The Managed Media Converter module includes the following port configurations: 

 

Fixed-port configuration: 

 

10/100 Mbps RJ45 data port (DATA) 

 

100 Mbps ST or SC fiber port (OPTICS), or 10/100 Mbps RJ-45 copper port (UPLINK 

port on the all-RJ45 port version) 

 

10/100 Mbps RJ-45/Serial port (EXT MGMT) for isolating management traffic and for 

connecting a serial cable. 

 

Small Form-Factor Pluggable (SFP) configuration: 

 

10/100 Mbps SFP or RJ-45 data port (DATA) 

 

100 Mbps SFP port (OPTICS) 

 

10/100 Mbps RJ-45/Serial port (EXT MGMT) for isolating management traffic and for 

connecting a serial cable 

All RJ-45 ports auto-negotiate or can be manually set to 10 Mbps or 100 Mbps, and Half or 
Full Duplex.  Fiber ports operate at 100 Mbps and auto-negotiate Full-Duplex. 

Managed Media Converter modules include LinkLoss and FiberAlert for troubleshooting, 
loopback testing functionality, and protection against Broadcast Storms.   

You can easily configure the Managed Media Converter by using either the serial port craft 
connection or the management software. 

Serial Craft Port Connection 

A serial craft port connection to the module is included on the Managed Media Converter 
module.  This port is located on the RJ-45 EXT MGMT port and is accessed by using the 
included RJ-45 to DB-9 adapter.  The serial connection provides access the Managed Media 
Converter module configuration screens (these configuration screens are also accessible from a 
Telnet connection). 

Management Software 

iView² is the management software designed specifically for the family of managed modules.  It 
features a graphical user interface (GUI) and gives network managers the ability to monitor 

and control the intelligent products (designated with the “i” prefix). 

iView

2

 is available in several versions and can also function as a snap-in module for HP 

OpenView

TM

 Network Node Manager.  Refer to the iView² Chassis online help for more 

information regarding configuring and managing the Managed Media Converter module. 

 

51

 

 

Make sure READ/WRITE Community Strings for Managed Media Converter and iView² 
are the same. 

 

Make sure that none of the twisted pair ports on the Managed Media Converter are 
connected to the twisted pair port on the iMediaCenter chassis or the management 
module in an iMediaChassis series chassis. 

 

SNMP

SNMP

Management

Module

 

Black Box Customer Service 

Order toll-free in the U.S.:

 Call 877-877-BBOX  

(outside U.S. call 724-746-5500) 

Free technical support

, 24 hours a day, 7 days a week. 

Call:

 724-746-5500 or 

Fax:

 724-746-0746 

Mail order:

 Black Box Corporation 

1000 Park Drive, Lawrence, PA 15055-1018 

Web site:

 

www.blackbox.com

  

E-mail:

 [email protected] 

Содержание LMC543C

Страница 1: ...tside U S call 724 746 5500 FREE technical support 24 hours a day 7 days a week Call 724 746 5500 or fax 724 746 0746 Mail order Black Box Corporation 1000 Park Drive Lawrence PA 15055 1018 Web site w...

Страница 2: ...ception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one of the following measures Reorient or relocate the receiving antenn...

Страница 3: ...nnection 2 Management Software 2 About Dynamic Host Control Protocol DHCP 3 About Features and Configuration 4 Hardware Configuration 4 Installation Instructions 6 Assigning IP Information 7 Software...

Страница 4: ...0 km Requires SFP I55 Extended Diagnostic Module NOTE Single strand versions SS display the transmit frequency in the Media 2 column 53 Safety Certifications UL CUL Listed to Safety of Information Tec...

Страница 5: ...g with EtherType TPID selection Remote monitoring and automatic alarms Bandwidth limiting The Host Remote pair configuration provides the following features Extends any 10 100 Mbps Ethernet based VLAN...

Страница 6: ...t and is accessed by using the included RJ 45 to DB 9 adapter The serial connection provides access the Managed Media Converter module configuration screens these configuration screens are also access...

Страница 7: ...nits in Host Remote applications and then reconfiguring all of the settings 3 iConfig Utility iConfig is a configuration utility in iView that lets you quickly and easily complete the first stages of...

Страница 8: ...must be selected using DIP switches These feature selections include the following Enable Disable management on each port DIP switches 1 2 and 3 Configure the module to be either a Standalone a Host o...

Страница 9: ...traffic passes between Optics and Data port EXCEPT what has been defined as the Management Domain The Management Domain can either be defined as untagged traffic or traffic with a specified VLAN ID I...

Страница 10: ...ve screw The Managed Media Converter module includes on board SNMP logic When installed in an iMediaChassis manage the Managed Media Converter module from the chassis by using the Unified Management A...

Страница 11: ...tall a 100 Mbps speed SFP Many SFPs including those from Black Box feature enhanced diagnostics capabilities with a Digital Diagnostics Monitoring Interface DDMI DDMI statistics provide real time acce...

Страница 12: ...UPLINK port except for the device s management traffic When in Loopback mode the Managed Media Converter module stops the OPTICS or UPLINK port traffic from continuing on out of the DATA port Address...

Страница 13: ...0 VLAN 32 0 0 VLAN 11 0 0 VLAN 22 0 0 Valid Vlan IDs are between 1 and 4094 Valid priorities are between 0 and 7 Type S or F3 to save the changes Type Q or F4 to quit and cancel changes Transparent Mo...

Страница 14: ...lect the TPID for the Extra Tag 1 8100 2 9100 3 9200 Extra Tag TPID 1 8100 5 On the Host Managed Media Converter module enter Y in the Are Extra Tags left on the Data Port field to only accept the Ext...

Страница 15: ...ort N Select the TPID for the Extra Tag 1 8100 2 9100 3 9200 Extra Tag TPID 1 8100 TRANSPARENT MODE SETUP Is a VLAN tag required on Management packets Y Do you want to enter the Extra Tag mode Enter Y...

Страница 16: ...N ID 7 as management g Type reboot Now the Managed Media Converter is configured to pass all data between the OPTICS or UPLINK and DATA ports except that which is tagged with VLAN ID 7 All data tagged...

Страница 17: ...Tag is 7 Management Priority is 0 e Make sure the Are VLAN Tags required on the EXT Port field is set to N TRANSPARENT MODE SETUP Is a VLAN tag required on Management packets Y Do you want to enter th...

Страница 18: ...TE 39 Now the Managed Media Converter is configured to pass only tagged data between the OPTICS or UPLINK and DATA ports All untagged data is considered management traffic and passes from the OPTICS o...

Страница 19: ...passes between Optics and Data port EXCEPT what has been defined as the Management Domain The Management Domain can either be defined as untagged traffic or traffic with a specified VLAN ID In Transpa...

Страница 20: ...air 2 TX LinkLoss detects the fault and disables the OPTICS or UPLINK port 3 FX LinkLoss detects the fiber loss and disables the DATA port The link fault is passed through the media conversion and is...

Страница 21: ...can also be performed using a Telnet session You can only use one Telnet session at a time There are three levels of Telnet account access User View status change own password and reboot Operator User...

Страница 22: ...connected device Press Enter after each You can also assign a default gateway to allow the unit to be visible beyond the local network press Enter to skip When finished press Enter then type reboot f...

Страница 23: ...e a new community string go to the main configuration screen and press C Enter the name of the new community up to 16 characters no spaces and press Enter Then type one of the following to assign the...

Страница 24: ...you can launch a console session through the serial port and type in the command cleandb If both the serial and the iConfig passwords are forgotten you must contact technical support Ending Your Sess...

Страница 25: ...two levels of cleandb The first level resets the Telnet iConfig password and all of the SNMP database values The second level additionally resets the IP address IP Subnet Gateway VLAN settings CLI com...

Страница 26: ...FXLinkLoss Only Enabled TXLinkLoss Only Enabled FiberAlert Plus FXLinkLoss Enabled FiberAlert Plus TXLinkLoss Enabled TXLinkLoss Plus FXLinkLoss Enabled TXLinkLoss FXLinkLoss FiberAlert Enabled Fiber...

Страница 27: ...trol Settings Unit FlowControl Disable FlowControl Globally Unit FiberAlert TXLinkLoss Plus FXLinkLoss Enabled Unit LoopBack No LoopBack Normal Traffic Mode Unit Max FrameSz Oversized Frames 1536 802...

Страница 28: ...management isolation and is not recommended for normal use This section describes the telnet serial port screens and fields available for configuring the Managed Media Converter modes 29 In the above...

Страница 29: ...0 0 VLAN 25 0 0 VLAN 4 0 0 VLAN 15 0 0 VLAN 26 0 0 VLAN 5 0 0 VLAN 16 0 0 VLAN 27 0 0 VLAN 6 0 0 VLAN 17 0 0 VLAN 28 0 0 VLAN 7 0 0 VLAN 18 0 0 VLAN 29 0 0 VLAN 8 0 0 VLAN 19 0 0 VLAN 30 0 0 VLAN 9 0...

Страница 30: ...a Tagging Enter N if you do not want Extra Tags N Are VLAN Tags required on the EXT Port N Type S or F3 to save the new information Type Q of F4 to quit and cancel changes Reboot is required for any c...

Отзывы: