![Blastrac 2-48DC Скачать руководство пользователя страница 15](http://html1.mh-extra.com/html/blastrac/2-48dc/2-48dc_operating-instructions-manual_2769643015.webp)
15
5.2
Starting / stopping the machine
Make sure both silencers on top of the machines are closed
before every startup!
Starting up with opened silencers can cause start-up failures and
could cause excessive wear of
the v-belts.
Connect the dust hoses to the machine.
Connect the dust collector to the power supply.
Check the warning lights, if a warning light is lit, see 5.5 Startup
Problems for guidance.
Switch on the compressor motor (1).
Switch on the rotating valve motor (4).
Switch on the fan motors (2) wait for the fans to get at full
speed.
Open the silencers on top of the machine.
Carry out this actions in opposite sequence to stop the machine.
5.3
Work with the machine
Be sure that rotating valve motor is switched on and the compressor pulses at the correct pressure.
This will increase the life-time of the filter cartridges.
Regularly check the contents of the big bag, exchanging the big bag too late can cause a big mess and
be potential dangerous to the health.
Regularly use the air pistol to remove water from the air tank.
Excessive water can have a negative impact on the pulse power and shortens the life-time of the filter
cartridges.
The suction power of the dust collector can be adjusted with the air flow pressure regulators on the
silencer. Slide the hoods open for more power, and close them for less power.
5.4
Interrupting work
This machine is built to work with continuously, leave the 2-48DC running during short interruptions.
When temporarily interrupting the work (1/2 hour
–
1 hour), turn off the fan unit only and close the
silencers. Pulse cleaning of the filter system will continue and will increase the life-time of the filter
cartridges.
During a longer stand still of the dust collector, first switch off the fan unit. Let the pulse cleaning cycle
run for +/- 5 minutes. Switch off the compressor unit and rotating valves.
Disconnect the power-supply cable.
Close the sliding covers of the silencers when the machine is turned off. This prevents moisture, dust
and other contaminants to enter the machine.
Prevent unauthorized persons from getting access to the dust collector or take measurements to
prevent unauthorized working with the equipment.
5.5
Startup Problems
I
f the light ‘Failure’
(6) is lit up, a fault has been detected and the system has shut down.
If the light ‘Phase Incorrect’
(5) is lit up, the phases of the power connection are wrong. Correct this by
changing the phase inverter inside the main power plug.
If the light ‘Control Voltage’
(7) is not lit up, the machine has no power supply.
1
2
3
4
5
6
7
8