30
Obstructed or ripped
dusthose.
Check the tension of the
blower/fan V-belt.
Check and replace if
necessary.
Adjust the tension of the V-
belt.
Motor failure warning light
is lit
The motor protection
switch was triggered, for
example: caused by wrong
power supply or defective
equipment.
Check the power supply for
the correct voltage and
Hertz.
Call for a skilled electrician to
check the motor protection
switch inside the electrobox.
Phase sequence warning
light is lit
The phases of the power
supply are connected
wrong.
Call for a skilled electrician to
change the phase inversion
switch inside the electrobox.
Note: If a motor protection switch has been triggered by overload, it can be switched on again
after a short cooling down period.
Old equipment contains valuable materials which are valuable for re-processing.
The machine parts must
not be thrown
away in the normal household waste,
but should be disposed of at a suitable proper
collection system, e. g. via your communal disposal location. This way the materials can be re-used in an
environmentally responsible manner.
Despite the fact that this guide is made with care, Blastrac takes no liability for errors in the manual and the possible
consequences. We are naturally very interested in your findings and additions. No part of this publication may be reproduced