5V
4.0A
12
1
16
1
OPTIONS
COMPUT
Remote switching control
The port switching functions of the ServSwitch CX Quad
IP unit can be remotely controlled by an RS232 link to the
OPTIONS
port on the rear panel.
The sending device must use the following RS232
communication settings:
Baud rate: 19200 bps
Data bits:
8
Parity:
None
Stop bits:
1
No handshaking is implemented, however, valid command characters will be
echoed back to the sending device.
Note: You must ensure that the ServSwitch CX Quad IP
unit has it Options serial
ports set to ‘Sync Units’. This setting (together with the baud rate selection) can
be made either via the
or
user configuration menus.
The value of the byte received via the serial link determines which computer port
should be linked through to the user port. The table given here summarizes the
valid control codes:
REMOTE
CONTROL
®
724-746-5500
®
0
0
Local user
10
11
12
13
14
15
16
17
18
19
1A
1B
1C 1D
1E
1F
71
VNC user
20
21
22
23
24
25
26
27
28
29
2A
2B
2C 2D
2E
2F
72
VNC user
30
31
32
33
34
35
36
37
38
39
3A
3B
3C 3D
3E
3F
73
VNC user
40
41
42
43
44
45
46
47
48
49
4A
4B
4C 4D
4E
4F
74
VNC user
50
51
52
53
54
55
56
57
58
59
5A
5B
5C 5D
5E
5F
75
Host computer port/channel
(video off)
Cable from serial
control device
ServSwitch CX Quad IP
rear panel