4

 

About Features and Configuration 

The Managed Media Converter built-in features include the following: 

 

AutoCross 

 

Broadcast Storm Protection 

The Managed Media Converter configurable features include the following: 

 

Securely separates the SNMP management network from the data network 

 

IEEE 802.1Q VLAN Tagging 

 

Q-in-Q VLAN Extra-Tagging with Ethertype (TDIP) selection 

 

Remote traffic monitoring 

 

Remote automatic alarms 

 

Bandwidth limiting 

 

FiberAlert (loss return) for Fiber versions only 

 

FX and TX LinkLoss (loss pass through) 

 

Loopback testing 

 

Autonegotiation 

 

Selective Advertising 

These features are software configurable from the serial port craft connection, a Telnet 
session, iConfig, iView

2

, or from the DHCP client.  The serial craft port connection and the 

Telnet session provide the best line setup and initialization configuration tools.  iConfig and 

iView

2

 provide the best monitoring, management, and maintenance tools. 

Hardware Configuration 

Before installing the module in a chassis, there are two features that must be selected using 

DIP switches.  These feature selections include the following: 

 

Enable/Disable management on each port  
(DIP switches 1, 2, and 3) 

 

Configure the module to be either a Standalone, a Host, or a Remote 
(DIP switches 7 and 8) 

 

49

 

5.

 

Enter up to 32 VLAN IDs in the Data VLANs rows.  VLAN IDs can range from 1 to 
4094. 

Data Vlans  <Optics <----> Data> 
VLAN  1 [0   ]   [

101

 ]  VLAN 12 [0   ]   [

112

 ]   VLAN 23 [0   ]   [

123

 ] 

VLAN  2 [0   ]   [

102

 ]  VLAN 13 [0   ]   [

113

 ]   VLAN 24 [0   ]   [

124

 ] 

VLAN  3 [0   ]   [

103

 ]  VLAN 14 [0   ]   [

114

 ]   VLAN 25 [0   ]   [

125

 ] 

VLAN  4 [0   ]   [

104

 ]  VLAN 15 [0   ]   [

115

 ]   VLAN 26 [0   ]   [

126

 ] 

VLAN  5 [0   ]   [

105

 ]  VLAN 16 [0   ]   [

116

 ]   VLAN 27 [0   ]   [

127

 ] 

VLAN  6 [0   ]   [

106

 ]  VLAN 17 [0   ]   [

117

 ]   VLAN 28 [0   ]   [

128

 ] 

VLAN  7 [0   ]   [

107

 ]  VLAN 18 [0   ]   [

118

 ]   VLAN 29 [0   ]   [

129

 ] 

VLAN  8 [0   ]   [

108

 ]  VLAN 19 [0   ]   [

119

 ]   VLAN 30 [0   ]   [

130

 ] 

VLAN  9 [0   ]   [

109

 ]  VLAN 20 [0   ]   [

120

 ]   VLAN 31 [0   ]   [

131

 ] 

VLAN 10 [0   ]   [

110

 ]  VLAN 21 [0   ]   [

121

 ]   VLAN 32 [0   ]   [

132

 ] 

VLAN 11 [0   ]   [

111

 ]  VLAN 22 [0   ]   [

122

 ] 

6.

 

Press 

S

 or 

F3

 to save the settings. 

7.

 

Type 

reboot

Now the Managed Media Converter is configured to pass only packets with tags containing 

the VLAN IDs defined in the Data VLANs table.  VLAN ID numbers defined in this table 
must not be the same as the number used for the Management VLAN ID.

 

ON

S1

1 2 3 4 5 6 7 8 9 0

 

EXT MGMT port management  

DIP switch (1) is set to ON (default). 

DATA:
Up to 32 
VLAN IDs 

OPTICS:
Up to 32 
VLAN IDs 

Содержание LMC543C

Страница 1: ...tside U S call 724 746 5500 FREE technical support 24 hours a day 7 days a week Call 724 746 5500 or fax 724 746 0746 Mail order Black Box Corporation 1000 Park Drive Lawrence PA 15055 1018 Web site w...

Страница 2: ...ception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one of the following measures Reorient or relocate the receiving antenn...

Страница 3: ...nnection 2 Management Software 2 About Dynamic Host Control Protocol DHCP 3 About Features and Configuration 4 Hardware Configuration 4 Installation Instructions 6 Assigning IP Information 7 Software...

Страница 4: ...0 km Requires SFP I55 Extended Diagnostic Module NOTE Single strand versions SS display the transmit frequency in the Media 2 column 53 Safety Certifications UL CUL Listed to Safety of Information Tec...

Страница 5: ...g with EtherType TPID selection Remote monitoring and automatic alarms Bandwidth limiting The Host Remote pair configuration provides the following features Extends any 10 100 Mbps Ethernet based VLAN...

Страница 6: ...t and is accessed by using the included RJ 45 to DB 9 adapter The serial connection provides access the Managed Media Converter module configuration screens these configuration screens are also access...

Страница 7: ...nits in Host Remote applications and then reconfiguring all of the settings 3 iConfig Utility iConfig is a configuration utility in iView that lets you quickly and easily complete the first stages of...

