About Features and Configuration
The Managed Media Converter built-in features include the following:
•
AutoCross
•
Broadcast Storm Protection
The Managed Media Converter configurable features include the following:
•
Securely separates the SNMP management network from the data network
•
IEEE 802.1Q VLAN Tagging
•
Q-in-Q VLAN Extra-Tagging with Ethertype (TDIP) selection
•
Remote traffic monitoring
•
Remote automatic alarms
•
Bandwidth limiting
•
FiberAlert (loss return) for Fiber versions only
•
FX and TX LinkLoss (loss pass through)
•
Loopback testing
•
Autonegotiation
•
Selective Advertising
These features are software configurable from the serial port craft connection, a Telnet
session, iConfig, iView
2
, or from the DHCP client. The serial craft port connection and the
Telnet session provide the best line setup and initialization configuration tools. iConfig and
iView
2
provide the best monitoring, management, and maintenance tools.
Hardware Configuration
Before installing the module in a chassis, there are two features that must be selected using
DIP switches. These feature selections include the following:
•
Enable/Disable management on each port
(DIP switches 1, 2, and 3)
•
Configure the module to be either a Standalone, a Host, or a Remote
(DIP switches 7 and 8)
49
5.
Enter up to 32 VLAN IDs in the Data VLANs rows. VLAN IDs can range from 1 to
4094.
Data Vlans <Optics <----> Data>
VLAN 1 [0 ] [
101
] VLAN 12 [0 ] [
112
] VLAN 23 [0 ] [
123
]
VLAN 2 [0 ] [
102
] VLAN 13 [0 ] [
113
] VLAN 24 [0 ] [
124
]
VLAN 3 [0 ] [
103
] VLAN 14 [0 ] [
114
] VLAN 25 [0 ] [
125
]
VLAN 4 [0 ] [
104
] VLAN 15 [0 ] [
115
] VLAN 26 [0 ] [
126
]
VLAN 5 [0 ] [
105
] VLAN 16 [0 ] [
116
] VLAN 27 [0 ] [
127
]
VLAN 6 [0 ] [
106
] VLAN 17 [0 ] [
117
] VLAN 28 [0 ] [
128
]
VLAN 7 [0 ] [
107
] VLAN 18 [0 ] [
118
] VLAN 29 [0 ] [
129
]
VLAN 8 [0 ] [
108
] VLAN 19 [0 ] [
119
] VLAN 30 [0 ] [
130
]
VLAN 9 [0 ] [
109
] VLAN 20 [0 ] [
120
] VLAN 31 [0 ] [
131
]
VLAN 10 [0 ] [
110
] VLAN 21 [0 ] [
121
] VLAN 32 [0 ] [
132
]
VLAN 11 [0 ] [
111
] VLAN 22 [0 ] [
122
]
6.
Press
S
or
F3
to save the settings.
7.
Type
reboot
.
Now the Managed Media Converter is configured to pass only packets with tags containing
the VLAN IDs defined in the Data VLANs table. VLAN ID numbers defined in this table
must not be the same as the number used for the Management VLAN ID.
ON
S1
1 2 3 4 5 6 7 8 9 0
EXT MGMT port management
DIP switch (1) is set to ON (default).
DATA:
Up to 32
VLAN IDs
OPTICS:
Up to 32
VLAN IDs