www.blaubergventilatoren.de
Freshbox 100 WiFi
5
The unit is designed for indoor application with the ambient temperature ranging from +1 °C up to +40 °C and relative humidity up to
80 %. The unit is rated as a Class I electrical appliance.
Hazardous parts access and water ingress protection rating:
• IP44 for the unit motors
• IP 22 for the assembled unit connected to the air ducts
The unit design is constantly being improved, thus some models may be slightly different from those described in this manual.
Parameter
Freshbox 100 WiFi
Freshbox E-100 WiFi
Freshbox E1-100 WiFi
Freshbox E2-100 WiFi
Maximum air capacity [m
3
/h]
30
44
60
75
100
30
44
60
75
100 30
44
60
75 100 30
44
60
75 100
Supply voltage [V/50 (60) Hz]
1~ 110-240
1~ 220-240
1~ 220-240
1~ 220-240
Maximum fan power [W]
20
23
29
37
53
20 23
29
37
53
20 23
29
37
53
20 23
29
37
53
Sound pressure level at 3 m distance [dBA]
13
20
27
33
39
13
20
27
33
39
13
20
27
33
39
13
20
27
33
39
Electric heater power [W]
preheating
-
600
-
600
reheating
-
-
350
350
Maximum unit current [A]
without an electric
heater
0.4
0.4
0.4
0.4
with an electric
heater
-
3.08
1.94
4.67
Transported air temperature [°С]
from -25 up to +50
Casing material
painted steel
Insulation
foam rubber, 10 mm
Heat recovery efficiency [%]
96
94
92
89
87
96
94
92
89
87
96
94
92
89
87
96
94
92
89
87
Heat exchanger type
counter-flow
Heat exchanger material
polystyrene
Supply filter
G4, F8 (option: F8 Carbon,
H13)
G4, F8 (option: F8 Carbon,
H13)
G4
G4
Extract filter
G4
Connected air duct diameter [mm]
Ø 100
Weight [kg]
31
31
31
31
Parameter
Freshbox 100 ERV
WiFi
Freshbox E-100 ERV
WiFi
Freshbox E1-100 ERV
WiFi
Freshbox E2-100 ERV
WiFi
Maximum air capacity [m
3
/h]
30
44
60
75
100
30
44
60
75
100
30
44
60
75
100
30
44
60
75
100
Supply voltage [V/50 (60) Hz]
1~ 110-240
1~ 220-240
1~ 220-240
1~ 220-240
Maximum fan power [W]
20 23
29
37
53
20
23
29
37
53
20 23
29
37
53
20
23
29
37
53
Sound pressure level at 3 m distance [dBA]
13
20
27
33
39
13
20
27
33
39
13
20
27
33
39
13
20
27
33
39
Electric heater power [W]
preheating
-
600
-
600
reheating
-
-
350
350
Maximum unit current [A]
without an electric
heater
0.4
0.4
0.4
0.4
with an electric
heater
-
3.08
1.94
4.67
Transported air temperature [°С]
from -25 up to +50
Casing material
painted steel
Insulation
foam rubber, 10 mm
Heat recovery efficiency [%]
96
94
92
89
87
96
94
92
89
87
96
94
92
89
87
96
94
92
89
87
Heat exchanger type
counter-flow
Heat exchanger material
enthalpy membrane
Supply filter
G4, F8 (option: F8 Carbon,
H13)
G4, F8 (option: F8 Carbon,
H13)
G4
G4
Extract filter
G4
Connected air duct diameter [mm]
Ø 100
Weight [kg]
31
31
31
31
TECHNICAL DATA