180-CL26.SP.1 v1.00
July 30, 2020
Page 6
CL26.SP.1
CERTIFICATION LABEL
Model: CL26 top vent appliance
Modèle: CL26 appareil de ventilation vers le haut
o
NATURAL GAS
o
LP GAS
Orifice (DMS) 0-1370 m
39
1.5 mm
Input rating / Puissance d’entrée (BTU/hr / Kw ) 0-1370m 0-4,500 ft Alt.
Minimum Input / Entrée Minimum (BTU/hr / Kw)
Manifold Pressure High setting / Manifold Pression réglé à High (In w.c. / kPa)
Manifold Pressure Low setting / Manifold Pression réglé à Low (In w.c. / kPa)
Minimum Inlet Pressure / Pression minimum d'admission (In w.c. / kPa)
27,300 / 8.00
14.838 / 4.35
3.8 / 0.95
1.0 / 0.25
7.0 / 1.74
26,200 / 7.68
14,120 / 4.14
10.6 / 2.64
2.9 /0.72
11.0 / 2.74
This appliance must be installed in accordance with local codes, if any; if none, follow the National Fuel Gas Code, ANSI Z223.1 / NFPA 54, or the Natural
Gas and Propane Installation Code, CSA B149.1.
WARNING: Improper installation, adjustment, alteration, service, or maintenance can cause injury or property damage Refer to the owner's manual
provided with this appliance. For assistance or additional information consult a qualified installer, service agency, or the gas supplier.
Hot while in operation. Do not touch. Keep children, clothing, furniture, gasoline and other liquids having flammable vapors away. Keep burner and
control compartment clean. See installation and operating instructions accompanying appliance.
VENTED GAS FIREPLACE HEATER —NOT FOR USE WITH SOLID FUEL
For use with glass doors certified with the appliance only. Do not operate this appliance with glass removed, cracked or broken. Replacement of the
panel(s) should only be done by a qualified person. For use only with barrier Part No. 645.1821. Part No. S.Z5177.SP or S.Z5177.IPI Fan Kit may be used.
Also for use in OEM / mobile(manufactured) homes after home is on site. Convertible for use with natural gas or propane as follows: For natural gas
when equipped with orifice #39; For propane when equipped with orifice 1.5 mm. May be installed in a bedroom or sitting room when installed with a
listed thermostat control in Canada.
Cet appareil doit être installé selon les codes locaux, s’il y en a: sinon suivez l’actuel ANSI Z223.1 / NFPA 54 ou Gaz Naturel et Propane Codes, CSA
B149.1.
MISE EN GARDE: Une mauvaise installation, un ajustement, une altération, service ou entretien peuvent causer des blessures ou des dommages à la
propriété. Consultez le manuel du propriétaire fourni avec cet appareil. Pour assistance ou information additionnelle, consultez un installateur qualifié,
agence de service ou votre fournisseur de gaz.
Chaud lorsque l’appareil fonctionne. Ne pas toucher. Tenir loin des enfants, vêtements, meubles, essence et autres liquides ayant des vapeurs
inflammables. Tenir le compartiment du brûleur et de contrôle propre. Voir les instructions de l’installation et du fonctionnement accompagnant cet
appareil.
FOYER AU GAZ AVEC ÉVENT —NE PAS UTILISER AVEC DU COMBUSTIBLE SOLIDE
Utiliser seulement avec des portes vitrées certifiées pour cet appareil. Ne pas opérer cet appareil, si la vitre est manquante, craquée, ou brisée. Le
remplacement des panneaux de verre seulement être fait par une personne qualifiée. À utiliser uniquement avec le numéro de pièce de barrière
645.1821. Numéro de pièce fan S.Z5177.SP ou S.Z5177.IPI ou Ensemble Ventilateur peuvent être utilisés. Aussi pour l'usage dans les maisons mobiles
(manufacturées) après que la maison soit installée sur le site. Pouvant être converti pour usage avec le gaz naturel ou le propane comme suit: Pour le
gaz naturel une fois équipé d'un orifice # 39.; Pour le propane une fois équipé de l'orifice # 1.5 mm. Peut être installé dans une chambre à coucher ou un
salon une fois installé avec un thermostat approuvé au Canada.
MINIMUM CLEARANCES TO COMBUSTIBLES /
DÉGAGEMENTS MINIMUM REQUIS ENTRE L’APPAREIL ET DES MATÉRIAUX
COMBUSTIBLES
A
Unit to sidewall / Unité au mur latéral
2” (51 mm)
B Unit to back wall / Unité à au mur arrière
2.5” (64 mm)
C
Unit corner to sidewall / Unité en coin au mur
2” (51 mm)
D Unit to top / Unité jusqu’au haut
33” (838 mm )
E Alcove width / alcôve largeur
27.875" (708 mm)
F Alcove height / alcôve hauteur
70.5" (1791 mm)
G
Vent / évacuation de surface exterieure
1" (25 mm) from outside surface*
NOTE: CHECK LOCAL CODES FOR FLOOR REQUIREMENTS. THIS FIREPLACE IS SUITABLE FOR INSTALLATION ON A COMBUSTIBLE SURFACE.
VÉRIFIER LES CODES LOCAUX POUR ÉQUIPEMENT DE SURFACE DE PLANCHER, CET APPAREIL PEUT ÊTRE INSTALLÉ SUR UNE SURFACE COMBUSTIBLE
* 2" (51 mm) horizontal vent to combustible
Electrical Rating: 115 Volts, 0.7 Amp, 60 Hz for CL26.IPI and S.Z5177.SP Fan Kit.
DANGER: Risk of electrical shock. Disconnect power before servicing unit. Do not route power cord beneath heater. This appliance must be installed
in accordance with the Standard CAN/CSA Z240 MH, Mobile Housing, in Canada, or with the Manufactured Home Construction and Safety Standard, Title
24CFR, Part 3280, in the United States, or when such a standard is not applicable, ANSI / NCSBCSA 225.1 / NFPA501A, Manufactured Home Installations
Standard. This appliance is only for use with the type of gas indicated on the rating plate and may be installed in an aftermarket, permanently located,
manufactured(mobile) home where not prohibited by local codes. See owners manual for details. This appliance is not convertible for use with other
gases unless a certified kit is used. This vented gas fireplace is not for use with air filters.
Caractéristiques électriques: 115 Volts, 0.7 Amp, 60 Hz pour CL26.IPI et S.Z5177.SP Ensemble Ventilateur.
DANGER: Risque d’électrocution. Débrancher le courant avant de réparer l’unité. Ne pas mettre le cordon d’alimentation en dessous de l’appareil de
chauffage. Cet appareil doit être installé selon les codes CAN/CSA Z240 MH, maisons mobiles (manufacturées), au Canada, sinon applicable, utilisez ANSI
/ NCSBCS A225.1/NFPA 501 A, Installation d’une maison mobile standard.
Cet appareil peut être utilisé seulement avec le type de gaz indiqué sur la plaque de contrôle et peut être installé dans un marché des accessoires, maison
(mobile) de manière permanente placée et manufacturée où ils ne sont pas interdit par des codes. Voir le manuel d’installation pour des détails. Cet
appareil ne peut pas être converti pour l'usage avec d'autres gaz à moins qu'un kit de conversion certifié soit employé. Ce foyer au gaz à évacuation ne
pas être utilisé avec des filtres à air.
MANUFACTURE DATE
JAN
o
FEB
o
MAR
o
APR
o
MAY
o
JUN
o
JUL
o
AUG
o
SEP
o
OCT
o
NOV
o
DEC
o
2020
o
2021
o
2022
o
2023
o
2024
o
2025
o
170-0249 [06 20]
MANUFACTURED IN:
o
USA:
Blaze King Industries
146A Street, Walla Walla, WA. 99362
o
CANADA:
Valley Comfort Systems
1290 Commercial Way, Penticton, B.C. V2A 3H5
CSA P.4.1-15 Fireplace Efficiency (FE) / Efficacité énergetique des foyer (EEF) CSA P.4.1-15:
CL26.IPI Natural Gas / Gaz naturel: 65.00%, Propane Gas / Gaz Propane: 61.00%
CL26.SP Natural Gas / Gaz naturel: 64.49%, Propane Gas / Gaz Propane: 59.41%
CL26.SP
o
CL26.IPI
o
Listed vented gas fireplace heater / Poêle certifié au gaz avec évacuation
MODEL / MODÈLE
: CL26 top venting appliance / CL26 appareil ventilé vers le haut
This stove is factory equipped for 0-1372 m (0-4500 ft) / Ce poêle est manufacturé et équipé pour 0-1372 m (0-4500 pied)
UNITED STATES AND CANADA / ÉTATS-UNIS ET LE CANADA: Certified to: CSA 2.17-2017, ANSI Z21.88-2017/CSA 2.33-2017
Certifié: CSA 2.17-2017, ANSI Z21.88-2017/CSA 2.33-2017
PFS report#F19-558
SN - 35.