Страница 8: ...must be selected using DIP switches These feature selections include the following Enable Disable management on each port DIP switches 1 2 and 3 Configure the module to be either a Standalone a Host o...

Страница 9: ...traffic passes between Optics and Data port EXCEPT what has been defined as the Management Domain The Management Domain can either be defined as untagged traffic or traffic with a specified VLAN ID I...

Страница 10: ...ve screw The Managed Media Converter module includes on board SNMP logic When installed in an iMediaChassis manage the Managed Media Converter module from the chassis by using the Unified Management A...

Страница 11: ...tall a 100 Mbps speed SFP Many SFPs including those from Black Box feature enhanced diagnostics capabilities with a Digital Diagnostics Monitoring Interface DDMI DDMI statistics provide real time acce...

Страница 12: ...UPLINK port except for the device s management traffic When in Loopback mode the Managed Media Converter module stops the OPTICS or UPLINK port traffic from continuing on out of the DATA port Address...

Страница 13: ...0 VLAN 32 0 0 VLAN 11 0 0 VLAN 22 0 0 Valid Vlan IDs are between 1 and 4094 Valid priorities are between 0 and 7 Type S or F3 to save the changes Type Q or F4 to quit and cancel changes Transparent Mo...

Страница 14: ...lect the TPID for the Extra Tag 1 8100 2 9100 3 9200 Extra Tag TPID 1 8100 5 On the Host Managed Media Converter module enter Y in the Are Extra Tags left on the Data Port field to only accept the Ext...

Страница 15: ...ort N Select the TPID for the Extra Tag 1 8100 2 9100 3 9200 Extra Tag TPID 1 8100 TRANSPARENT MODE SETUP Is a VLAN tag required on Management packets Y Do you want to enter the Extra Tag mode Enter Y...

Страница 16: ...N ID 7 as management g Type reboot Now the Managed Media Converter is configured to pass all data between the OPTICS or UPLINK and DATA ports except that which is tagged with VLAN ID 7 All data tagged...

Страница 17: ...Tag is 7 Management Priority is 0 e Make sure the Are VLAN Tags required on the EXT Port field is set to N TRANSPARENT MODE SETUP Is a VLAN tag required on Management packets Y Do you want to enter th...

Страница 18: ...TE 39 Now the Managed Media Converter is configured to pass only tagged data between the OPTICS or UPLINK and DATA ports All untagged data is considered management traffic and passes from the OPTICS o...

Страница 19: ...passes between Optics and Data port EXCEPT what has been defined as the Management Domain The Management Domain can either be defined as untagged traffic or traffic with a specified VLAN ID In Transpa...

Страница 20: ...air 2 TX LinkLoss detects the fault and disables the OPTICS or UPLINK port 3 FX LinkLoss detects the fiber loss and disables the DATA port The link fault is passed through the media conversion and is...

Страница 21: ...can also be performed using a Telnet session You can only use one Telnet session at a time There are three levels of Telnet account access User View status change own password and reboot Operator User...

Страница 22: ...connected device Press Enter after each You can also assign a default gateway to allow the unit to be visible beyond the local network press Enter to skip When finished press Enter then type reboot f...

Страница 23: ...e a new community string go to the main configuration screen and press C Enter the name of the new community up to 16 characters no spaces and press Enter Then type one of the following to assign the...

Страница 24: ...you can launch a console session through the serial port and type in the command cleandb If both the serial and the iConfig passwords are forgotten you must contact technical support Ending Your Sess...

Страница 25: ...two levels of cleandb The first level resets the Telnet iConfig password and all of the SNMP database values The second level additionally resets the IP address IP Subnet Gateway VLAN settings CLI com...

Страница 26: ...FXLinkLoss Only Enabled TXLinkLoss Only Enabled FiberAlert Plus FXLinkLoss Enabled FiberAlert Plus TXLinkLoss Enabled TXLinkLoss Plus FXLinkLoss Enabled TXLinkLoss FXLinkLoss FiberAlert Enabled Fiber...

Страница 27: ...trol Settings Unit FlowControl Disable FlowControl Globally Unit FiberAlert TXLinkLoss Plus FXLinkLoss Enabled Unit LoopBack No LoopBack Normal Traffic Mode Unit Max FrameSz Oversized Frames 1536 802...

Страница 28: ...management isolation and is not recommended for normal use This section describes the telnet serial port screens and fields available for configuring the Managed Media Converter modes 29 In the above...

Страница 29: ...0 0 VLAN 25 0 0 VLAN 4 0 0 VLAN 15 0 0 VLAN 26 0 0 VLAN 5 0 0 VLAN 16 0 0 VLAN 27 0 0 VLAN 6 0 0 VLAN 17 0 0 VLAN 28 0 0 VLAN 7 0 0 VLAN 18 0 0 VLAN 29 0 0 VLAN 8 0 0 VLAN 19 0 0 VLAN 30 0 0 VLAN 9 0...

Страница 30: ...a Tagging Enter N if you do not want Extra Tags N Are VLAN Tags required on the EXT Port N Type S or F3 to save the new information Type Q of F4 to quit and cancel changes Reboot is required for any c...

Отзывы: