CHAPTER 3: INSTALLATION
29
To install the rack mounting bracket:
1.
Remove the two side screws closest to the front from each side of your Octet
switch.
2.
Line up the holes in the brackets with the holes on the sides of the Octet switch.
3.
Using the screws supplied with the rack mounting bracket, thread one through each
of the holes in the sides of the rack mount brackets and into the Octet switch. Tighten
them securely.
4.
Install the Octet switch into your rack using the approved method of your rack
manufacturer.
To install a new single Octet switch:
1.
Plug the supplied power cord into the back of the Octet switch and then into an
appropriate power source.
2.
Connect a terminal or PC running terminal emulation software (such as
HyperTerminal
®
) to the terminal port of the Octet switch using the supplied null
modem cable. The terminal should be set to 9600 baud, 8 bits, 1 stop bit, no parity
and no flow control.
3.
When the power is switched on, the Power indicator on the front of the unit will
remain orange for approximately 30 seconds while performing a self-test and then
change to green. This indicates a healthy condition.
4.
Next, follow these instructions to set up the Terminal Applications menu. Refer to
Chapter 6 for more details.
a.
You will be prompted to enter a username. The first time you access the switch,
enter the username
admin
and press
Enter
. Once you have access to the Octet
switch Console menu, you can configure a password should you wish to do so.
b.
Once you have logged in to the Octet switch, you will see the Octet switch
Console menu with four options. Select option 1,
Network Configuration
. This
will activate the Network Configuration menu.
c.
Within the Network Configuration menu, select option 1 to set the IP address.
d.
Select options 2 and 3 to set your netmask and default gateway respectively.
e.
Once these settings are entered, type
0
to return to the Octet switch
Console menu.
f.
If all Octet switches in your installation are part of the same Octet switching system
configuration, you may leave the configuration ID set to
00000
. If you are running
more than one Octet switching system configuration within your subnet, you will
need to designate the group to which this Octet switch belongs. To do this, select
option 2 to enter the configuration ID for your Octet switch. A configuration ID will
designate an Octet switch as part of a unique installation. When change commands
are issued through the Octoware software, only units with the same configuration ID
as the Octoware software will be affected. Refer to
System Management
in Chapter
6 for more information on setting configuration IDs.
g.
Once you have entered a configuration ID, enter
0
to return to the main menu.
h.
Finally, select option 3 and follow the prompts to password protect your Octet
switching system terminal settings.
i.
Press
0
to exit the Octet switching system Console menu.
Содержание ServSwitch Octet KV1700
Страница 1: ...DECEMBER 2005 KV1700 KV1701 KV1702 KV1703 KV1711 KV1712 KV1713...
Страница 2: ......
Страница 8: ...SERVSWITCHTM OCTET INSTALLER USER GUIDE 6...
Страница 10: ...SERVSWITCHTM OCTET INSTALLER USER GUIDE 8...
Страница 20: ...SERVSWITCHTM OCTET INSTALLER USER GUIDE 18...
Страница 52: ...SERVSWITCHTM OCTET INSTALLER USER GUIDE 50...
Страница 66: ...SERVSWITCHTM OCTET INSTALLER USER GUIDE 64...
Страница 74: ...SERVSWITCHTM OCTET INSTALLER USER GUIDE 72...
Страница 79: ......