ...duals in the house To restrict access to a fireplace or stove install an adjustable safety gate to keep toddlers young children and other at risk individuals out of the room and away from hot surfaces Any safety screen guard or barrier removed for servicing an appliance must be replaced prior to operating the appliance Clothing or other flammable materials should not be placed on or near the applian...

Страница 5: ... envelope Never vent to another room or inside the building Make sure the specified vent pipe is used properly sized and of adequate height to provide sufficient draft The flow of combustion and ventilation air must not be obstructed The appliance and its appliance main gas valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in exce...

Страница 6: ...his appliance is certified for installation in a bedroom or a bedsitting room This appliance is only for use with the type of gas indicated on the rating plate and may be installed in an aftermarket permanently located manufactured mobile home where not prohibited by local codes This appliance is not convertible for use with other gases unless a certified kit is used Only for direct discharge withou...

Страница 7: ...with air filters SN 30 170 0244 indd Cet appareil doit être installé selon les codes locaux s il y en a sinon suivez l actuel ANSI Z223 1 NFPA 54 ou Gaz Naturel et Propane Codes CSA B149 1 MISE EN GARDE Une mauvaise installation un ajustement une altération service ou entretien peuvent causer des blessures ou des dommages à la propriété Consultez le manuel du propriétaire fourni avec cet appareil P...

Страница 8: ... at a minimum height of eight 8 feet above grade directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in size GAS VENT DIRECTLY BELOW KEEP CLEAR OF ALL OBSTRUCTIONS 4 INSPECTION The state or local gas inspector of the side wall horizontally vented gas fueled equipment s...

Страница 9: ...HILE MAY CAUSE TEMPORARY CONDENSATION TO APPEAR ON THE GLASS THIS IS A NORMAL OCCURRENCE AS YOUR APPLIANCE HEATS UP DIMENSIONS RATING LABEL LOCATION The rating label is located below the firebox behind a flip down door It is affixed to rectangular metal sheets that are chained to the appliance FLUE EXHAUST AIR INTAKE ...

Страница 10: ...80 CL29 SP v1 00 March 12 2019 Page 10 Clarity CL29 SP SHROUD AND SHELF OPTIONS S Z4918 SHROUD CL29 26 5 x 38 S Z4924 SHROUD CL29 32 x 44 TRIMMABLE S Z4932 SHROUD CL29 29 x 40 S Z4933 SHROUD CL29 32 x 44 ...

Страница 11: ...F OPTIONS S Z4973 SHROUD CL29 23 x 37 S Z4966 ASH SHELF CL29 44 REQUIRES CL29 SHROUD S Z4954 ASH SHELF RISER CL29 ONE OR TWO RISERS CAN BE USED REQUIRES CL29 SHROUD AND ASH SHELF S Z4964 CL29 4 SIDED SHROUD BOTTOM REQUIRES S Z4918 CL29 SHROUD 26 5 OR S Z4973 SHROUD 23 x 37 ...

Страница 12: ...g the hinged panel that is below the firebox 4 Set the manual burner switch to the OFF position 5 Push in gas control knob slightly and turn clockwise to OFF 6 Wait five 5 minutes to clear out any gas Then smell for gas including near the floor If you smell gas STOP Follow B in the safety information above If you don t smell gas go to the next step 7 Turn control knob counterclockwise to PILOT positi...

Страница 13: ...Manual HI LO adjustment or pressure regulator adjustment 3 Pilot adjustment 4 Thermocouple connection 5 Mounting for piezo bracket 6 Inlet pressure test point 7 Outlet pressure test point 8 Main operator 9 Pilot outlet 10 Main gas outlet 11 Flange mounting screw holes 12 Additional valve mounting holes 13 Alternative TC connection point 14 Thermoelectric unit 15 Inlet ...

Страница 14: ...e optional blower OFF for the first two to three hours This will cure all the paint gasket and seals It is advised to open a door or window as the unit will smoke and give off odors as it is curing OPTIONAL BLOWER An optional blower S Z4946 SP is available For installation refer to the installation instructions provided with the kit Turn the blower on by turning the Blower Speed knob clockwise Fig 2...

