background image

18

Shotblasting Problems & Possible Solutions

Problem:

Breaker is tripping when BP-9-1 10V and dust collector are turned to the ON position.

Possible Solution:

BP-9-1 10V and dust collector should be powered by separate breakers. Find

electric outlets with separate breaker switches and use accordingly. Check circuit breaker sizes.

Problem:

BP-9-1 10V is vibrating excessively.

Possible Solution:

Check blast wheel immediately. Excessive vibration is usually caused by the

blast wheel being out of balance due to it being worn or by blades being broken or chipped.
Install new blast wheel kit. Failure to install new wheel kit in this instance could lead to serious
damage to machine.

Problem:

BP-9-1 10V is creating excessive noise.

Possible Solution:

This problem is most likely caused by an improper alignment of the blast

wheel and control cage. Check alignment of blast wheel and control cage immediately and
verify that there is adequate clearance between the blast wheel and the control cage.

Problem:

BP-9-1 10V is creating excessive wear on liners and blast housing.

Possible Solution:

Adjust control cage so that the "hot spot" is centered in work area rather than

on liners or housing.

Problem:

BP-9-1 10V is dropping an excessive amount of steel shot.

Possible Solution:

Verify "hot spot" is centered properly and adjust control cage as necessary.

Verify seals do not have excessive wear, feed spout is aligned properly, and shot valve is closing
when shot lever is released. Verify dust collector has adequate suction.

Problem:

The blasting performance of the BP-9-1 10V has diminished.

Possible Solution:

Verify that there is an adequate amount of steel shot in the shot hopper and

that shot is free of concrete dust or other contaminants. Verify there are no obstructions in the
shot valve or feed spout and the feed spout is properly aligned. Verify that the shot valve is
opening properly. Verify that the blast wheel and the control cage are not excessively worn.
Verify dust collector has adequate suction.

Problem:

BPS-110V is difficult to push or gets stuck in areas.

Possible Solution:

Verify that the seals are positioned properly and that they are not too close to

the floor. Raise height of seals.

Содержание BP-9-110v

Страница 1: ...STARTUP 6 SAFETY OPERATION PROCEDURES 7 SAFETY SHUT DOWN PROCEDURES 8 SAFETY MAINTENANCE PROCEDURES 9 CHECK LIST 10 OPERATING INSTRUCTIONS 11 SETTING THEBLASTPATTERN 11 TRANSPORTATION 13 WEAR PARTS 14...

Страница 2: ...VIDUALS RESPONSIBLE FOR OPERATION MAINTENANCE OR SERVICE OF THE EQUIPMENT The individuals responsible for operating maintaining and servicing the equipment should thoroughly understand and follow all...

Страница 3: ...ast wheel at a very high rate of speed which causes the shot to be thrown through an opening in the control cage and down onto to the concrete surface that is being cleaned Due to the high rate of spe...

Страница 4: ...ations relating to the use of portable tools on construction sites These statutory requirements standards and regulations are posted on the OSHA website at www osha g ov The operator and maintenance p...

Страница 5: ...ds dust masks ear plugs hard hats steel toed work boots long sleeved shirts tight fitting clothing and gloves It is also imperative for staff to tie back long hair and to remove all jewelry Work area...

Страница 6: ...all screws and other fasteners are tight Check the shot storage hopper the feed spout and the blast wheel parts for foreign bodies and remove them if present Check the blast wheel blades control cage...

Страница 7: ...tioning and to eliminate possible damage to electrical components Safety Operation Procedures When operating the BP 9 1 10V perform the following safety procedures SUPPORT PERSONNEL MUST KEEP A SAFE D...

Страница 8: ...tting down the BP 9 1 10V always perform the following safety procedures Shut off the shot supply by pushing the shot valve handle down Advance the machine until you are sure that no deep holes are be...

Страница 9: ...y a licensed electrician When performing electrical servicing work make certain that all replacement electrical components comply with the original parts and are correctly adjusted All other repairs m...

Страница 10: ...e switch on the BP 9 1 10V and the dust collector to the ON position for two minutes so as to verify that the circuit breaker will not trip 10 Disconnect the hose from the BP 9 1 10V to verify that th...

Страница 11: ...trial and error The importance of selecting the proper blast pattern cannot be overemphasized An improper or unevenly distributed blast pattern results in excessive blasting on either the right or le...

Страница 12: ...n The hot spot should be in the center of the width blasted The hot spot can be altered by rotating the control cage Rotating the control cage in a counter clockwise direction will move the hot spot t...

Страница 13: ...excessive force or of using incorrect loading and unloading procedures Before transportation the BP 9 1 10V should be separated into machine filter unit and general accessories Note Personnel must rem...

Страница 14: ...Shot Hopper 30 hours Warping or thin spots Feed Spout 50 hours Thin spots Blast Wheel 10 hours Blades deteriorated 50 Control Cage 10 hours Deteriorated edges Blast Wheel Hub 10 hours Missing pins de...

Страница 15: ...trol cage assembly 10 Remove the arbor nut and the blast wheel 11 Check the wheel hub for wear and replace when necessary 12 Install the new blast wheel and the arbor nut 13 Reattach the control cage...

Страница 16: ...16 BP 9 110V Drawing...

Страница 17: ...rol Cage Bracket BT976324 9 Control Cage BT451476 1 0 F e e d S p o u t Included with Item 12 1 1 F e e d S p o u t H o s e Included with Item 12 1 2 S h o t V a l v e BTP000001 1 3 S i d e B r u s h...

Страница 18: ...m BP 9 1 10V is creating excessive wear on liners and blast housing Possible Solution Adjust control cage so that the hot spot is centered in work area rather than on liners or housing Problem BP 9 1...

Страница 19: ...en make additional passes over the floor surface Problem BP 9 1 10V or dust collector is emitting concrete dust Possible Solution Verify there are no holes in the duct hose leading from the BPS 110V t...

Отзывы: