CHAPTER 5: Configuration
Figure 5-3. Flow-control jumper settings.
RTS CTS
No jumpers installed =
No hardware flow
control
Two jumpers installed
vertically on lower
pairs of posts =
DTR/DSR flow control
across the CAT5 link
Two jumpers installed
vertically on lower
pairs of posts and
another horizontally
across top posts =
DTR/DSR flow control
across the CAT5 link,
RTS/CTS looped back
(typical setting for
serial printers and
touchscreens)
Two jumpers installed
vertically on upper
pairs of posts =
RTS/CTS flow control
across the CAT5 link
Two jumpers installed
vertically on upper
pairs of posts and
another horizontally
across bottom posts =
RTS/CTS flow control
across the CAT5 link,
DTR/DSR looped back
Two jumpers installed
horizontally across top
and bottom posts =
Both RTS/CTS and
DTR/DSR looped back
(factory-default
setting)
DTR DSR
RTS CTS
DTR DSR
RTS CTS
DTR DSR
RTS CTS
DTR DSR
RTS CTS
DTR DSR
RTS CTS
DTR DSR