Страница 15: ...NING SURFACES Painted powder coated or porcelain enameled surfaces should be wiped with a damp cloth periodically Ensure the appliance has cooled down completely before any cleaning Do not use other cleaners as they may leave a residue which can become permanently etched into the surface CLEANING THE GLASS DO NOT TO CLEAN THE GLASS WHILE IT IS HOT One of the by products of combustion and moisture ...

Страница 16: ...t to cool down completely 2 There are tabs on the safety screen trim that fit into slots on the appliance Lift the safety screen trim up and out away from the appliance and set it aside Fig 3 3 There are two door latch mechanisms on top of the glass door Fig 4 Pull the tabs forward and up off the door tabs 4 Carefully slide the door glass assembly up and out of the unit and set it aside Fig 5 Fig 3 ...

Страница 17: ...ss from the door must be done by a qualified service technician The glass door must be purchased from a Blaze King dealer No substitute materials are allowed BURNER REMOVAL 1 Turn off the appliance and allow it to cool down completely 2 Remove the safety screen trim and glass door see GLASS DOOR REMOVAL on previous page 3 Remove the floor plate and set it aside Fig 6 4 Remove the screw from the left ...

Страница 18: ...305 for Z4921 Safety Screen Trim 1 Turn off the appliance and allow it to cool down completely 2 Remove the safety screen trim by lifting up and out see GLASS DOOR REMOVAL 3 Slide the safety screen out of the frame the tabs may have to be adjusted Fig 8 4 Slide the new safety screen in between the frame face and the tabs Ensure screen mesh faces out furthest from glass see image below 5 Hang the sa...

Страница 19: ...o convert from NG to LPG or reverse 1 Turn off the appliance and allow it to cool down completely 2 Remove burner see BURNER REMOVAL 3 Replace main orifice 4 Convert pilot fuel see below 5 Replace regulator see next page 6 Check and properly adjust gas manifold as well as verity the input rate of the appliance upon completion of conversion How to convert CLARITY CL29 SP Pilot orifice 1 Use a 7 16 wre...

Страница 20: ...52 021 001 Turn control knob to the OFF position and shut off the gas supply to the valve Using a Torx T20 or slotted screwdriver remove and discard the three pressure regulator mounting screws A pressure regulator tower B and the spring and diaphragm assembly C Ensure the rubber gasket D which is prefitted as part of assembly E is properly positioned and install the new HI LO pressure regulator a...

Страница 21: ...anual shutoff ball valve The inlet has a 1 2 female pipe thread SHUT OFF VALVE LOCATION Use present location of shut off valve if the fireplace size provides adequate clearance or if size is restricted move the shut off valve underneath firebox THE APPLIANCE AND ITS INDIVIDUAL SHUTOFF VALVE MUST BE DISCONNECTED FROM THE GAS SUPPLY PIPING SYSTEM DURING ANY PRESSURE TESTING OF THAT SYSTEM AT TEST PRESSUR...

Страница 22: ...Chimney cleanouts must fit properly Check local codes whether a continuous length is required or if certified joiner kits may be used Minimum 8 ft Maximum 36 ft Flashing Co linear DV vertical termination cap Air Intake Exhaust Flue FACTORY BUILT FIREPLACE OR ZERO CLEARANCE FIREPLACE Ensure that there is a minimum base of sheet metal below the unit upon installation along with supplied levelling bolt...

Страница 23: ...PLACE DIMENSIONS The minimum fireplace dimensions the this insert are in the following diagrams and chart MINIMUM CLEARANCES TO COMBUSTIBLES A Unit to sidewall 4 5 115 mm B Bottom of unit to underside of mantle With S Z4974 mantle shield 52 1321 mm 42 1067 mm C Maximum mantle depth 12 305 mm D Minimum ceiling clearance from bottom of unit 67 5 1715 mm NOTE CHECK LOCAL CODES FOR FLOOR REQUIREMENTS T...

Страница 24: ...installment by removing the back blower access cover If the appliance is already installed go to step 5 3 Affix the blower to the access cover as shown the blower edge should be against the cover flange 4 Feed blower wires and assembly through opening and reattach the access cover 5 Feed the power cord wires through the case hole 6 Slide the loomex bushing into the case hole 7 Rotate the loomex bushi...

Страница 25: ...d washer from the rheostat 10 Affix the rheostat to control panel in same orientation as shown in picture below note alignment pin 11 Attach star washer nut and knob to rheostat post 12 Connect the black W wire from the rheostat to the white W wire from the power cord 13 Fasten the ground from the power cord to the case as shown below ...

Страница 26: ...e back of the case keep wires from getting pinched or snagged 15 Slide the snapdisk into the clip on the left hand side of the firebox bottom panel 16 Connect the black B wire from the blower to the black B wire from the power cord 17 Fasten the control panel back onto the case 18 See ELECTRICAL REQUIREMENTS for wiring diagram ...

Страница 27: ...n trim aside 3 REMOVE THE STATIC CLING LABEL THAT IS ON THE DOOR GLASS Hold glass to frame when removing as it is only held in place with silicone Set the door glass assembly aside 4 If installing the optional S 0402 FIREBOX GLASS KIT 3 piece or the S 0602 FIREBOX GLASS KIT 4 piece then refer to their respective installation instructions 5 If installing the optional S 0519 LOG SET DRIFT CLARITY 5P...

Страница 28: ...utside horizontal cap with a minimum 8 vertical pipe Clearances are in accordance with local installation codes and the requirements of the gas supplier Other installations The total vertical height up to 36 10 97 m maximum Use vent restrictor on vents from 20 6 09 m to 36 10 97 m to obtain optimal flame appearance see VENT RESTRICTOR and BURNER FLAME APPEARANCE NOTE Maximum vent lengths may be sub...

Страница 29: ...nd tie off if necessary Ensure the flex vent is stretched as needed 2 Unscrew the 1 4 20 bolt from the vent connector slide plate Fig 14 remove the vent connector slide plate and attach it to the flex vent as shown below 3 Adjust the flex vent until the vent connector is at the same height as the insert 4 Slide the insert into place guide the vent connector slide plate into the guides on the top of th...

Страница 30: ...ssary it can be adjusted as follows 1 Turn off the appliance and allow it to cool down completely 2 Remove the safety screen trim and glass door set aside see GLASS DOOR REMOVAL 3 Move the restrictor tab off of the restrictor index plate Fig 17 4 Adjust the restrictor index plate to one of the slots to obtain desired flame and reset the restrictor tab into the restrictor index plate slot 5 Reinstall ...

Страница 31: ...e air shutter should be closed slightly until the correct flames are achieved Slide the air shutter to the right to reduce the amount of air 5 Flames that are very orange with tall dark stringy tips are not getting enough air Therefore the air shutter should be opened slightly until the desired flames are achieved Slide the air shutter to the left to increase the amount of air 6 Tighten air shutter ...

Страница 32: ... 6 63 1 7 5 7 63 127 0 6SDGH RQQHFWRUV 6XSSOLHG ZLWK DQV ELECTRICAL REQUIREMENTS ELECTRICAL GROUNDING INSTRUCTIONS THIS APPLIANCE IS EQUIPPED WITH A GROUND SCREW FOR YOUR PROTECTION AGAINST SHOCK HAZARD ENSURE PROPER GROUNDED WIRING IS SUPPLIED AND CONNECTED TO THIS UNIT LABEL ALL WIRES PRIOR TO DISCONNECTION WHEN SERVICING CONTROLS WIRING ERRORS CAN CAUSE IMPROPER AND DANGEROUS OPERATION VERIFY P...

Страница 33: ...orizontal Termination Cap aluminum 46DVA HC Square Horizontal Termination Cap stainless steel 46DVA HC S Square Horizontal Termination Cap copper 46DVA HC C Horizontal Square Termination Cap 984 ICC PARTS LIST DESCRIPTION PART CO LINEAR ALUMINUM FLEX KITS Standard 3 x3 Co linear Flex Kit Includes TM IVT TF MFR two 35 lengths of 3 diameter 2 ply AL flex TM ALK33 Traditional 3 x3 Co linear Flex Kit I...

