Switch 3 - Sample Rate Conversion, No Sample
Rate Conversion
Set switch 3 to OFF to enable sample rate conversion, or
ON to disable sample rate conversion. This switch should
almost always be set to OFF to ensure audio is embedded
at the correct sample rate for television.
When switch 3 is set to OFF this setting converts the sample
rate of your analog or AES/EBU audio and embeds audio
into the SDI output at a sample rate of 48 kHz.
Switch 2 - Ch 2 or AES/EBU 3+4 Embed / Bypass
Once you have selected your audio channels, use switches
2 and 1 to select which channels to embed or disable. The
disable setting lets you avoid overwriting audio channels
you wish to keep in the audio signal.
Set switch 2 to ON to bypass channel 2, or AES/EBU
channels 3 and 4. Set switch 1 to ON to bypass channel 1,
or AES/EBU channels 1 and 2.
Switch 1 - Ch 1 or AES/EBU 1+2 Embed/Bypass
See switch 2 description.
The switch legend on the base of your converter gives you
all the information you need to change conversion settings.
Audio Selection Tables
Input Audio Source
Switch 8
Switch 7
Switch Diagram
XLR Analog
OFF
OFF
XLR AES/EBU
OFF
ON
Rca Analog
ON
OFF
Optical
ON
ON
SDI Channel Tables
Analog Audio Channels
Switch 6
Switch 5
Switch 4
Switch Diagram
1-2
OFF
OFF
OFF
3-4
OFF
OFF
ON
5-6
OFF
ON
OFF
7-8
OFF
ON
ON
9-10
ON
OFF
OFF
Содержание Teranex Mini HDMI to SDI 12G
Страница 2: ...Teranex Mini Converters English 3 36 Fran ais 70 Deutsch 104 Espa ol 138 172 206 240 Italiano 274...
Страница 36: ...Manuel d utilisation et d installation Teranex Mini Converters Septembre 2015 Fran ais...
Страница 70: ...Installations und Bedienungsanleitung Teranex Mini Converters Deutsch September 2015...
Страница 104: ...Manual de instalaci n y funcionamiento Conversores Teranex Mini septiembre de 2015 Espa ol...
Страница 138: ...Manuale di istruzioni I convertitori Teranex Mini settembre 2015 Italiano...