Страница 34: ... INSULATED KIT 35 X 2 W BLACK CAP INSERT CO LINEAR TERMINATION CAPS 940033 3 X 3 VCL PRO FORM TERM CAP 940033B 3 X 3 VCL PRO FORM TERM CAP BLACK 940033C 3 X 3 VCL PRO FORM TERM CAP COPPER BDM PARTS LIST cont ORDER DESCRIPTION VERTICAL CO LINEAR TEMINATION CAPS W SS BASE 9400330808SS 3 X3 VCL PRO FORM TERM CAP W 8X8 SS BASE 9400330808SSB 3 X3 VCL PRO FORM TERM CAP W 8X8 SS BASE BLACK 9400330808SSC ...

Страница 35: ...Galvanized and Powder Coated Black VDV VCCH33 3 x3 High Wind Co Linear Cap VDV HC04 Horizontal Cap VDV VCH04 Vertical Termination Cap VDV VCC33 Vertical Round High Wind VDV CC33 Vertical Square Cap VDV CTT04 3 Co linear to Coax Adapter VDV CAC04 4 Co linear Appliance Adapter SELKIRK PARTS LIST PRODUCT NUMBER PART DESCRIPTION 4 x 6 5 8 ADAPTERS 1604245B 4DT AA Appliance Adapter Black 4 x 6 5 8 TERM...

Страница 36: ...tions to valve including ground wire 7 Remove the screw securing the air shutter lever to the valve tray Fig 20 8 Remove the fifteen screws securing the valve tray to the firebox Fig 20 Pull the valve assembly up and out of the firebox Note the washer on the air shutter lever 9 Remove the four screws holding the valve and valve bracket to the firebox bottom and remove the valve 10 Installation is the ...

Страница 37: ...URNER 4 610 0712 PILOT ASM ADJ NG LPG PSE 5 Z4917 CL29 DOOR ASSEMBLY 6 645 1630 SAFETY SCREEN 16 X 30 5 7 S Z4921 SAFETY SCREEN TRIM w SCREEN 8 600 SIT 013 EXTENSION KNOB HI LO 1 5 9 600 SIT 012 EXTENSION KNOB ON OFF 1 5 10 600 SIT 010 VALVE M_V_NOVA NG 3 5 1 6 11 Z4914 VALVE ASM WITH BURNER 12 600 SIT 011 PIEZO WITH NUT 13 145 0725 SWITCH ON OFF LARGE ...

Страница 38: ...rmocouple circuit Check for proper connection of the thermocouple to the rear of the valve If loose fully tighten Check pilot for full flame impingement around thermocouple If flame is too small check gas pressure adjust pilot rate screw check pilot head for damage Check thermocouple voltage at valve It must be greater than 5 mV If low replace thermocouple Air in gas line pilot dies while knob is de...

Страница 39: ...lacement parts Warranty Period Components Covered Parts Labor Gas 1 Year X All parts materials and surface finishes flaking and peeling Except as covered by Conditions Exclusion and Limitations listed 2 Years X Igniters Thermocouple Thermopile Molded Refractory Panels Log sets Fan assembly Ignition components Gas valve Burner components Thermostat 5 Years 2 Years X Firebox Heat Exchanger 10 Years 2 ...

Страница 40: ...ce finishes against defects in materials and workmanship for part repair or replacement and limited labor for the first 1 year to the original purchaser Please see the exclusions and limitations section below as certain restrictions and exclusions apply to this warranty How the Warranty Works Includes Conditions Exclusions and Limitations 1 All warranties by the manufacturer are set herein and no cl...

Страница 41: ...ons 10 The Limited Warranty does not cover installation and operational related problems such as use of downdrafts or spillage caused by environmental conditions Environmental conditions include but are not limited to nearby trees buildings roof tops wind hills mountains inadequate venting or ventilation excessive offsets negative air pressures or other influences caused by mechanical systems such a...

Страница 42: ...k the customer will pay any in home travel fees or service charges required by the Authorized Dealer 27 At no time will Blaze King be liable for any consequential damages which exceed the purchase price of the unit Blaze King has no obligation to enhance or modify any stove once manufactured example as a stove model evolves field modifications or upgrades will not be performed 28 This Limited Warran...

Страница 43: ...180 CL29 SP v1 00 March 12 2019 Page 43 Clarity CL29 SP NOTES ...

Страница 44: ...180 CL29 SP v1 00 March 12 2019 Page 44 Clarity CL29 SP NOTES ...

Отзывы: